Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11

Labtron LVPT-C10 is designed with pressure gauge, digital display temperature controller and pump loop. It is manufactured and made as per the International Standard ASTM D323 “Test Methods for Vapor Pressure of Petroleum Products (Reid Methods)”.

  • Test bomb Two samples or a group of parallel samples
    Operation temperature of water bath
    Bath temperature 37.8 °C
    Temperature controlling accuracy 0.1 °C
    Dimensions 500 × 560 × 680 mm, 950 × 540 × 720 mm
    Pressure meter accuracy
    Heating power of water bath 1400 W
    Total power consumption ≤ 1500 W
    Power supply AC 220 V ± 10 %
    Relative humidity ≤ 85 %
    Ambient temperature (-10) °C ~ 35 °C
    Pressure range 0 ~ 200 kPa
    • Performs two experiments at same time
    • Easy operation with clear display
    • Stores high capacity of historical data
    • Long working life
    • Simple operation with elegant structure
  • It is widely used in petroleum, chemical and development industry. It is suitable to determine vapor pressure of gasoline, volatile petroleum and other volatile petroleum products.

Vapor Pressure Tester (REID METHOD) LVPT-C10

  • RT ~ 90 °COperation temperature of water bath
  • ± 0.1 °CTemperature controlling accuracy
  • 550 × 520 × 102 mmDimensions
  • ± 0.4 % kPaPressure meter accuracy

Automatic Softening Point Tester LSPT-A10

  • 32 ℃ to 160 ℃Measurement range
  • 35 °CAmbient temperature
  • 0.01 ℃Temperature resolution
  • 1000 mLBeaker volume

Mercaptan Sulfur Tester LMST-A10

  • (0 to ±1999.5) MvPotential measuring range
  • 0.1 % ±0.5 mVIntrinsic error
  • Ri ≥1 × 1012 ΩInput impedance
  • 10 mLBurette capacity
Foaming Characteristics Tester LFCT-A10
  • Ambient to 100°CTemperature Range
  • ± 0.1°CTemperature Precision
  • 94 mL ± 5 mL/min, with flowmetersAir Flow
  • 0 to 99 min 59 s, resolution 1 sTiming Unit
Density Tester LDMT-A10
  • Ф300 × 380 mmCubage of bath
  • 0 °C ~ 100 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
  • Industrial platinum resistance, Pt100Temperature sensor

Vapor Pressure Tester (REID METHOD) LVPT-C10

  • RT ~ 90 °COperation temperature of water bath
  • ± 0.1 °CTemperature controlling accuracy
  • 550 × 520 × 102 mmDimensions
  • ± 0.4 % kPaPressure meter accuracy

Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11

  • Two samples or a group of parallel samplesTest bomb
  • 37.8 °CBath temperature
  • 0.1 °CTemperature controlling accuracy
  • 500 × 560 × 680 mm, 950 × 540 × 720 mmDimensions