Dropping Point Tester (Air bath) LDPT-A11

Labtron LDPT-A11 is designed and made as per the “Test Methods for Dropping Point of Lubricating Grease and Solid Hydrocarbon” ASTM D566.

  • Beaker quantity
    Ambient temperature ≤ 35 ℃
    Relative humidity ≤ 85 %
    Thermometer Measurement range
    Thermometer Scale division
    Thermometer Immersion depth
    Thermometer Total length
    Grease cup Material
    Grease cup Inner diameter
    Grease cup Orifice
    Grease cup Height
    Test tube Material
    Test tube Inner diameter
    Heater
    Stirring motor
    Dimensions
    Heating power of electric furnace 250 W × 2
    Total power consumption ≤ 700 W
    Power supply AC 220 V ± 10 %, 50 Hz
    • Desktop structure
    • Controlled by bidirectional silicon controlled rectifier
    • Double sample working style. It can do parallel test for two samples at a time
  • It is used to determine dropping point of lubricating grease and hydrocarbon over 100 ℃

Dropping Point Tester (Oil Bath) LDPT-A10

  • 600 mlBeaker quantity
  • (-10) °C ~ 40 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • (-5) °C ~ 300 °CThermometer Measurement range

Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11

  • Two samples or a group of parallel samplesTest bomb
  • 37.8 °CBath temperature
  • 0.1 °CTemperature controlling accuracy
  • 500 × 560 × 680 mm, 950 × 540 × 720 mmDimensions

Vapor Pressure Tester (REID METHOD) LVPT-C10

  • RT ~ 90 °COperation temperature of water bath
  • ± 0.1 °CTemperature controlling accuracy
  • 550 × 520 × 102 mmDimensions
  • ± 0.4 % kPaPressure meter accuracy
Automatic Softening Point Tester LSPT-A10
  • 32 ℃ to 160 ℃Measurement range
  • 35 °CAmbient temperature
  • 0.01 ℃Temperature resolution
  • 1000 mLBeaker volume
Rotational Viscometer LRV-A10
  • 10 ~ 2000000 MPa•sViscosity measurement range
  • 5 °C ~ 35 °CAmbient temperature
  • Not more than 80 %Ambient humidity
  • Four spindles of No.1 ~ 4Spindles

Automatic Tag Closed Flash Point Tester LACF-A10

  • -50 to 70°CExperimental temperature range
  • 50 mlTest sample volume
  • 10 to 40°CAmbient temperature range
  • ≤ 85%Humidity

Cleveland Open Cup Flash Point Tester LOFP-A11

  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature
Open Cup Flash Point Tester LOFP-A10
  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity
Automatic COC Flash & Fire Point Tester LOFP-B10
  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale