Automatic Tag Closed Flash Point Tester LACF-A10

Automatic Tag Closed Flash Point Tester LACF-A10 is a highly automated machine with -50°C lowest flash point and simple operations. Used to determine flash point of liquids with viscosity below 5.5 cSt (mm2/s) at 40°C (104°F) or below 9.5 cSt (mm2/s) at 25°C (77°F) and flash point below 93°C (200°F) . Test method is complied with ASTM D56 international standard.

  • Experimental temperature range -50 to 70°C
    Test sample volume 50 ml
    Ambient temperature range 10 to 40°C
    Humidity ≤ 85%
    Ignition gas source Pipelined gas or LPG
    Gas pressure < 10 kPa
    Cooling method 2 Danfoss compressor refrigeration
    Temperature Sensor Glass PT100 sensor
    Display Touch screen LCD display
    Printing method Thermal printer
    Dimension 700 × 700 × 750 mm
    Weight 110 kg
    Power supply AC 200 V ± 10 % 50 Hz
    Power 1500 W
    • Fast cooling speed
    • Equipped with liquid position overflow port, filling port
    • High depth testing at -50°C (lowest flash point) for test sample
    • Adopted with stainless steel, anti-aging gas circuit
    • 50 ml Test sample volume
  • Used in analysis of flash point of materials at low temperature value across petroleum, chemical, oil, paint and other industries.

X-ray Fluorescence Sulfur in Oil Analyzer LST-A10

  • 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)Sample quantity
  • 60, 120, 240, 300, and 600 s at randomMeasurement time
  • 7 ppm to 5 %Measurement range
  • < 0.029 (S + 0.6)Repeatability

Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11

  • Not less than 150 L / hAir flow rate
  • 99 min 59 s (100 min)Max. Preset time
  • Φ22 mmChamber diameter of oven
  • 1400 W × 2Heating power of oven
Engler Viscometer LEV-B10
  • 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)Graduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • 10 °C ~ 40 °CAmbient Temperature
Engler Viscometer LEV-A10
  • 200 ± 0.2 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.2 °CTemperature Controlling Accuracy

Engler Viscometer LEV-A11

  • 100 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.1 °CTemperature Controlling Accuracy

Automatic Tag Closed Flash Point Tester LACF-A10

  • -50 to 70°CExperimental temperature range
  • 50 mlTest sample volume
  • 10 to 40°CAmbient temperature range
  • ≤ 85%Humidity
Specific Gravity Tester LSGT-A10
  •  4000 ml × 2Vessel Volume
  • 160 WPower of Vacuum pump
  • 3.7 kPa(27.75 mmHg)Negative power
  • 30 WPower of shaking machine
Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11
  • Two samples or a group of parallel samplesTest bomb
  • 37.8 °CBath temperature
  • 0.1 °CTemperature controlling accuracy
  • 500 × 560 × 680 mm, 950 × 540 × 720 mmDimensions

Vapor Pressure Tester (REID METHOD) LVPT-C10

  • RT ~ 90 °COperation temperature of water bath
  • ± 0.1 °CTemperature controlling accuracy
  • 550 × 520 × 102 mmDimensions
  • ± 0.4 % kPaPressure meter accuracy