Vapor Pressure Tester (REID METHOD) LVPT-C10

Labtron LVPT-C10 is designed with pressure gauge, digital display temperature controller and pump loop. It is manufactured and made as per the International Standard ASTM D323 “Test Methods for Vapor Pressure of Petroleum Products (Reid Methods)”.

  • Test bomb
    Operation temperature of water bath RT ~ 90 °C
    Bath temperature
    Temperature controlling accuracy ± 0.1 °C
    Dimensions 550 × 520 × 102 mm
    Pressure meter accuracy ± 0.4 % kPa
    Heating power of water bath 1600 W
    Total power consumption ≤ 1700 W
    Power supply AC 220 V ± 10 %, 50 Hz
    Relative humidity ≤ 85 %
    Ambient temperature (-10) °C ~ 35 °C
    Pressure range
    • Attractive appearance and easy to operate
    • Pressure gauge with big dial plate
    • Digital display temperature controller
    • Long lasting, safe and reliable
    • Two groups of experiments simultaneously
    • High work efficiency and precision
    • Pump loop provided, string regularly and noiseless
  • It is mainly used in petroleum, chemical and development industry. It is suitable to determine vapor pressure of gasoline, volatile petroleum and other volatile petroleum products.

Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11

  • Two samples or a group of parallel samplesTest bomb
  • 37.8 °CBath temperature
  • 0.1 °CTemperature controlling accuracy
  • 500 × 560 × 680 mm, 950 × 540 × 720 mmDimensions

Automatic Bomb Calorimeter LABC-B10

  • IsoperibolCalorimeter type
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & loweringOxygen filling
  • 250 mlBomb volume
  • < 8 min full test process: <10 minAnalysis time

Automatic Bomb Calorimeter LABC-A10

  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • The outer barrel temperature is constantOperation Mode
Automatic Bomb Calorimeter LABC-A11
  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant modeOperation Mode
Rotational Viscometer LRV-A10
  • 10 ~ 2000000 MPa•sViscosity measurement range
  • 5 °C ~ 35 °CAmbient temperature
  • Not more than 80 %Ambient humidity
  • Four spindles of No.1 ~ 4Spindles

Penetrometer LMPT-A12

  • {"Measurement range":"0 to 600 penetration scale","Timing controller":"5 sec or 60 sec","Time accuracy":"\u00b1 0.1 seconds","Resolution":"0.1 penetration","Penetration accuracy":"\u00b1 1 penetration","Weight of standard needle":"2.5 \u00b1 0.05 g","Dimensions (W \u00d7 L \u00d7 H)":"700 \u00d7 400 \u00d7 750 mm","Weight":"30 kg"}Penetrometer
  • {"Bath volume":"3.5 L","Temperature range":"5 \u00b0C to 60 \u00b0C","Temperature accuracy":"\u00b1 0.1 \u00b0C","Circulatory water quantity":"3 L\/minute","Pump Lift":"2 m","Power consumption":"1200 W","Power supply":"AC 220V \u00b1 10 %, 50 Hz","Dimensions (W \u00d7 L \u00d7 H)":"600 \u00d7 400 \u00d7 650 mm","Weight":"40 kg"}Circulatory Water Bath

Penetrometer LMPT-A11

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec or 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution
Penetrometer LMPT-A10
  • 0 to 600 penetration scaleMeasurement range
  • 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution
Automatic Softening Point Tester LSPT-A10
  • 32 ℃ to 160 ℃Measurement range
  • 35 °CAmbient temperature
  • 0.01 ℃Temperature resolution
  • 1000 mLBeaker volume

Automatic Dielectric Tester LADT-A10

  • 2.0 kVACapacity
  • 2 k V/ sSpeed of voltage increase
  • 0.01Voltage inspection accuracy
  • < 0.1 kVBreakdown sensitivity