Automatic PMCC Flash Point Tester LCFP-A13

LCFP-A13 is designed with RS-323 and 485 computer ports which can calibrate the effect of barometric pressure to the test and calculate the modified value. It modifies system deviation automatically and can simulate and show temperature-time curve. It is designed as per “Test Methods for Flash Point of Petroleum Products (Closed Cup Methods)” ASTM D93.

  • Ambient temperature 10 °C ~ 40 ℃
    Relative humidity ≤ 80 %
    Ignition Mode electron igniter / gas flame
    Temperature range Room Temperature ~ 300 ℃
    Aperture of ignition device
    Standard oil cup-Inner diameter
    Standard oil cup- Depth
    Standard oil cup- Depth of Marked line on the oil cup
    Standard oil cup-Oil sample cubage
    Stirring speed
    Stirring blade
    Sample temperature rising rate
    Measurement Range Room Temperature ~ 300 ℃
    Flash Point
    Resolution 0.1 ℃
    Repeatability ≤ 2 ℃
    Reproducibility ≤ 4 ℃
    Accuracy 0.005
    Precision
    Gas Flame
    Heating power
    Dimension
    Total Power Consumption 300 W
    Power supply AC 220 V ± 10 %, 50 Hz
    Net Weight
    • Predetermined temperature, sample serial number, atmospheric pressure, test data and other parameters
    • Modifies test data, test time, and other parameters
    • LCD display
    • Electron igniter for flame ignition
    • Effective wind cooling function
    • It can save test data of 100 groups
  • It is used to determine the flash point of diesel and other fuel types in petrochemical analysis, flavors in food testing, paints in materials testing, and waste removal for environmental analysis

Automatic PMCC Flash Point Tester LCFP-A11

  • 10 °C ~ 40 °CAmbient temperature
  • ≤ 80 %Relative humidity
  • Ambient Temperature ~ 250 °CMeasurement Range
  • Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °CFlash Point

PMCC Flash Point Tester LCFP-A10

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °CTemperature range
  • 0.8 mmAperture of ignition device

Automatic Softening Point Tester LSPT-A10

  • 32 ℃ to 160 ℃Measurement range
  • 35 °CAmbient temperature
  • 0.01 ℃Temperature resolution
  • 1000 mLBeaker volume

Density Tester LDMT-A10

  • Ф300 × 380 mmCubage of bath
  • 0 °C ~ 100 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
  • Industrial platinum resistance, Pt100Temperature sensor
Existent Gum Tester LEGT- B31
  • Aluminum block bath, φ260 × 130 mmEvaporation bath type and size
  • 3 piecesHoles for testing
  • φ51 × 70 mmSize of holes for testing cylinder
  • Flow meterFlow rate display
Existent Gum Tester LEGT- B32
  • Aluminum bath φ260 × 130 mmEvaporation bath type and size
  • 5 piecesHoles for testing
  • φ51 × 70 mmSize of holes for testing cylinder
  • 160 ℃ ~ 165℃Working temperature

Existent Gum Tester LEGT- B30

  • Oil bathBath type
  • 5000 ml ± 50 mlBath capacity
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity

Constant Temperature Needle Penetration Tester LTNP-A10

  • 0 to 700 taper degree (digital display table 0-70 mm)Measuring range
  • Timing error is less than ±0.1 sTiming device
  • 0.01 mm Resolution
  • ±1 cone insertion degreeNeedle insertion accuracy
Octane Number and Cetane Number Tester LOCT-A10
  • 86.0 to 105.0/MON Measuring Range For Aviation Gasoline
  • National standard: 65.0 to 110.0/RON
    National-V standard: 70 to 115.0/RON
    Blended gasoline: 75.0 to 120.0/RON
    Light gasoline: 50.0 to 85.0 /MON
    Isomerized gasoline: 85.0 to 120.0/RON
    Arene gasoline: 90.0 to 120.0/RON
     Measuring Range For Gasoline For Motor Vehicles
  • E93: 92.0 to 95.0/RON
    E97: 95.0 to 99.0/RON
    Judgement: 60.0 to 120.0/RON
     Measuring Range For Ethanol
  • Cetane number: 25 to 75/CN
    Cetane index: 20 to 80/CI
    Measuring Range For Automobile Diesel Fuels
Portable Octane Number and Cetane Meter LOCT-A20
  • motor gasoline and dieselMeasurement item
  • 40 to 120measurement unit of octane is ON
  • ± 0.5 maxPermissible error of octane
  • ± 0.2 maxFluctuate range of octane