Existent Gum Tester LEGT- B31

Labtron LEGT-B31 is fabricated with heating bath and air compressor to be more accurate and meet the industrial requirements. The instrument is designed and made as per ASTM D381-12 “Test Methods for Existent Gum of Vehicle Gasoline and Aviation Fuels (Jet Evaporation Methods)”.

  • Bath type
    Bath capacity
    Ambient temperature
    Relative humidity
    Temperature controlling range
    Temperature controlling accuracy
    Heating type
    Evaporation bath type and size Aluminum block bath, φ260 × 130 mm
    Constant temperature bath
    Holes for testing 3 pieces
    Size of holes for testing cylinder φ51 × 70 mm
    Flow rate display Flow meter
    Working temperature 60 ℃ to 165 ℃
    Temperature controlling methods Automatic temperature controlling
    Temperature display Digitally displayed
    Working pressure for decompression valve 0.035 MPa
    Gas source Compressed air > 110 L/min
    Air flow rate at jet nozzle
    Dimension 550 x 370 x 335 mm
    Total power consumption
    Heating power
    Power supply AC 220 V ± 10 %, 50 Hz; 2.5 kW
    • Independent flow meter use to adjust jet flows
    • Designed heating bath and gas circuit
    • Evaporation rate is good
    • Determination of three sample can be done simultaneously
  • It is widely used in petroleum, chemical, automobile and development industry. It is also suitable for determining the existent gum content of aviation gasoline and motor gasoline.

Existent Gum Tester LEGT- B32

  • Aluminum bath φ260 × 130 mmEvaporation bath type and size
  • 5 piecesHoles for testing
  • φ51 × 70 mmSize of holes for testing cylinder
  • 160 ℃ ~ 165℃Working temperature

Existent Gum Tester LEGT- B30

  • Oil bathBath type
  • 5000 ml ± 50 mlBath capacity
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity

Coulometric Karl Fischer Titrator LWT-A30

  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed

Water Content Tester LWT-A10

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination
Water Content Tester LWT-A11
  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination
Vapor Pressure Tester (REID METHOD) LVPT-C10
  • RT ~ 90 °COperation temperature of water bath
  • ± 0.1 °CTemperature controlling accuracy
  • 550 × 520 × 102 mmDimensions
  • ± 0.4 % kPaPressure meter accuracy

Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11

  • Two samples or a group of parallel samplesTest bomb
  • 37.8 °CBath temperature
  • 0.1 °CTemperature controlling accuracy
  • 500 × 560 × 680 mm, 950 × 540 × 720 mmDimensions

Density Tester LDMT-A10

  • Ф300 × 380 mmCubage of bath
  • 0 °C ~ 100 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
  • Industrial platinum resistance, Pt100Temperature sensor
Open Cup Flash Point Tester LOFP-A10
  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity
Automatic COC Flash & Fire Point Tester LOFP-B10
  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability

Cleveland Open Cup Flash Point Tester LOFP-A11

  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature

PMCC Flash Point Tester LCFP-A10

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °CTemperature range
  • 0.8 mmAperture of ignition device
Automatic PMCC Flash Point Tester LCFP-A11
  • 10 °C ~ 40 °CAmbient temperature
  • ≤ 80 %Relative humidity
  • Ambient Temperature ~ 250 °CMeasurement Range
  • Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °CFlash Point
Automatic PMCC Flash Point Tester LCFP-A13
  • 10 °C ~ 40 ℃Ambient temperature
  • ≤ 80 %Relative humidity
  • electron igniter / gas flameIgnition Mode
  • Room Temperature ~ 300 ℃Temperature range