Automatic Cleveland Open Cup Flash Point Tester LOFP-A12

Our LOFP-A12 Flash point tester is equipped with English man-machine interface. It can preset expected flash point temperature and other parameters which is reasonably designed, safe and convenient to operate. It is designed and made as per ISO 2592, ASTM 92 “Test Methods for Flash Point and Fire Point of Petroleum Products (Cleveland Open Cup Methods).

  • Thermometer
    Scale Division
    Spout Aperture
    Ambient Temperature 10 ℃ ~ 40 °C
    Relative Humidity ≤ 80 %
    Temperature Measurement- Full Scale Ambient temperature to 300 °C
    Temperature Measurement- Repeatability ≤ 8 °C
    Temperature Measurement- Reproducibility ≤ 16 °C
    Temperature Measurement- Resolution 0.1 °C
    Test accuracy 0.002
    Reappearance
    Graduation
    Outer Crucible-Material
    Outer Crucible-Diameter Of Upper Opening
    Outer Crucible-Height
    Outer Crucible-Diameter Of Bottom
    Inner Crucible-Material
    Inner Crucible-Diameter Of Upper Opening
    Inner Crucible-Height
    Inner Crucible-Diameter Of Bottom
    Inner Crucible-Scale Line
    Precision 0.005
    Gas Tube
    Flame 3 to 4 mm
    Heater
    Heating Power
    Dimensions 550 x 470 x 410 mm
    Power Consumption ≤ 500 W
    Power Supply AC 220 V ± 10 %, 50 Hz
    =#REF!
    • Automatic program temperature controlling
    • Automatic meteorological pressure standardization and altered value correction
    • Electric flame ignition mode
    • LCD display
    • It can print out test data automatically
    • Convenient and rapid
  • Used to determine flash point of petroleum products and bituminous materials, excepting fuel oil and materials having a flash point of lower than 79 °C

Open Cup Flash Point Tester LOFP-A10

  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity

Automatic COC Flash & Fire Point Tester LOFP-B10

  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability

Cleveland Open Cup Flash Point Tester LOFP-A11

  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature

Automatic Bomb Calorimeter LABC-B10

  • IsoperibolCalorimeter type
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & loweringOxygen filling
  • 250 mlBomb volume
  • < 8 min full test process: <10 minAnalysis time

Automatic Bomb Calorimeter LABC-A10

  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • The outer barrel temperature is constantOperation Mode
Automatic Bomb Calorimeter LABC-A11
  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant modeOperation Mode
X-ray Fluorescence Sulfur in Oil Analyzer LST-A10
  • 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)Sample quantity
  • 60, 120, 240, 300, and 600 s at randomMeasurement time
  • 7 ppm to 5 %Measurement range
  • < 0.029 (S + 0.6)Repeatability

Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11

  • Not less than 150 L / hAir flow rate
  • 99 min 59 s (100 min)Max. Preset time
  • Φ22 mmChamber diameter of oven
  • 1400 W × 2Heating power of oven

Mercaptan Sulfur Tester LMST-A10

  • (0 to ±1999.5) MvPotential measuring range
  • 0.1 % ±0.5 mVIntrinsic error
  • Ri ≥1 × 1012 ΩInput impedance
  • 10 mLBurette capacity
Water Content Tester LWT-A11
  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination
Water Content Tester LWT-A10
  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination

Coulometric Karl Fischer Titrator LWT-A30

  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed

Kinematics Viscometer LKV-A13

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A12
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A11
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor