Oxidation Stability Tester (Lubricating Grease) LOST-D20

Oxidation Stability Tester (Lubricating Grease) LOST-D20 is a benchtop unit and offers temperature range of 150°C with precision of ± 0.1°C. Easy to use, safe, reliable and is a small size tester, occupies less space. It is applicable for determination of oxidation stability of grease by oxygen bomb method.

  • Temperature Range Ambient to 150℃
    Temperature Precision ± 0.1°C
    Test Unit 2 units
    Heating Power 1800 W
    Ambient Temperature (Room temperature to 35°C
    Relative Humidity ≤ 85 %
    Power Supply AC (220 ± 10 %) V, 50 Hz
    • Easy to maintain and operate
    • Double test unit and integrated design
    • Equipped with stability and high temperature control precision
    • Convenient for parallel experiments
    • Integrated, automatic timing with alarm prompt system
    • Built-in PID temperature control technology
  • Oxidation Stability Tester is primarily used in quality control, petroleum, chemical research, university and power. It is also used in testing of lubricant oil, fuel oil and crude oil.

  • Sr. No. Name of the Accessory Quantity
    1. Main Unit 1 Set
    2. Temperature Controller 1 Set
    3. Test Bomb 2 Pieces
    4. Digital Pressure Gauge 2 Pieces
    5. Oxygen Tube 1 Piece
    6. Oxygen Decompression Meter 1 Piece
    7. Test Vessel 10 Pieces
    8. Rack of the Test Vessel 2 Pieces
    9. Test Bomb Disassembling Rod 1 Piece
    10. Thermometer 1 Piece
    11. 2 Pieces

Distillate Fuel Oil Oxidation Stability Tester LOST-D12

  • 8Samples
  • 100 ℃Temperature
  • 0.1 ℃Temperature controlling accuracy
  • 3 ± 0.3 L / H oxygenFlow meter

Gasoline Oxidation Stability Tester LOST-D13

  • Compact; DesktopType
  • IntegratedDesign
  • Metal bath (without water usage)Bath
  • 100℃ ± 1℃Temperature control point of metal bath

Transformer Oil Oxidation Stability Tester LOST-D11

  • 6Samples
  • Automatic digital temperatureTemperature controlling mode
  • Room temperature ~ 160 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
Automatic Lubricating Oils Oxidation Stability Tester LOST-D10
  • 2Samples
  • 30 LOil bath cubage
  • 30 °Angle between bomb and water surface
  • 100 ± 5 RPMSpeed of rotary assembly

Automatic PMCC Flash Point Tester LCFP-A13

  • 10 °C ~ 40 ℃Ambient temperature
  • ≤ 80 %Relative humidity
  • electron igniter / gas flameIgnition Mode
  • Room Temperature ~ 300 ℃Temperature range

PMCC Flash Point Tester LCFP-A10

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °CTemperature range
  • 0.8 mmAperture of ignition device
Automatic PMCC Flash Point Tester LCFP-A11
  • 10 °C ~ 40 °CAmbient temperature
  • ≤ 80 %Relative humidity
  • Ambient Temperature ~ 250 °CMeasurement Range
  • Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °CFlash Point
Specific Gravity Tester LSGT-A10
  •  4000 ml × 2Vessel Volume
  • 160 WPower of Vacuum pump
  • 3.7 kPa(27.75 mmHg)Negative power
  • 30 WPower of shaking machine

Automatic Bomb Calorimeter LABC-A11

  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant modeOperation Mode

Automatic Bomb Calorimeter LABC-B10

  • IsoperibolCalorimeter type
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & loweringOxygen filling
  • 250 mlBomb volume
  • < 8 min full test process: <10 minAnalysis time
Automatic Bomb Calorimeter LABC-A10
  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • The outer barrel temperature is constantOperation Mode
Aniline Point Tester LAPT-A11
  • ≤ 0.5 ℃Temperature controlling accuracy
  • Room temperature ~ 200 ℃Temperature controlling range
  • 5 VPower supply for illumination
  • 2 kWPower of motor

Aniline Point Tester LAPT-A10

  • Room temperature ~ 150°CMeasurement range
  • 0 ~ 1200 r / minStirring speed
  • 25 WHeating power
  • 360 × 250 × 545 mmInterior Dimension

Automatic Dielectric Tester LADT-A10

  • 2.0 kVACapacity
  • 2 k V/ sSpeed of voltage increase
  • 0.01Voltage inspection accuracy
  • < 0.1 kVBreakdown sensitivity