Foaming Characteristics Tester LFCT-A10

Foaming Characteristics Tester LFCT-A10 is a benchtop unit and offers ambient to 100°C temperature range with precision of ± 0.1°C. The instrument is distributed into two groups of baths at 24°C and 93.5°C and separate control for temperature as well as flow rate. Equipped with gas diffusion head, oil-free air pump and air filter. Allows determination of the foaming characteristics of lubricating oils at specific temperatures by empirically rating the foaming tendency and the foam stability.

  • Temperature Range Ambient to 100°C
    Temperature Precision ± 0.1°C
    Air Flow 94 mL ± 5 mL/min, with flowmeters
    Timing Unit 0 to 99 min 59 s, resolution 1 s
    Control System Single chip microcontroller
    Heating Power 2000 W
    Power Supply AC 220 V ± 10 %, 50 Hz
    • Equipped with bath of 24°C and 93.5°C
    • Touch-screen colored LCD display for ease of monitoring
    • Separate control for flow rate
    • Automatic buzzer alarm for completion of test
    • Easy to use, long life span, safe and reliable
    • Confirms to international standards of ASTM D892, ISO 6247
  • Foaming Characteristics Tester is used to determine the foaming stability and tendency of lubricating oils at temperature up to 100°C. It finds application in petroleum industry, synthetic oil processing units etc.

  • Sr. No Name of the Accessory Specification Quantity
                      1.           Main Unit 1 Set
                      2.           Foaming Test Cylinder 1000 ml 4 Pieces
                      3.           Air Flow Rod 4 Pieces
                      4.           Thermometer 0 to 50°C 1 Piece
                      5.           Thermometer 50 to 100°C 1 Piece
                      6.           Diffusion Head 2 Pieces
                      7.           Silicone Hose 2 Meters
                      8.           Rubber Plug 4 Pieces
                      9.           Portable Cooler 1 Set
                    10.         Air Pump 1 Set
                    11.         Air Dryer 1 Set
                    12.         Fuse 2 Pieces

Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

  • (-10)℃ ~ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 31.0 ~ 32.0 mmSample cup Inner diameter
  • 1.0 ~ 1.5 mmSample cup Wall thickness

Solidifying Point Tester LLTT-A13

  • ± 0.5 ℃Temperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • Two holes in one trough, and same temperatureCold trough
  • ≤ 30 ℃Ambient temperature
Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15
  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity
Constant Temperature Needle Penetration Tester LTNP-A10
  • 0 to 700 taper degree (digital display table 0-70 mm)Measuring range
  • Timing error is less than ±0.1 sTiming device
  • 0.01 mm Resolution
  • ±1 cone insertion degreeNeedle insertion accuracy

Penetrometer LMPT-A12

  • {"Measurement range":"0 to 600 penetration scale","Timing controller":"5 sec or 60 sec","Time accuracy":"\u00b1 0.1 seconds","Resolution":"0.1 penetration","Penetration accuracy":"\u00b1 1 penetration","Weight of standard needle":"2.5 \u00b1 0.05 g","Dimensions (W \u00d7 L \u00d7 H)":"700 \u00d7 400 \u00d7 750 mm","Weight":"30 kg"}Penetrometer
  • {"Bath volume":"3.5 L","Temperature range":"5 \u00b0C to 60 \u00b0C","Temperature accuracy":"\u00b1 0.1 \u00b0C","Circulatory water quantity":"3 L\/minute","Pump Lift":"2 m","Power consumption":"1200 W","Power supply":"AC 220V \u00b1 10 %, 50 Hz","Dimensions (W \u00d7 L \u00d7 H)":"600 \u00d7 400 \u00d7 650 mm","Weight":"40 kg"}Circulatory Water Bath

Penetrometer LMPT-A10

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution
Penetrometer LMPT-A11
  • 0 to 600 penetration scaleMeasurement range
  • 5 sec or 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution
Cleveland Open Cup Flash Point Tester LOFP-A11
  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature

Open Cup Flash Point Tester LOFP-A10

  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity

Automatic COC Flash & Fire Point Tester LOFP-B10

  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability
Octane Number and Cetane Number Tester LOCT-A10
  • 86.0 to 105.0/MON Measuring Range For Aviation Gasoline
  • National standard: 65.0 to 110.0/RON
    National-V standard: 70 to 115.0/RON
    Blended gasoline: 75.0 to 120.0/RON
    Light gasoline: 50.0 to 85.0 /MON
    Isomerized gasoline: 85.0 to 120.0/RON
    Arene gasoline: 90.0 to 120.0/RON
     Measuring Range For Gasoline For Motor Vehicles
  • E93: 92.0 to 95.0/RON
    E97: 95.0 to 99.0/RON
    Judgement: 60.0 to 120.0/RON
     Measuring Range For Ethanol
  • Cetane number: 25 to 75/CN
    Cetane index: 20 to 80/CI
    Measuring Range For Automobile Diesel Fuels
Portable Octane Number and Cetane Meter LOCT-A20
  • motor gasoline and dieselMeasurement item
  • 40 to 120measurement unit of octane is ON
  • ± 0.5 maxPermissible error of octane
  • ± 0.2 maxFluctuate range of octane