Rotational Viscometer LRV-A10

Our LRV-A10 Rotational Viscometer has a wide range of application in the market. It is designed with advanced manufacturing technique

  • Viscosity measurement range 10 ~ 2000000 MPa•s
    Ambient temperature 5 °C ~ 35 °C
    Ambient humidity Not more than 80 %
    Spindles Four spindles of No.1 ~ 4
    Spindle speed 0.3, 0.6, 1.5, 3, 6, 12, 30 and 60 rpm
    Measurement error ± 3 % (F•S)
    Power supply AC 220 V ± 10 %, 50 Hz ± 10 %
    =#REF!
    • Advanced mechanical design and manufacture methods
    • Microprocessor controlling technologies
    • Precisely collects test data
    • Ultra-brighten LCD display
    • RS232 port
  • It is used to determine absolute viscosity of Newton liquids and apparent viscosity of non-Newton liquids, grease, paint, plastic, medicine, dope, adhesive, and washing solvents, etc.

Rotational Viscometer LRV-A10

  • 10 ~ 2000000 MPa•sViscosity measurement range
  • 5 °C ~ 35 °CAmbient temperature
  • Not more than 80 %Ambient humidity
  • Four spindles of No.1 ~ 4Spindles

Automatic Thermogravimetric Analyzer LTGA-A10

  • Room temperature to 1000 ºC Temperature range
  • 0.1 ºCTemperature resolution
  • ±0.1 ºCTemperature fluctuation
  • 1 ~ 80 ºC / minHeating rate
Acid Number Tester LAAT-A12
  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume
Acid Number and Acidity Tester LAAT-A11
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption

Water Soluble Acid and Alkali Tester LAAT-A10

  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature

Automatic Tag Closed Flash Point Tester LACF-A10

  • -50 to 70°CExperimental temperature range
  • 50 mlTest sample volume
  • 10 to 40°CAmbient temperature range
  • ≤ 85%Humidity
Carbon Residue Tester (CONRADSON METHODS) LRCT-B10
  • 30 mlPorcelain crucible
  • 75 mlInner iron crucible
  • 190 mlOuter iron crucible
  • Mig BurnerBurner
Carbon Residue Tester (Ramsbottom) LRCT-B20
  • Metal furnaceCoking furnace
  • Electric heatingHeating mode
  • 5 unitsTest unit
  • Ambient to 550°CTemperature range

Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11

  • Four holes with a furnaceBath type
  • Electric resistance furnaceHeating type
  • 0 ~ 520 °CTemperature controlling range
  • ± 5 °CTemperature controlling accuracy