Distillate Fuel Oil Oxidation Stability Tester LOST-D12

Labtron LOST-D12 is a standard floor type model designed with digital temperature controller for accurate temperature controlling. Made of stainless steel and its shelf is treated by spray plastic for a better corrosion resistance ability. Equipped with flow meter for adjusting oxygen flow rate.

  • Samples 8
    Temperature 100 ℃
    Oil bath cubage
    Angle between bomb and water surface
    Speed of rotary assembly
    Pressure sensor
    Oil bath Temperature controlling range
    Temperature controlling mode
    Temperature controlling range
    Temperature controlling accuracy 0.1 ℃
    Flow meter 3 ± 0.3 L / H oxygen
    Size
    Power of heater
    Power supply 220 V ± 10 %, 60 Hz
    Power consumption
    Weight
    Dimension
    • Floor standard type
    • Main unit comprises of water bath, flow controller and cooling system
    • Digital temperature controller (for accurate temperature controlling)
    • Made of stainless steel for better corrosion resistance
    • Flow meter for adjusting the oxygen flow rate
  • It can be widely used in petroleum, chemical industries, research and development laboratories. It is suitable for determining oxidation stability of distillate fuels by accelerating methods..

Transformer Oil Oxidation Stability Tester LOST-D11

  • 6Samples
  • Automatic digital temperatureTemperature controlling mode
  • Room temperature ~ 160 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy

Oxidation Stability Tester (Lubricating Grease) LOST-D20

  • Ambient to 150℃Temperature Range
  • ± 0.1°CTemperature Precision
  • 2 unitsTest Unit
  • 1800 WHeating Power

Gasoline Oxidation Stability Tester LOST-D13

  • Compact; DesktopType
  • IntegratedDesign
  • Metal bath (without water usage)Bath
  • 100℃ ± 1℃Temperature control point of metal bath
Automatic Lubricating Oils Oxidation Stability Tester LOST-D10
  • 2Samples
  • 30 LOil bath cubage
  • 30 °Angle between bomb and water surface
  • 100 ± 5 RPMSpeed of rotary assembly

Insulating Oil Breakdown Voltage Tester LIBT-A23

  • AC 220 V ± 5 % , 50HzPower supply
  • 0 ~ 75 kVMeasurement range
  • 3 kV ± 10 % / sVoltage rising rate
  • 2.5 mmDistance between electrodes

Wax Oil Content Tester LWCT-A22

  • AC 220 V ± 10 %, 50 HzPower supply
  • RT ~ 90 ℃ ± 5 ℃Temperature controlling range in water bath
  • (-35) ℃ ± 1 ℃Cooling bath temperature
  • 35 ℃ ± 1 ℃Evaporation temperature
Mechanical Impurity Tester (Weight Method) LMIT-A21
  • 390 x 260 x 590 mmDimension
  • ≤ 1200 WTotal power consumption
  • AC 220 V ± 10 %, 50 HzPower supply
  • 1000 WHeating power of water bath
Oxygen Bomb Calorimeter LBC-C20
  • 14000 ~ 15000 J / KHeat capacity
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb

Oxygen Bomb Calorimeter LBC-C22

  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
  • 15 ~ 28 ℃Operation environment temperature

Oxygen Bomb Calorimeter LBC-C21

  • 10 ℃ ~ 35 ℃Temperature controlling range
  • 0.001 ℃Temperature resolution
  • 15 kJ / KMean value of heat capacity
  • 20 ℃ ± 5 ℃Ambient temperature
Vapor Pressure Tester (REID METHOD) LVPT-C10
  • RT ~ 90 °COperation temperature of water bath
  • ± 0.1 °CTemperature controlling accuracy
  • 550 × 520 × 102 mmDimensions
  • ± 0.4 % kPaPressure meter accuracy
Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11
  • Two samples or a group of parallel samplesTest bomb
  • 37.8 °CBath temperature
  • 0.1 °CTemperature controlling accuracy
  • 500 × 560 × 680 mm, 950 × 540 × 720 mmDimensions

Water Content Tester LWT-A10

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination

Coulometric Karl Fischer Titrator LWT-A30

  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed
Water Content Tester LWT-A11
  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination
Dropping Point Tester (Air bath) LDPT-A11
  • ≤ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 250 W × 2Heating power of electric furnace
  • ≤ 700 WTotal power consumption

Dropping Point Tester (Oil Bath) LDPT-A10

  • 600 mlBeaker quantity
  • (-10) °C ~ 40 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • (-5) °C ~ 300 °CThermometer Measurement range