Foaming Characteristics Tester LFCT-A10

Foaming Characteristics Tester LFCT-A10 is a benchtop unit and offers ambient to 100°C temperature range with precision of ± 0.1°C. The instrument is distributed into two groups of baths at 24°C and 93.5°C and separate control for temperature as well as flow rate. Equipped with gas diffusion head, oil-free air pump and air filter. Allows determination of the foaming characteristics of lubricating oils at specific temperatures by empirically rating the foaming tendency and the foam stability.

  • Temperature Range Ambient to 100°C
    Temperature Precision ± 0.1°C
    Air Flow 94 mL ± 5 mL/min, with flowmeters
    Timing Unit 0 to 99 min 59 s, resolution 1 s
    Control System Single chip microcontroller
    Heating Power 2000 W
    Power Supply AC 220 V ± 10 %, 50 Hz
    • Equipped with bath of 24°C and 93.5°C
    • Touch-screen colored LCD display for ease of monitoring
    • Separate control for flow rate
    • Automatic buzzer alarm for completion of test
    • Easy to use, long life span, safe and reliable
    • Confirms to international standards of ASTM D892, ISO 6247
  • Foaming Characteristics Tester is used to determine the foaming stability and tendency of lubricating oils at temperature up to 100°C. It finds application in petroleum industry, synthetic oil processing units etc.

  • Sr. No Name of the Accessory Specification Quantity
                      1.           Main Unit 1 Set
                      2.           Foaming Test Cylinder 1000 ml 4 Pieces
                      3.           Air Flow Rod 4 Pieces
                      4.           Thermometer 0 to 50°C 1 Piece
                      5.           Thermometer 50 to 100°C 1 Piece
                      6.           Diffusion Head 2 Pieces
                      7.           Silicone Hose 2 Meters
                      8.           Rubber Plug 4 Pieces
                      9.           Portable Cooler 1 Set
                    10.         Air Pump 1 Set
                    11.         Air Dryer 1 Set
                    12.         Fuse 2 Pieces

Aniline Point Tester LAPT-A10

  • Room temperature ~ 150°CMeasurement range
  • 0 ~ 1200 r / minStirring speed
  • 25 WHeating power
  • 360 × 250 × 545 mmInterior Dimension

Aniline Point Tester LAPT-A11

  • ≤ 0.5 ℃Temperature controlling accuracy
  • Room temperature ~ 200 ℃Temperature controlling range
  • 5 VPower supply for illumination
  • 2 kWPower of motor
Specific Gravity Tester LSGT-A10
  •  4000 ml × 2Vessel Volume
  • 160 WPower of Vacuum pump
  • 3.7 kPa(27.75 mmHg)Negative power
  • 30 WPower of shaking machine
Automatic Tag Closed Flash Point Tester LACF-A10
  • -50 to 70°CExperimental temperature range
  • 50 mlTest sample volume
  • 10 to 40°CAmbient temperature range
  • ≤ 85%Humidity

PMCC Flash Point Tester LCFP-A10

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °CTemperature range
  • 0.8 mmAperture of ignition device

Automatic PMCC Flash Point Tester LCFP-A11

  • 10 °C ~ 40 °CAmbient temperature
  • ≤ 80 %Relative humidity
  • Ambient Temperature ~ 250 °CMeasurement Range
  • Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °CFlash Point
Automatic PMCC Flash Point Tester LCFP-A13
  • 10 °C ~ 40 ℃Ambient temperature
  • ≤ 80 %Relative humidity
  • electron igniter / gas flameIgnition Mode
  • Room Temperature ~ 300 ℃Temperature range
Copper Strip Corrosion Tester LRCT-A13
  • 4 piecesSample hole
  • 4 to 12 piecesSample quantity
  • Room temperature to 35 °CAmbient temperature
  • Room temperature to 100°CTemperature controlling range

Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10

  • 2 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 10 to 35°CAmbient temperature
  • Room Temperature to 100°CTemperature controlling range

Lubricating Oil Rust Characteristics Tester LRCT-A11

  • 4 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 1000 ± 50 rpmSpeed for sample stirring
  • Room temperature to 35°CAmbient temperature