X-ray Fluorescence Sulfur in Oil Analyzer LST-A10

Labtron LST-A10 is incorporated with self-diagnostic function and electromagnetic integration. It is designed according to International Standards ASTM D4294 and ASTM D7039 for repeatability and reproducibility.

  • Air flow rate
    Max. Preset time
    Chamber diameter of oven
    Heating power of oven
    Max. Temperature of oven
    Sample quantity 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)
    Measurement time 60, 120, 240, 300, and 600 s at random
    Measurement range 7 ppm to 5 %
    Repeatability < 0.029 (S + 0.6)
    Reproducibility < 0.063 (S + 0.6)
    Temperature 5 ℃ to 40 ℃
    Relative humidity ≤ 85 % (30 ℃)
    Power supply AC 220 V ± 20 V, 50 Hz
    Rated power 30 W
    Dimensions 468 x 368 x 136 mm
    Weight 13 kg
    • Microprocessor controller
    • Large screen LCD display
    • Rapid and convenient
    • Save large quantity of test data
  • It is used to determine mass % of total sulfur in the crude petroleum, petroleum, heavy oil, diesel oil, gasoline and naphtha. It can be used to determine total sulfur content in the products of coal chemical industry, such as primary benzene and other liquid or solid powder samples.

Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11

  • Not less than 150 L / hAir flow rate
  • 99 min 59 s (100 min)Max. Preset time
  • Φ22 mmChamber diameter of oven
  • 1400 W × 2Heating power of oven

Automatic Dielectric Tester LADT-A10

  • 2.0 kVACapacity
  • 2 k V/ sSpeed of voltage increase
  • 0.01Voltage inspection accuracy
  • < 0.1 kVBreakdown sensitivity

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10

  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 1 s to 9 min 59 sTiming range
  • Room temperature to 99.9 °CTemperature controlling range
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Room temperature to 99.9 °CTemperature controlling range
  • ± 1 °CTemperature controlling accuracy
Ash Content Tester LACT-A10
  • {"Controlled\u00a0temperature":"775 \u00b125 \u2103","Temperature rising time of empty chamber":"\u2264 50 min","Furnace temperature uniformity":"\u2264 15\u2103","Internal dimension":"200 \u00d7 120 \u00d7 80 mm","External dimension":"490 \u00d7 490 \u00d7 450 mm","Power consumption":"2.5 kW","Power supply":"AC 220V \u00b110%, 50 Hz","Net weight":"35 kg"}Electric Muffle Furnace
  • {"Maximum control temperature":"1200 \u2103","Dimension":"500 \u00d7 300 \u00d7 235 mm","Power consumption":"5000 W","Power supply":"AC 220\u00b110% V, 50Hz","Net weight":"5 kg"}Temperature controller
  • {"Heating power":"(1 to 6) grades, continuously adjustable","Temperature":"400\u2103","Diameter of heating plate":"\u03a6 180 mm","Dimension":"280 \u00d7 250 \u00d7 90 mm","Power consumption":"2000 W","Power supply":"AC 220\u00b110%V, 50Hz"}Electric heating plate

Water Soluble Acid and Alkali Tester LAAT-A10

  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature

Acid Number and Acidity Tester LAAT-A11

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption
Acid Number Tester LAAT-A12
  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume
Dropping Point Tester (Oil Bath) LDPT-A10
  • 600 mlBeaker quantity
  • (-10) °C ~ 40 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • (-5) °C ~ 300 °CThermometer Measurement range

Dropping Point Tester (Air bath) LDPT-A11

  • ≤ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 250 W × 2Heating power of electric furnace
  • ≤ 700 WTotal power consumption