Automatic Thermogravimetric Analyzer LTGA-A10

Automatic Thermogravimetric Analyzer LTGA-A10 is a high performance, efficient unit designed to study thermal stability of materials and its allied components. It offers a resolution of 0.1 ºC and works between temperature range of room temperature to 1000 ºC. Operates in an inert, oxidizing, reducible, static and dynamic atmosphere and possess two-way gas and control flow volume.

  •  Temperature range Room temperature to 1000 ºC
    Temperature resolution 0.1 ºC
    Temperature fluctuation ±0.1 ºC
    Heating rate 1 ~ 80 ºC / min
    Cooling time 15min  (1000ºC ~ 100ºC)
     Balance measuring range 1mg~2g  (Can be extended to 30g)
     Resolution 0.1 u g
    Constant temperature and time 0 ~ 300min (set arbitrarily)
    Atmosphere Inert, oxidizing, reducible, static and dynamic
    Power AC220V, 50Hz
    • LCD display
    • Two-way gas and control flow volume
    • Built-in gas flow meter
    • Temperature control mode: Rising temperature, Cooling temperature, Constant temperature
    • Software to record TG curves automatically
    • Data processing and print data results
    • RS232 interface
  • Thermogravimetric Analyzer gives automatic analysis of Thermal stability, Moisture, Volatiles, Ash, Fixed Carbon Special application for Coal & Coke.

Acid Number Tester LAAT-A12

  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume

Acid Number and Acidity Tester LAAT-A11

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption
Water Soluble Acid and Alkali Tester LAAT-A10
  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature
Oxygen Bomb Calorimeter LBC-C22
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
  • 15 ~ 28 ℃Operation environment temperature

Oxygen Bomb Calorimeter LBC-C21

  • 10 ℃ ~ 35 ℃Temperature controlling range
  • 0.001 ℃Temperature resolution
  • 15 kJ / KMean value of heat capacity
  • 20 ℃ ± 5 ℃Ambient temperature

Oxygen Bomb Calorimeter LBC-C20

  • 14000 ~ 15000 J / KHeat capacity
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
Mechanical Impurity Tester (Weight Method) LMIT-A21
  • 390 x 260 x 590 mmDimension
  • ≤ 1200 WTotal power consumption
  • AC 220 V ± 10 %, 50 HzPower supply
  • 1000 WHeating power of water bath
Wax Oil Content Tester LWCT-A22
  • AC 220 V ± 10 %, 50 HzPower supply
  • RT ~ 90 ℃ ± 5 ℃Temperature controlling range in water bath
  • (-35) ℃ ± 1 ℃Cooling bath temperature
  • 35 ℃ ± 1 ℃Evaporation temperature

Insulating Oil Breakdown Voltage Tester LIBT-A23

  • AC 220 V ± 5 % , 50HzPower supply
  • 0 ~ 75 kVMeasurement range
  • 3 kV ± 10 % / sVoltage rising rate
  • 2.5 mmDistance between electrodes

Kinematics Viscometer LKV-A13

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A11
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A12
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

PMCC Flash Point Tester LCFP-A10

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °CTemperature range
  • 0.8 mmAperture of ignition device

Automatic PMCC Flash Point Tester LCFP-A13

  • 10 °C ~ 40 ℃Ambient temperature
  • ≤ 80 %Relative humidity
  • electron igniter / gas flameIgnition Mode
  • Room Temperature ~ 300 ℃Temperature range
Automatic PMCC Flash Point Tester LCFP-A11
  • 10 °C ~ 40 °CAmbient temperature
  • ≤ 80 %Relative humidity
  • Ambient Temperature ~ 250 °CMeasurement Range
  • Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °CFlash Point