Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11 comes with semi-automatic oxygen filling and releasing system. Equipped with blades to achieve high stirring efficiency, and faster heat transfer of oxygen bomb to reduce test period. It is confirmed to the international standards ASTM D5865, ISO 1928.

  • Calorimeter type Isoperibol
    Oxygen filling Semi-automatic
    Bomb volume 282 ml
    Analysis time 15 to 25 min
    Bomb washing Manual
    Bomb pressure (maximum) 20 MPa
    Bomb identity No
    No. of Tests 2 to 4/ hour
    Temperature resolution 0.0001 K
    Precision (RSD) ≤ 0.15 %
    Heat Capacity Stability ≤ 0.25 % within three months
    Gas requirement 99.5 % Oxygen
    Water requirements Distilled water
    Energy measurement range 0 to 50000 J
    Bucket filling Semi-Automatic
    Stirring method Blade
    Reproducibility 0.15 % (analysis of 1 g of benzoic acid)
    Temperature Increase 2°C (average)
    Temperature measurement PT1000 (temperature probe)
    Working temperatures ≤ 32°C
    Cooling type Automatic by water circulation
    Network Yes
    Maximum Power 0.5 kW
    Power Inverter No
    Power supply 220 V ±, 15 to 10 %, 50/60 Hz
    Advance Calculations No
    Dimension Main body: 600 × 417 × 908 mm
    Weight 106 kg
    • Supports oxygen bomb tightness examination
    • Delivers accurate test results using large quantities water
    • Difference of jacket water temperature in each test is less than 0.1K
    • Strong data processing capability, statistics report, printing function
    • Authentic test data, No software modification
    • RS232 interface
    • Reliable teste data, no need of software modification
  • Used in coal, petroleum, cement, farming, medical research, electronics for measurement of Calorific Value of combustible materials.

  • Accessories no. Name Unit Qty.
    1 Ignition thread (500 pieces) Box Box 20
    2 Standard Benzoic Acid (1 gm * 10 pieces) Bottle 10
    3 Gasket Ring for Oxygen Filling Facility (big, middle, small) Set 15
    4 Heating Crucible PC 60
    5 Oxygen bomb gasket ring (big, middle, small) Set 15
    6 Plastic insulation cover Set 5
    7 Special Oxygen filling pipe PC 2
    8 Electrodes Set 1

Automatic Bomb Calorimeter LABC-B10

  • IsoperibolCalorimeter type
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & loweringOxygen filling
  • 250 mlBomb volume
  • < 8 min full test process: <10 minAnalysis time

Automatic Bomb Calorimeter LABC-A10

  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • The outer barrel temperature is constantOperation Mode

Automatic Bomb Calorimeter LABC-A11

  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant modeOperation Mode

Vapor Pressure Tester (REID METHOD) LVPT-C10

  • RT ~ 90 °COperation temperature of water bath
  • ± 0.1 °CTemperature controlling accuracy
  • 550 × 520 × 102 mmDimensions
  • ± 0.4 % kPaPressure meter accuracy

Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11

  • Two samples or a group of parallel samplesTest bomb
  • 37.8 °CBath temperature
  • 0.1 °CTemperature controlling accuracy
  • 500 × 560 × 680 mm, 950 × 540 × 720 mmDimensions
Automatic PMCC Flash Point Tester LCFP-A13
  • 10 °C ~ 40 ℃Ambient temperature
  • ≤ 80 %Relative humidity
  • electron igniter / gas flameIgnition Mode
  • Room Temperature ~ 300 ℃Temperature range
PMCC Flash Point Tester LCFP-A10
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °CTemperature range
  • 0.8 mmAperture of ignition device

Automatic PMCC Flash Point Tester LCFP-A11

  • 10 °C ~ 40 °CAmbient temperature
  • ≤ 80 %Relative humidity
  • Ambient Temperature ~ 250 °CMeasurement Range
  • Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °CFlash Point

Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

  • 2Samples
  • 30 LOil bath cubage
  • 30 °Angle between bomb and water surface
  • 100 ± 5 RPMSpeed of rotary assembly
Transformer Oil Oxidation Stability Tester LOST-D11
  • 6Samples
  • Automatic digital temperatureTemperature controlling mode
  • Room temperature ~ 160 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
Distillate Fuel Oil Oxidation Stability Tester LOST-D12
  • 8Samples
  • 100 ℃Temperature
  • 0.1 ℃Temperature controlling accuracy
  • 3 ± 0.3 L / H oxygenFlow meter

Constant Temperature Needle Penetration Tester LTNP-A10

  • 0 to 700 taper degree (digital display table 0-70 mm)Measuring range
  • Timing error is less than ±0.1 sTiming device
  • 0.01 mm Resolution
  • ±1 cone insertion degreeNeedle insertion accuracy

Acid Number and Acidity Tester LAAT-A11

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption
Acid Number Tester LAAT-A12
  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume
Water Soluble Acid and Alkali Tester LAAT-A10
  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature