Automatic Thermogravimetric Analyzer LTGA-A10

Automatic Thermogravimetric Analyzer LTGA-A10 is a high performance, efficient unit designed to study thermal stability of materials and its allied components. It offers a resolution of 0.1 ºC and works between temperature range of room temperature to 1000 ºC. Operates in an inert, oxidizing, reducible, static and dynamic atmosphere and possess two-way gas and control flow volume.

  •  Temperature range Room temperature to 1000 ºC
    Temperature resolution 0.1 ºC
    Temperature fluctuation ±0.1 ºC
    Heating rate 1 ~ 80 ºC / min
    Cooling time 15min  (1000ºC ~ 100ºC)
     Balance measuring range 1mg~2g  (Can be extended to 30g)
     Resolution 0.1 u g
    Constant temperature and time 0 ~ 300min (set arbitrarily)
    Atmosphere Inert, oxidizing, reducible, static and dynamic
    Power AC220V, 50Hz
    • LCD display
    • Two-way gas and control flow volume
    • Built-in gas flow meter
    • Temperature control mode: Rising temperature, Cooling temperature, Constant temperature
    • Software to record TG curves automatically
    • Data processing and print data results
    • RS232 interface
  • Thermogravimetric Analyzer gives automatic analysis of Thermal stability, Moisture, Volatiles, Ash, Fixed Carbon Special application for Coal & Coke.

Aniline Point Tester LAPT-A10

  • Room temperature ~ 150°CMeasurement range
  • 0 ~ 1200 r / minStirring speed
  • 25 WHeating power
  • 360 × 250 × 545 mmInterior Dimension

Aniline Point Tester LAPT-A11

  • ≤ 0.5 ℃Temperature controlling accuracy
  • Room temperature ~ 200 ℃Temperature controlling range
  • 5 VPower supply for illumination
  • 2 kWPower of motor
Foaming Characteristics Tester LFCT-A10
  • Ambient to 100°CTemperature Range
  • ± 0.1°CTemperature Precision
  • 94 mL ± 5 mL/min, with flowmetersAir Flow
  • 0 to 99 min 59 s, resolution 1 sTiming Unit
Automatic PMCC Flash Point Tester LCFP-A13
  • 10 °C ~ 40 ℃Ambient temperature
  • ≤ 80 %Relative humidity
  • electron igniter / gas flameIgnition Mode
  • Room Temperature ~ 300 ℃Temperature range

PMCC Flash Point Tester LCFP-A10

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °CTemperature range
  • 0.8 mmAperture of ignition device

Automatic PMCC Flash Point Tester LCFP-A11

  • 10 °C ~ 40 °CAmbient temperature
  • ≤ 80 %Relative humidity
  • Ambient Temperature ~ 250 °CMeasurement Range
  • Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °CFlash Point
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 1 s to 9 min 59 sTiming range
  • Room temperature to 99.9 °CTemperature controlling range
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Room temperature to 99.9 °CTemperature controlling range
  • ± 1 °CTemperature controlling accuracy

Rotational Viscometer LRV-A10

  • 10 ~ 2000000 MPa•sViscosity measurement range
  • 5 °C ~ 35 °CAmbient temperature
  • Not more than 80 %Ambient humidity
  • Four spindles of No.1 ~ 4Spindles