Transformer Oil Oxidation Stability Tester LOST-D11

Labtron LOST-D11 features metal bath for uniform heating, keeping the temperature constant. Equipped with pressure reducer ensuring constant output pressure of the gas cylinder when the pressure in the gas cylinder decreases. Furnished with 6 flow meters to adjust and indicate the flow rate in 6 oxidation tubes.

  • Samples 6
    Temperature
    Oil bath cubage
    Angle between bomb and water surface
    Speed of rotary assembly
    Pressure sensor
    Oil bath Temperature controlling range
    Temperature controlling mode Automatic digital temperature
    Temperature controlling range Room temperature ~ 160 °C
    Temperature controlling accuracy ± 0.2 °C
    Flow meter
    Size
    Power of heater
    Power supply 220 V, 50 Hz
    Power consumption ≤ 1100 W
    Weight
    Dimension
    • Digital temperature controller for automatic mode
    • Desktop type and compact
    • Pressure reducer (ensuring constant output pressure)
    • Digital timer (presetting and recording test time)
  • It can be widely used in petroleum, chemical industries, research and development laboratories.

Oxidation Stability Tester (Lubricating Grease) LOST-D20

  • Ambient to 150℃Temperature Range
  • ± 0.1°CTemperature Precision
  • 2 unitsTest Unit
  • 1800 WHeating Power

Gasoline Oxidation Stability Tester LOST-D13

  • Compact; DesktopType
  • IntegratedDesign
  • Metal bath (without water usage)Bath
  • 100℃ ± 1℃Temperature control point of metal bath

Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

  • 2Samples
  • 30 LOil bath cubage
  • 30 °Angle between bomb and water surface
  • 100 ± 5 RPMSpeed of rotary assembly
Distillate Fuel Oil Oxidation Stability Tester LOST-D12
  • 8Samples
  • 100 ℃Temperature
  • 0.1 ℃Temperature controlling accuracy
  • 3 ± 0.3 L / H oxygenFlow meter

Automatic Tag Closed Flash Point Tester LACF-A10

  • -50 to 70°CExperimental temperature range
  • 50 mlTest sample volume
  • 10 to 40°CAmbient temperature range
  • ≤ 85%Humidity

Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

  • (-10)℃ ~ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 31.0 ~ 32.0 mmSample cup Inner diameter
  • 1.0 ~ 1.5 mmSample cup Wall thickness
Solidifying Point Tester LLTT-A13
  • ± 0.5 ℃Temperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • Two holes in one trough, and same temperatureCold trough
  • ≤ 30 ℃Ambient temperature
Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15
  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity

Water Soluble Acid and Alkali Tester LAAT-A10

  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature

Acid Number and Acidity Tester LAAT-A11

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption
Acid Number Tester LAAT-A12
  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume
Aniline Point Tester LAPT-A10
  • Room temperature ~ 150°CMeasurement range
  • 0 ~ 1200 r / minStirring speed
  • 25 WHeating power
  • 360 × 250 × 545 mmInterior Dimension

Aniline Point Tester LAPT-A11

  • ≤ 0.5 ℃Temperature controlling accuracy
  • Room temperature ~ 200 ℃Temperature controlling range
  • 5 VPower supply for illumination
  • 2 kWPower of motor

Water Content Tester LWT-A10

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination
Water Content Tester LWT-A11
  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination
Coulometric Karl Fischer Titrator LWT-A30
  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed