Open Cup Flash Point Tester LOFP-A10

Labtron LOFP-A10 is designed with higher precision and perfection to meet its wide range of applications. It is incorporated with advanced and reasonable temperature control features.

  • Thermometer 0 ℃ ~ 360 °C
    Scale Division 1 °C
    Spout Aperture
    Ambient Temperature ≤ 35 °C
    Relative Humidity ≤ 85 %
    Temperature Measurement- Full Scale
    Temperature Measurement- Repeatability
    Temperature Measurement- Reproducibility
    Temperature Measurement- Resolution
    Test accuracy
    Reappearance
    Graduation
    Outer Crucible-Material Carbon structural steel
    Outer Crucible-Diameter Of Upper Opening Φ100 ± 5 mm
    Outer Crucible-Height 50 ± 5 mm
    Outer Crucible-Diameter Of Bottom Φ56 ± 2 mm
    Inner Crucible-Material Carbon structural steel
    Inner Crucible-Diameter Of Upper Opening Φ64 ± 1 mm
    Inner Crucible-Height 47 ± 1 mm
    Inner Crucible-Diameter Of Bottom Φ38± 1 mm
    Inner Crucible-Scale Line 12mm away from the rim of upper opening and 18mm away from the rim of upper opening
    Precision
    Gas Tube Φ0.8 ~ Φ1 mm
    Flame 3 to 4 mm
    Heater Heated by an electric furnace
    Heating Power 1000W
    Dimensions 410 x 360 x 240 mm
    Power Consumption ≤ 1100 W
    Power Supply AC 220 V ± 10 %, 50Hz
    =#REF!
    • Adjustable heating power
    • Electric current meter to display power
    • Tiny desktop structure
    • Easy to operate
  • Used to determine the flash point and fire point of lubricating oil and dark petroleum products

Cleveland Open Cup Flash Point Tester LOFP-A11

  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature

Automatic COC Flash & Fire Point Tester LOFP-B10

  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability

Automatic Cleveland Open Cup Flash Point Tester LOFP-A12

  • 10 ℃ ~ 40 °CAmbient Temperature
  • ≤ 80 %Relative Humidity
  • Ambient temperature to 300 °CTemperature Measurement- Full Scale
  • ≤ 8 °CTemperature Measurement- Repeatability

Automatic PMCC Flash Point Tester LCFP-A11

  • 10 °C ~ 40 °CAmbient temperature
  • ≤ 80 %Relative humidity
  • Ambient Temperature ~ 250 °CMeasurement Range
  • Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °CFlash Point

Automatic PMCC Flash Point Tester LCFP-A13

  • 10 °C ~ 40 ℃Ambient temperature
  • ≤ 80 %Relative humidity
  • electron igniter / gas flameIgnition Mode
  • Room Temperature ~ 300 ℃Temperature range
PMCC Flash Point Tester LCFP-A10
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °CTemperature range
  • 0.8 mmAperture of ignition device
Aniline Point Tester LAPT-A11
  • ≤ 0.5 ℃Temperature controlling accuracy
  • Room temperature ~ 200 ℃Temperature controlling range
  • 5 VPower supply for illumination
  • 2 kWPower of motor

Aniline Point Tester LAPT-A10

  • Room temperature ~ 150°CMeasurement range
  • 0 ~ 1200 r / minStirring speed
  • 25 WHeating power
  • 360 × 250 × 545 mmInterior Dimension

Specific Gravity Tester LSGT-A10

  •  4000 ml × 2Vessel Volume
  • 160 WPower of Vacuum pump
  • 3.7 kPa(27.75 mmHg)Negative power
  • 30 WPower of shaking machine
Constant Temperature Needle Penetration Tester LTNP-A10
  • 0 to 700 taper degree (digital display table 0-70 mm)Measuring range
  • Timing error is less than ±0.1 sTiming device
  • 0.01 mm Resolution
  • ±1 cone insertion degreeNeedle insertion accuracy
Rotational Viscometer LRV-A10
  • 10 ~ 2000000 MPa•sViscosity measurement range
  • 5 °C ~ 35 °CAmbient temperature
  • Not more than 80 %Ambient humidity
  • Four spindles of No.1 ~ 4Spindles