Specific Gravity Tester LSGT-A10

Specific Gravity Tester LSGT-A10 determines the theoretical maximum specific gravity of bituminous mixtures in accordance to ASTM D2041 Standard Test Method for Theoretical Maximum Specific Gravity of Bituminous Mixtures (Vacuum process). Adopted with single chip machine technology to shake a loose asphalt mixture sample submerged in water. Vacuum is applied into the sample, to extract out the air bubble.

  • Vessel Volume  4000 ml × 2
    Power of Vacuum pump 160 W
    Negative power 3.7 kPa(27.75 mmHg)
    Power of shaking machine 30 W
    Power supply AC(220±10%)V, 50Hz
    Dimension 510×520×380 mm
    • High test efficiency
    • Test 2 samples at one time
    • Adopts single chip machine technology
    • Equipped with a high-accuracy absolute pressure sensor
    • Vacuum meter showing working status of vacuum pump
    • Water buffer device preventing water flow from negative pressure container into the vacuum pump
  • Suitable for measuring theoretical specific gravity of bituminous mixtures. Can also be used for the calculation of the percent of air voids in compacted bituminous mixtures and the amount of bitumen absorbed by the aggregates.

  • No. Name Unit  Qty
    1 Specific Gravity Tester LSGT-A10 Set 1
    2 Negative pressure container(4000ml) Piece  2
    3 Sealing ring Piece 2
    4 Fuse 3A(Ф5×20) Piece 2
    5 Glass cover-plate Piece 1
    6 Quick-plug and connecting pipe(1 meter) Piece 1
    7 Operation manual Piece 1
  • No. Name
    1 Constant temperature water bath

Acid Number Tester LAAT-A12

  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume

Water Soluble Acid and Alkali Tester LAAT-A10

  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature
Acid Number and Acidity Tester LAAT-A11
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption
Water Content Tester LWT-A11
  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination

Coulometric Karl Fischer Titrator LWT-A30

  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed

Water Content Tester LWT-A10

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Room temperature to 99.9 °CTemperature controlling range
  • ± 1 °CTemperature controlling accuracy
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 1 s to 9 min 59 sTiming range
  • Room temperature to 99.9 °CTemperature controlling range

Automatic Tag Closed Flash Point Tester LACF-A10

  • -50 to 70°CExperimental temperature range
  • 50 mlTest sample volume
  • 10 to 40°CAmbient temperature range
  • ≤ 85%Humidity

Automatic Softening Point Tester LSPT-A10

  • 32 ℃ to 160 ℃Measurement range
  • 35 °CAmbient temperature
  • 0.01 ℃Temperature resolution
  • 1000 mLBeaker volume