Automatic Softening Point Tester LSPT-A10

Automatic softening point tester LSPT-A10 is a bench top microprocessor controlled analytical unit that determines the softening point of two samples at once. Operated via touch panel it uses ball and ring apparatus for reliable detection. Designed as per Test methods of Bitumen and Bituminous Mixture for Highway Engineering and ASTM D36 Standard test method for Softening of Bitumen (Ring-and-Ball Apparatus) it is ideal for determining the softening points of petroleum asphalts, coal pitch, liquid petroleum asphalt, etc.

  • Measurement range 32 ℃ to 160 ℃
    Ambient temperature 35 °C
    Temperature resolution 0.01 ℃
    Beaker volume 1000 mL
    Relative humidity ≤85%
    Heating power 600 W
    Total power consumption ≤ 700 W
    Power supply AC 220V ( -5 % ~ 10 % ), 50 Hz
    • Microprocessor controlled compact structure
    • Automatic stirring, linear heating and test result detection
    • High temperature resistant glass made beaker
    • LCD display
    • Dual sample simultaneous softening point detection
    • Automatic print of test results
    • Light touch panel
    • Connects easily to PC
  • Used in asphalt manufacturing companies, highway and bridge construction companies, laboratories, universities, scientific research institutes, etc.

  • Sr. No Name Unit Quantity
    1 Automatic Softening Point Tester Set 1
    2 Steel ball locator Piece 2
    3 Steel ball Piece 2
    4 Shoulder ring Piece 2
    5 Beaker Piece 1
    6 Stirring bar Piece 1
    7 Temperature sensor and cable Piece 1
    8 W-line Piece 1
    9 Fuse 6A( Ф 5 × 20 ) Piece 2
    10 Software CD Piece 1
    11 Printer paper Roll 1
    12 Glycerin ( 1000 ml ) Bottle 2
    13 Softening point thermometer( 30 ~ 180 )℃,scale mark 0.5 ℃ Piece 1
    14 Bracket box Piece 1
    15 Thermometer stopper (3#) Piece 1
    16 Stopping ring for thermometer (1#) Piece 2

Automatic PMCC Flash Point Tester LCFP-A11

  • 10 °C ~ 40 °CAmbient temperature
  • ≤ 80 %Relative humidity
  • Ambient Temperature ~ 250 °CMeasurement Range
  • Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °CFlash Point

Automatic PMCC Flash Point Tester LCFP-A13

  • 10 °C ~ 40 ℃Ambient temperature
  • ≤ 80 %Relative humidity
  • electron igniter / gas flameIgnition Mode
  • Room Temperature ~ 300 ℃Temperature range
PMCC Flash Point Tester LCFP-A10
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °CTemperature range
  • 0.8 mmAperture of ignition device
Specific Gravity Tester LSGT-A10
  •  4000 ml × 2Vessel Volume
  • 160 WPower of Vacuum pump
  • 3.7 kPa(27.75 mmHg)Negative power
  • 30 WPower of shaking machine

Mercaptan Sulfur Tester LMST-A10

  • (0 to ±1999.5) MvPotential measuring range
  • 0.1 % ±0.5 mVIntrinsic error
  • Ri ≥1 × 1012 ΩInput impedance
  • 10 mLBurette capacity

Kinematics Viscometer LKV-A11

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A13
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A12
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Aniline Point Tester LAPT-A11

  • ≤ 0.5 ℃Temperature controlling accuracy
  • Room temperature ~ 200 ℃Temperature controlling range
  • 5 VPower supply for illumination
  • 2 kWPower of motor

Aniline Point Tester LAPT-A10

  • Room temperature ~ 150°CMeasurement range
  • 0 ~ 1200 r / minStirring speed
  • 25 WHeating power
  • 360 × 250 × 545 mmInterior Dimension