Specific Gravity Tester LSGT-A10

Specific Gravity Tester LSGT-A10 determines the theoretical maximum specific gravity of bituminous mixtures in accordance to ASTM D2041 Standard Test Method for Theoretical Maximum Specific Gravity of Bituminous Mixtures (Vacuum process). Adopted with single chip machine technology to shake a loose asphalt mixture sample submerged in water. Vacuum is applied into the sample, to extract out the air bubble.

  • Vessel Volume  4000 ml × 2
    Power of Vacuum pump 160 W
    Negative power 3.7 kPa(27.75 mmHg)
    Power of shaking machine 30 W
    Power supply AC(220±10%)V, 50Hz
    Dimension 510×520×380 mm
    • High test efficiency
    • Test 2 samples at one time
    • Adopts single chip machine technology
    • Equipped with a high-accuracy absolute pressure sensor
    • Vacuum meter showing working status of vacuum pump
    • Water buffer device preventing water flow from negative pressure container into the vacuum pump
  • Suitable for measuring theoretical specific gravity of bituminous mixtures. Can also be used for the calculation of the percent of air voids in compacted bituminous mixtures and the amount of bitumen absorbed by the aggregates.

  • No. Name Unit  Qty
    1 Specific Gravity Tester LSGT-A10 Set 1
    2 Negative pressure container(4000ml) Piece  2
    3 Sealing ring Piece 2
    4 Fuse 3A(Ф5×20) Piece 2
    5 Glass cover-plate Piece 1
    6 Quick-plug and connecting pipe(1 meter) Piece 1
    7 Operation manual Piece 1
  • No. Name
    1 Constant temperature water bath

Foaming Characteristics Tester LFCT-A10

  • Ambient to 100°CTemperature Range
  • ± 0.1°CTemperature Precision
  • 94 mL ± 5 mL/min, with flowmetersAir Flow
  • 0 to 99 min 59 s, resolution 1 sTiming Unit

Oxygen Bomb Calorimeter LBC-C21

  • 10 ℃ ~ 35 ℃Temperature controlling range
  • 0.001 ℃Temperature resolution
  • 15 kJ / KMean value of heat capacity
  • 20 ℃ ± 5 ℃Ambient temperature
Oxygen Bomb Calorimeter LBC-C22
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
  • 15 ~ 28 ℃Operation environment temperature
Oxygen Bomb Calorimeter LBC-C20
  • 14000 ~ 15000 J / KHeat capacity
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb

Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10

  • 2 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 10 to 35°CAmbient temperature
  • Room Temperature to 100°CTemperature controlling range

Copper Strip Corrosion Tester LRCT-A13

  • 4 piecesSample hole
  • 4 to 12 piecesSample quantity
  • Room temperature to 35 °CAmbient temperature
  • Room temperature to 100°CTemperature controlling range
Lubricating Oil Rust Characteristics Tester LRCT-A11
  • 4 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 1000 ± 50 rpmSpeed for sample stirring
  • Room temperature to 35°CAmbient temperature
Rotational Viscometer LRV-A10
  • 10 ~ 2000000 MPa•sViscosity measurement range
  • 5 °C ~ 35 °CAmbient temperature
  • Not more than 80 %Ambient humidity
  • Four spindles of No.1 ~ 4Spindles

Density Tester LDMT-A10

  • Ф300 × 380 mmCubage of bath
  • 0 °C ~ 100 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
  • Industrial platinum resistance, Pt100Temperature sensor