PMCC Flash Point Tester LCFP-A10

LCFP-A10 is compact, stand-alone closed cup flash point tester which determines the low temperature operability in diesel fuel, biodiesel, blends and gas oils. It is designed as per “Test Methods for Flash Point of Petroleum Products (Pensky-Martens Closed Cup Methods)” ASTM D93.

  • Ambient temperature ≤ 35 °C
    Relative humidity ≤ 85 %
    Ignition Mode
    Temperature range 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C
    Aperture of ignition device 0.8 mm
    Standard oil cup-Inner diameter 50.7 ~ 50.8 mm
    Standard oil cup- Depth 55.7 ~ 56.0 mm
    Standard oil cup- Depth of Marked line on the oil cup 33.9 ~ 34.3 mm
    Standard oil cup-Oil sample cubage About 70 ml
    Stirring speed 90 ~ 120 rpm for procedure A; 250 ± 10 rpm for procedure B
    Stirring blade 8 × 40 mm
    Sample temperature rising rate 1 ~ 12 °C per minute
    Measurement Range
    Flash Point
    Resolution
    Repeatability
    Reproducibility
    Accuracy
    Precision
    Gas Flame
    Heating power 0 ~ 600 W
    Dimension 420 × 350 × 350 mm
    Total Power Consumption 600 W
    Power supply AC 220 V ± 10 %, 50 Hz
    Net Weight
    • Ignition source : Coal gas
    • Rod type Mercury Thermometer
    • Variable Temperature Range
    • 45TYZ Stirring Motor
  • It is suitable to determine closed cup flash point of petroleum products having a flash point higher than 40 °C

Automatic PMCC Flash Point Tester LCFP-A13

  • 10 °C ~ 40 ℃Ambient temperature
  • ≤ 80 %Relative humidity
  • electron igniter / gas flameIgnition Mode
  • Room Temperature ~ 300 ℃Temperature range

Automatic PMCC Flash Point Tester LCFP-A11

  • 10 °C ~ 40 °CAmbient temperature
  • ≤ 80 %Relative humidity
  • Ambient Temperature ~ 250 °CMeasurement Range
  • Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °CFlash Point

Vapor Pressure Tester (REID METHOD) LVPT-C10

  • RT ~ 90 °COperation temperature of water bath
  • ± 0.1 °CTemperature controlling accuracy
  • 550 × 520 × 102 mmDimensions
  • ± 0.4 % kPaPressure meter accuracy

Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11

  • Two samples or a group of parallel samplesTest bomb
  • 37.8 °CBath temperature
  • 0.1 °CTemperature controlling accuracy
  • 500 × 560 × 680 mm, 950 × 540 × 720 mmDimensions
Octane Number and Cetane Number Tester LOCT-A10
  • 86.0 to 105.0/MON Measuring Range For Aviation Gasoline
  • National standard: 65.0 to 110.0/RON
    National-V standard: 70 to 115.0/RON
    Blended gasoline: 75.0 to 120.0/RON
    Light gasoline: 50.0 to 85.0 /MON
    Isomerized gasoline: 85.0 to 120.0/RON
    Arene gasoline: 90.0 to 120.0/RON
     Measuring Range For Gasoline For Motor Vehicles
  • E93: 92.0 to 95.0/RON
    E97: 95.0 to 99.0/RON
    Judgement: 60.0 to 120.0/RON
     Measuring Range For Ethanol
  • Cetane number: 25 to 75/CN
    Cetane index: 20 to 80/CI
    Measuring Range For Automobile Diesel Fuels
Portable Octane Number and Cetane Meter LOCT-A20
  • motor gasoline and dieselMeasurement item
  • 40 to 120measurement unit of octane is ON
  • ± 0.5 maxPermissible error of octane
  • ± 0.2 maxFluctuate range of octane

Dropping Point Tester (Air bath) LDPT-A11

  • ≤ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 250 W × 2Heating power of electric furnace
  • ≤ 700 WTotal power consumption

Dropping Point Tester (Oil Bath) LDPT-A10

  • 600 mlBeaker quantity
  • (-10) °C ~ 40 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • (-5) °C ~ 300 °CThermometer Measurement range
Automatic COC Flash & Fire Point Tester LOFP-B10
  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability
Cleveland Open Cup Flash Point Tester LOFP-A11
  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature

Open Cup Flash Point Tester LOFP-A10

  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity

Engler Viscometer LEV-A10

  • 200 ± 0.2 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.2 °CTemperature Controlling Accuracy
Engler Viscometer LEV-B10
  • 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)Graduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • 10 °C ~ 40 °CAmbient Temperature
Engler Viscometer LEV-A11
  • 100 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.1 °CTemperature Controlling Accuracy