Automatic Cleveland Open Cup Flash Point Tester LOFP-A12

Our LOFP-A12 Flash point tester is equipped with English man-machine interface. It can preset expected flash point temperature and other parameters which is reasonably designed, safe and convenient to operate. It is designed and made as per ISO 2592, ASTM 92 “Test Methods for Flash Point and Fire Point of Petroleum Products (Cleveland Open Cup Methods).

  • Thermometer
    Scale Division
    Spout Aperture
    Ambient Temperature 10 ℃ ~ 40 °C
    Relative Humidity ≤ 80 %
    Temperature Measurement- Full Scale Ambient temperature to 300 °C
    Temperature Measurement- Repeatability ≤ 8 °C
    Temperature Measurement- Reproducibility ≤ 16 °C
    Temperature Measurement- Resolution 0.1 °C
    Test accuracy 0.002
    Reappearance
    Graduation
    Outer Crucible-Material
    Outer Crucible-Diameter Of Upper Opening
    Outer Crucible-Height
    Outer Crucible-Diameter Of Bottom
    Inner Crucible-Material
    Inner Crucible-Diameter Of Upper Opening
    Inner Crucible-Height
    Inner Crucible-Diameter Of Bottom
    Inner Crucible-Scale Line
    Precision 0.005
    Gas Tube
    Flame 3 to 4 mm
    Heater
    Heating Power
    Dimensions 550 x 470 x 410 mm
    Power Consumption ≤ 500 W
    Power Supply AC 220 V ± 10 %, 50 Hz
    =#REF!
    • Automatic program temperature controlling
    • Automatic meteorological pressure standardization and altered value correction
    • Electric flame ignition mode
    • LCD display
    • It can print out test data automatically
    • Convenient and rapid
  • Used to determine flash point of petroleum products and bituminous materials, excepting fuel oil and materials having a flash point of lower than 79 °C

Cleveland Open Cup Flash Point Tester LOFP-A11

  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature

Open Cup Flash Point Tester LOFP-A10

  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity

Automatic COC Flash & Fire Point Tester LOFP-B10

  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability

Water Content Tester LWT-A11

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination

Water Content Tester LWT-A10

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination
Coulometric Karl Fischer Titrator LWT-A30
  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed
Dropping Point Tester (Oil Bath) LDPT-A10
  • 600 mlBeaker quantity
  • (-10) °C ~ 40 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • (-5) °C ~ 300 °CThermometer Measurement range

Dropping Point Tester (Air bath) LDPT-A11

  • ≤ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 250 W × 2Heating power of electric furnace
  • ≤ 700 WTotal power consumption

Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11

  • Not less than 150 L / hAir flow rate
  • 99 min 59 s (100 min)Max. Preset time
  • Φ22 mmChamber diameter of oven
  • 1400 W × 2Heating power of oven
X-ray Fluorescence Sulfur in Oil Analyzer LST-A10
  • 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)Sample quantity
  • 60, 120, 240, 300, and 600 s at randomMeasurement time
  • 7 ppm to 5 %Measurement range
  • < 0.029 (S + 0.6)Repeatability
Density Tester LDMT-A10
  • Ф300 × 380 mmCubage of bath
  • 0 °C ~ 100 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
  • Industrial platinum resistance, Pt100Temperature sensor

Octane Number and Cetane Number Tester LOCT-A10

  • 86.0 to 105.0/MON Measuring Range For Aviation Gasoline
  • National standard: 65.0 to 110.0/RON
    National-V standard: 70 to 115.0/RON
    Blended gasoline: 75.0 to 120.0/RON
    Light gasoline: 50.0 to 85.0 /MON
    Isomerized gasoline: 85.0 to 120.0/RON
    Arene gasoline: 90.0 to 120.0/RON
     Measuring Range For Gasoline For Motor Vehicles
  • E93: 92.0 to 95.0/RON
    E97: 95.0 to 99.0/RON
    Judgement: 60.0 to 120.0/RON
     Measuring Range For Ethanol
  • Cetane number: 25 to 75/CN
    Cetane index: 20 to 80/CI
    Measuring Range For Automobile Diesel Fuels

Portable Octane Number and Cetane Meter LOCT-A20

  • motor gasoline and dieselMeasurement item
  • 40 to 120measurement unit of octane is ON
  • ± 0.5 maxPermissible error of octane
  • ± 0.2 maxFluctuate range of octane