Automatic Tag Closed Flash Point Tester LACF-A10

Automatic Tag Closed Flash Point Tester LACF-A10 is a highly automated machine with -50°C lowest flash point and simple operations. Used to determine flash point of liquids with viscosity below 5.5 cSt (mm2/s) at 40°C (104°F) or below 9.5 cSt (mm2/s) at 25°C (77°F) and flash point below 93°C (200°F) . Test method is complied with ASTM D56 international standard.

  • Experimental temperature range -50 to 70°C
    Test sample volume 50 ml
    Ambient temperature range 10 to 40°C
    Humidity ≤ 85%
    Ignition gas source Pipelined gas or LPG
    Gas pressure < 10 kPa
    Cooling method 2 Danfoss compressor refrigeration
    Temperature Sensor Glass PT100 sensor
    Display Touch screen LCD display
    Printing method Thermal printer
    Dimension 700 × 700 × 750 mm
    Weight 110 kg
    Power supply AC 200 V ± 10 % 50 Hz
    Power 1500 W
    • Fast cooling speed
    • Equipped with liquid position overflow port, filling port
    • High depth testing at -50°C (lowest flash point) for test sample
    • Adopted with stainless steel, anti-aging gas circuit
    • 50 ml Test sample volume
  • Used in analysis of flash point of materials at low temperature value across petroleum, chemical, oil, paint and other industries.

X-ray Fluorescence Sulfur in Oil Analyzer LST-A10

  • 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)Sample quantity
  • 60, 120, 240, 300, and 600 s at randomMeasurement time
  • 7 ppm to 5 %Measurement range
  • < 0.029 (S + 0.6)Repeatability

Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11

  • Not less than 150 L / hAir flow rate
  • 99 min 59 s (100 min)Max. Preset time
  • Φ22 mmChamber diameter of oven
  • 1400 W × 2Heating power of oven
Density Tester LDMT-A10
  • Ф300 × 380 mmCubage of bath
  • 0 °C ~ 100 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
  • Industrial platinum resistance, Pt100Temperature sensor
Automatic COC Flash & Fire Point Tester LOFP-B10
  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability

Open Cup Flash Point Tester LOFP-A10

  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity

Cleveland Open Cup Flash Point Tester LOFP-A11

  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature
Foaming Characteristics Tester LFCT-A10
  • Ambient to 100°CTemperature Range
  • ± 0.1°CTemperature Precision
  • 94 mL ± 5 mL/min, with flowmetersAir Flow
  • 0 to 99 min 59 s, resolution 1 sTiming Unit
Distillate Fuel Oil Oxidation Stability Tester LOST-D12
  • 8Samples
  • 100 ℃Temperature
  • 0.1 ℃Temperature controlling accuracy
  • 3 ± 0.3 L / H oxygenFlow meter

Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

  • 2Samples
  • 30 LOil bath cubage
  • 30 °Angle between bomb and water surface
  • 100 ± 5 RPMSpeed of rotary assembly

Transformer Oil Oxidation Stability Tester LOST-D11

  • 6Samples
  • Automatic digital temperatureTemperature controlling mode
  • Room temperature ~ 160 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy