Oxidation Stability Tester (Lubricating Grease) LOST-D20

Oxidation Stability Tester (Lubricating Grease) LOST-D20 is a benchtop unit and offers temperature range of 150°C with precision of ± 0.1°C. Easy to use, safe, reliable and is a small size tester, occupies less space. It is applicable for determination of oxidation stability of grease by oxygen bomb method.

  • Temperature Range Ambient to 150℃
    Temperature Precision ± 0.1°C
    Test Unit 2 units
    Heating Power 1800 W
    Ambient Temperature (Room temperature to 35°C
    Relative Humidity ≤ 85 %
    Power Supply AC (220 ± 10 %) V, 50 Hz
    • Easy to maintain and operate
    • Double test unit and integrated design
    • Equipped with stability and high temperature control precision
    • Convenient for parallel experiments
    • Integrated, automatic timing with alarm prompt system
    • Built-in PID temperature control technology
  • Oxidation Stability Tester is primarily used in quality control, petroleum, chemical research, university and power. It is also used in testing of lubricant oil, fuel oil and crude oil.

  • Sr. No. Name of the Accessory Quantity
    1. Main Unit 1 Set
    2. Temperature Controller 1 Set
    3. Test Bomb 2 Pieces
    4. Digital Pressure Gauge 2 Pieces
    5. Oxygen Tube 1 Piece
    6. Oxygen Decompression Meter 1 Piece
    7. Test Vessel 10 Pieces
    8. Rack of the Test Vessel 2 Pieces
    9. Test Bomb Disassembling Rod 1 Piece
    10. Thermometer 1 Piece
    11. 2 Pieces

Transformer Oil Oxidation Stability Tester LOST-D11

  • 6Samples
  • Automatic digital temperatureTemperature controlling mode
  • Room temperature ~ 160 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy

Gasoline Oxidation Stability Tester LOST-D13

  • Compact; DesktopType
  • IntegratedDesign
  • Metal bath (without water usage)Bath
  • 100℃ ± 1℃Temperature control point of metal bath

Distillate Fuel Oil Oxidation Stability Tester LOST-D12

  • 8Samples
  • 100 ℃Temperature
  • 0.1 ℃Temperature controlling accuracy
  • 3 ± 0.3 L / H oxygenFlow meter
Automatic Lubricating Oils Oxidation Stability Tester LOST-D10
  • 2Samples
  • 30 LOil bath cubage
  • 30 °Angle between bomb and water surface
  • 100 ± 5 RPMSpeed of rotary assembly

Rotational Viscometer LRV-A10

  • 10 ~ 2000000 MPa•sViscosity measurement range
  • 5 °C ~ 35 °CAmbient temperature
  • Not more than 80 %Ambient humidity
  • Four spindles of No.1 ~ 4Spindles

Solidifying Point Tester LLTT-A13

  • ± 0.5 ℃Temperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • Two holes in one trough, and same temperatureCold trough
  • ≤ 30 ℃Ambient temperature
Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12
  • (-10)℃ ~ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 31.0 ~ 32.0 mmSample cup Inner diameter
  • 1.0 ~ 1.5 mmSample cup Wall thickness
Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15
  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity

Automatic Bomb Calorimeter LABC-B10

  • IsoperibolCalorimeter type
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & loweringOxygen filling
  • 250 mlBomb volume
  • < 8 min full test process: <10 minAnalysis time

Automatic Bomb Calorimeter LABC-A11

  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant modeOperation Mode
Automatic Bomb Calorimeter LABC-A10
  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • The outer barrel temperature is constantOperation Mode
Distillate Fuel Oil Oxidation Stability Tester LOST-D12
  • 8Samples
  • 100 ℃Temperature
  • 0.1 ℃Temperature controlling accuracy
  • 3 ± 0.3 L / H oxygenFlow meter

Transformer Oil Oxidation Stability Tester LOST-D11

  • 6Samples
  • Automatic digital temperatureTemperature controlling mode
  • Room temperature ~ 160 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy

Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

  • 2Samples
  • 30 LOil bath cubage
  • 30 °Angle between bomb and water surface
  • 100 ± 5 RPMSpeed of rotary assembly
Automatic Dielectric Tester LADT-A10
  • 2.0 kVACapacity
  • 2 k V/ sSpeed of voltage increase
  • 0.01Voltage inspection accuracy
  • < 0.1 kVBreakdown sensitivity