Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10 comes with automatic oxygen filling and releasing, fully automatic bomb raising and lowering system. Equipped with propeller to achieve high stirring efficiency, and faster oxygen bomb heat transfer to reduce test period. It is in accordance with international standards ASTM D5865, ISO 1928.

  • Calorimeter type Isoperibol
    Oxygen filling Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
    Bomb volume 250 ml
    Analysis time < 8 min full test process: <10 min
    Bomb washing Manual
    Bomb pressure (maximum) 20 MPa
    Bomb identity Yes
    No. of Tests 6/hour
    Temperature resolution 0.0001 K
    Precision (RSD) ≤ 0.01 %
    Heat Capacity Stability ≤ 0.25 % within three months
    Gas requirement 99.5 % oxygen
    Water requirements Distilled water
    Energy measurement range 0 to 50000 J
    Bucket filling Automatic
    Stirring method Propeller
    Reproducibility 0.10 % (analysis of 1 g of benzoic acid)
    Temperature Increase 2°C (average)
    Temperature measurement PT1000 (temperature probe)
    Working temperatures ≤ 32°C
    Cooling type Refrigerating device
    Network Yes
    Maximum Power 0.6 kW
    Power Inverter No
    Power supply 220 V ±, 15 to 10 %, 50/60 Hz
    Advance Calculations Yes
    Dimension Main body: 440 × 550 × 460 mm Water Tank: 390 × 550 × 440 mm
    Weight 50 kg
    • Unique bucket water circle system, automatic determination water volume
    • Easy assembly and disassembly of stainless steel oxygen bomb
    • Built-in intelligent water tank with heating and cooling function
    • Helix tube multipoint isothermal technology
    • Independent jacket and bucket water system
    • Large heat capacity with stable and accurate results
    • Self-protection, self-diagnostic function
    • Analysis, statistics report, system monitor
    • Unique crucible support design, easy to use
  • Used in determination of calorific value of solid and liquid combustibles such as coal, coke, oil, petroleum material, biomass, cement and others.

  • Accessories no. Name Unit Qty.
    1 Ignition thread (500 pieces) Box Box 20
    2 Standard Benzoic Acid (1 gm * 10 pieces) Bottle 10
    3 Gasket Ring for Oxygen Filling Facility (big, middle, small) Set 15
    4 Heating Crucible PC 60
    5 Oxygen bomb gasket ring (big, middle, small) Set 15
    6 Plastic insulation cover Set 5
    7 Special Oxygen filling pipe PC 2
    8 Electrodes Set 1

Automatic Bomb Calorimeter LABC-B11

  • IsoperibolCalorimeter type
  • Semi-automaticOxygen filling
  • 282 mlBomb volume
  • 15 to 25 minAnalysis time

Automatic Bomb Calorimeter LABC-A11

  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant modeOperation Mode

Automatic Bomb Calorimeter LABC-A10

  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • The outer barrel temperature is constantOperation Mode

Specific Gravity Tester LSGT-A10

  •  4000 ml × 2Vessel Volume
  • 160 WPower of Vacuum pump
  • 3.7 kPa(27.75 mmHg)Negative power
  • 30 WPower of shaking machine

Automatic Tag Closed Flash Point Tester LACF-A10

  • -50 to 70°CExperimental temperature range
  • 50 mlTest sample volume
  • 10 to 40°CAmbient temperature range
  • ≤ 85%Humidity
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Room temperature to 99.9 °CTemperature controlling range
  • ± 1 °CTemperature controlling accuracy
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 1 s to 9 min 59 sTiming range
  • Room temperature to 99.9 °CTemperature controlling range

Open Cup Flash Point Tester LOFP-A10

  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity

Cleveland Open Cup Flash Point Tester LOFP-A11

  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature
Automatic COC Flash & Fire Point Tester LOFP-B10
  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability
Engler Viscometer LEV-B10
  • 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)Graduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • 10 °C ~ 40 °CAmbient Temperature

Engler Viscometer LEV-A11

  • 100 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.1 °CTemperature Controlling Accuracy

Engler Viscometer LEV-A10

  • 200 ± 0.2 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.2 °CTemperature Controlling Accuracy