Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11

Labtron LVPT-C10 is designed with pressure gauge, digital display temperature controller and pump loop. It is manufactured and made as per the International Standard ASTM D323 “Test Methods for Vapor Pressure of Petroleum Products (Reid Methods)”.

  • Test bomb Two samples or a group of parallel samples
    Operation temperature of water bath
    Bath temperature 37.8 °C
    Temperature controlling accuracy 0.1 °C
    Dimensions 500 × 560 × 680 mm, 950 × 540 × 720 mm
    Pressure meter accuracy
    Heating power of water bath 1400 W
    Total power consumption ≤ 1500 W
    Power supply AC 220 V ± 10 %
    Relative humidity ≤ 85 %
    Ambient temperature (-10) °C ~ 35 °C
    Pressure range 0 ~ 200 kPa
    • Performs two experiments at same time
    • Easy operation with clear display
    • Stores high capacity of historical data
    • Long working life
    • Simple operation with elegant structure
  • It is widely used in petroleum, chemical and development industry. It is suitable to determine vapor pressure of gasoline, volatile petroleum and other volatile petroleum products.

Vapor Pressure Tester (REID METHOD) LVPT-C10

  • RT ~ 90 °COperation temperature of water bath
  • ± 0.1 °CTemperature controlling accuracy
  • 550 × 520 × 102 mmDimensions
  • ± 0.4 % kPaPressure meter accuracy

Mercaptan Sulfur Tester LMST-A10

  • (0 to ±1999.5) MvPotential measuring range
  • 0.1 % ±0.5 mVIntrinsic error
  • Ri ≥1 × 1012 ΩInput impedance
  • 10 mLBurette capacity

X-ray Fluorescence Sulfur in Oil Analyzer LST-A10

  • 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)Sample quantity
  • 60, 120, 240, 300, and 600 s at randomMeasurement time
  • 7 ppm to 5 %Measurement range
  • < 0.029 (S + 0.6)Repeatability
Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11
  • Not less than 150 L / hAir flow rate
  • 99 min 59 s (100 min)Max. Preset time
  • Φ22 mmChamber diameter of oven
  • 1400 W × 2Heating power of oven
Oxygen Bomb Calorimeter LBC-C21
  • 10 ℃ ~ 35 ℃Temperature controlling range
  • 0.001 ℃Temperature resolution
  • 15 kJ / KMean value of heat capacity
  • 20 ℃ ± 5 ℃Ambient temperature

Oxygen Bomb Calorimeter LBC-C22

  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
  • 15 ~ 28 ℃Operation environment temperature

Oxygen Bomb Calorimeter LBC-C20

  • 14000 ~ 15000 J / KHeat capacity
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
Penetrometer LMPT-A12
  • {"Measurement range":"0 to 600 penetration scale","Timing controller":"5 sec or 60 sec","Time accuracy":"\u00b1 0.1 seconds","Resolution":"0.1 penetration","Penetration accuracy":"\u00b1 1 penetration","Weight of standard needle":"2.5 \u00b1 0.05 g","Dimensions (W \u00d7 L \u00d7 H)":"700 \u00d7 400 \u00d7 750 mm","Weight":"30 kg"}Penetrometer
  • {"Bath volume":"3.5 L","Temperature range":"5 \u00b0C to 60 \u00b0C","Temperature accuracy":"\u00b1 0.1 \u00b0C","Circulatory water quantity":"3 L\/minute","Pump Lift":"2 m","Power consumption":"1200 W","Power supply":"AC 220V \u00b1 10 %, 50 Hz","Dimensions (W \u00d7 L \u00d7 H)":"600 \u00d7 400 \u00d7 650 mm","Weight":"40 kg"}Circulatory Water Bath
Penetrometer LMPT-A11
  • 0 to 600 penetration scaleMeasurement range
  • 5 sec or 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Penetrometer LMPT-A10

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Octane Number and Cetane Number Tester LOCT-A10

  • 86.0 to 105.0/MON Measuring Range For Aviation Gasoline
  • National standard: 65.0 to 110.0/RON
    National-V standard: 70 to 115.0/RON
    Blended gasoline: 75.0 to 120.0/RON
    Light gasoline: 50.0 to 85.0 /MON
    Isomerized gasoline: 85.0 to 120.0/RON
    Arene gasoline: 90.0 to 120.0/RON
     Measuring Range For Gasoline For Motor Vehicles
  • E93: 92.0 to 95.0/RON
    E97: 95.0 to 99.0/RON
    Judgement: 60.0 to 120.0/RON
     Measuring Range For Ethanol
  • Cetane number: 25 to 75/CN
    Cetane index: 20 to 80/CI
    Measuring Range For Automobile Diesel Fuels
Portable Octane Number and Cetane Meter LOCT-A20
  • motor gasoline and dieselMeasurement item
  • 40 to 120measurement unit of octane is ON
  • ± 0.5 maxPermissible error of octane
  • ± 0.2 maxFluctuate range of octane