Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20 is a portable detector used for octane and cetane number measurement, based on theory of insulate magnetic permeability and electromagnetic induction. It offers 60 ×100 mm sensor and 15 hours operating time duration. The precise sensors can measure out parameters fluctuation of the tiny mediums, to get result of octane and cetane. The interface is use friendly with longer standby-cyclic charging battery. It has external cover with high strength, shock resistance and water, dust and moisture proof performance.

  • Measurement item motor gasoline and diesel
    measurement unit of octane is ON 40 to 120
    Permissible error of octane ± 0.5 max
    Fluctuate range of octane ± 0.2 max
    measurement unit of cetane is CN 20 to 100
    Permissible error of cetane ± 1 max
    Fluctuate range of cetane ± 0.5 max
    Measurement time ± ˂ 20
    Critical value for battery 2.5 V
    Sensor 60 ×100 mm
    Temperature -10˚C to 40˚C
    Humidity 30 % to 81 % RH
    Barometric pressure 64 to 106 kPa
    Measurement of octane standard ASTM D2699-86, ASTM D2700-86
    Measurement of cetane standard ASTM D4737-03
    Operation duration 15 h
    Display LED screen, printable result
    Power consumption 30 ma
    Weight 5 kg (max)
    • Measure both of gasoline octane value and diesel cetane value
    • Designed with larger screen display, Rapid and precise measurement
    • Sensor adopt full-sealed design with alloying metal
    • High strength, shock resistance and water/dust/moisture proof performance
    • Upper and lower limits pre-setting are available
    • Auto-off function save energy and realize low power consumption
    • Equipped with 4 reliable batteries for recycling charging
    • Measure the oil octane and cetane precise value rapidly and store large amount of data
  • Portable Octane Number and Cetane Meter is used in Research Octane Number (RON) of unleaded gasoline, ethanol blended gasoline, leaded gasoline and Cetane Number for diesel fuels.

Octane Number and Cetane Number Tester LOCT-A10

  • 86.0 to 105.0/MON Measuring Range For Aviation Gasoline
  • National standard: 65.0 to 110.0/RON
    National-V standard: 70 to 115.0/RON
    Blended gasoline: 75.0 to 120.0/RON
    Light gasoline: 50.0 to 85.0 /MON
    Isomerized gasoline: 85.0 to 120.0/RON
    Arene gasoline: 90.0 to 120.0/RON
     Measuring Range For Gasoline For Motor Vehicles
  • E93: 92.0 to 95.0/RON
    E97: 95.0 to 99.0/RON
    Judgement: 60.0 to 120.0/RON
     Measuring Range For Ethanol
  • Cetane number: 25 to 75/CN
    Cetane index: 20 to 80/CI
    Measuring Range For Automobile Diesel Fuels

Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

  • 2Samples
  • 30 LOil bath cubage
  • 30 °Angle between bomb and water surface
  • 100 ± 5 RPMSpeed of rotary assembly

Distillate Fuel Oil Oxidation Stability Tester LOST-D12

  • 8Samples
  • 100 ℃Temperature
  • 0.1 ℃Temperature controlling accuracy
  • 3 ± 0.3 L / H oxygenFlow meter
Transformer Oil Oxidation Stability Tester LOST-D11
  • 6Samples
  • Automatic digital temperatureTemperature controlling mode
  • Room temperature ~ 160 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
Constant Temperature Needle Penetration Tester LTNP-A10
  • 0 to 700 taper degree (digital display table 0-70 mm)Measuring range
  • Timing error is less than ±0.1 sTiming device
  • 0.01 mm Resolution
  • ±1 cone insertion degreeNeedle insertion accuracy

Automatic Bomb Calorimeter LABC-B10

  • IsoperibolCalorimeter type
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & loweringOxygen filling
  • 250 mlBomb volume
  • < 8 min full test process: <10 minAnalysis time

Automatic Bomb Calorimeter LABC-A10

  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • The outer barrel temperature is constantOperation Mode
Automatic Bomb Calorimeter LABC-A11
  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant modeOperation Mode
Existent Gum Tester LEGT- B32
  • Aluminum bath φ260 × 130 mmEvaporation bath type and size
  • 5 piecesHoles for testing
  • φ51 × 70 mmSize of holes for testing cylinder
  • 160 ℃ ~ 165℃Working temperature

Existent Gum Tester LEGT- B31

  • Aluminum block bath, φ260 × 130 mmEvaporation bath type and size
  • 3 piecesHoles for testing
  • φ51 × 70 mmSize of holes for testing cylinder
  • Flow meterFlow rate display

Existent Gum Tester LEGT- B30

  • Oil bathBath type
  • 5000 ml ± 50 mlBath capacity
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
Automatic Thermogravimetric Analyzer LTGA-A10
  • Room temperature to 1000 ºC Temperature range
  • 0.1 ºCTemperature resolution
  • ±0.1 ºCTemperature fluctuation
  • 1 ~ 80 ºC / minHeating rate