Kinematics Viscometer LKV-A12

Labtron LKV-A12 is designed and made as per ASTMD445 “Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids”. Its temperature accuracy can reach up to ±0.01°C.

  • Ambient temperature (-10) °C ~ 35 °C
    Relative humidity ≤ 85 %
    Capillary viscometer 11 pieces
    Stirring motor 6 W, 1200 rpm
    Sample quantity
    Bath temperature
    Measurement range
    Bath cubage
    Temperature controlling range Ambient temperature ~ 100 °C
    Temperature controlling accuracy ± 0.1 °C
    Illumination
    Constant temperature bath 20 L, two layer bath
    Timing range
    Barometric
    Timing accuracy
    Timing device 0.1 s ~ 999.9 s, resolution is 0.1 s
    Temperature sensor
    Inner capillary viscometer diameters 0.4, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0, 2.5, 3.0, 3.5 and 4.0 mm respectively
    Mercury thermometer scale division
    • Heat preservation cover (double shell)
    • Digital display
    • Hard glass bath
    • Convenient to use desktop design
    • Temperature control accuracy can reach ± 0.01℃
    • Electric stirrer to ensure the uniformity of bath temperature
  • It is used in the fields of petroleum & its products industries, research and development department.

Kinematics Viscometer LKV-A16

  • 0 ~ 40 ºCAmbient temperature
  • 20 ~ 90 %, RH while 40 ℃Relative humidity
  • ± 0.1 °CTemperature controlling accuracy
  • 0.0 s ~ 9999.9 sTiming range

Kinematics Viscometer LKV-A10

  • 15 to 35°CAmbient temperature
  • ≤ 85%Relative humidity
  • 6 capillary Pinkevitch viscometer tubesCapillary viscometer
  • 1200 rpmStirring motor

Kinematics Viscometer LKV-A11

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A15
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A13
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Low Temperature Kinematic Viscosity Tester LKV-A14

  • ≤ 30 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 13 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Benzene Distillation Tester (Low Temperature) LDT-A11

  • -10°C to 35°CAmbient temperature
  • ≤ 85 %Relative humidity
  • Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°CThermometer
  • 0.1 ℃Scale division

Automatic Distillation Apparatus LADA-A10

  • 2 kWHeating power
  • 0.5 kWCooling power
  • 0 to 400℃Steam temperature
  • 0 to 500℃Oven temperature
Distillation Tester Dual Units LDT-A15
  • 100 mlGraduated flasks
  • 1mlScale division of graduated flask
  • 125 mlDistillation flask
  • ≤ 35 °CAmbient temperature
Ash Content Tester LACT-A10
  • {"Controlled\u00a0temperature":"775 \u00b125 \u2103","Temperature rising time of empty chamber":"\u2264 50 min","Furnace temperature uniformity":"\u2264 15\u2103","Internal dimension":"200 \u00d7 120 \u00d7 80 mm","External dimension":"490 \u00d7 490 \u00d7 450 mm","Power consumption":"2.5 kW","Power supply":"AC 220V \u00b110%, 50 Hz","Net weight":"35 kg"}Electric Muffle Furnace
  • {"Maximum control temperature":"1200 \u2103","Dimension":"500 \u00d7 300 \u00d7 235 mm","Power consumption":"5000 W","Power supply":"AC 220\u00b110% V, 50Hz","Net weight":"5 kg"}Temperature controller
  • {"Heating power":"(1 to 6) grades, continuously adjustable","Temperature":"400\u2103","Diameter of heating plate":"\u03a6 180 mm","Dimension":"280 \u00d7 250 \u00d7 90 mm","Power consumption":"2000 W","Power supply":"AC 220\u00b110%V, 50Hz"}Electric heating plate

Lubricating Oil Rust Characteristics Tester LRCT-A11

  • 4 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 1000 ± 50 rpmSpeed for sample stirring
  • Room temperature to 35°CAmbient temperature

Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10

  • 2 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 10 to 35°CAmbient temperature
  • Room Temperature to 100°CTemperature controlling range
Copper Strip Corrosion Tester LRCT-A13
  • 4 piecesSample hole
  • 4 to 12 piecesSample quantity
  • Room temperature to 35 °CAmbient temperature
  • Room temperature to 100°CTemperature controlling range
Automatic Tag Closed Flash Point Tester LACF-A10
  • -50 to 70°CExperimental temperature range
  • 50 mlTest sample volume
  • 10 to 40°CAmbient temperature range
  • ≤ 85%Humidity

Rotational Viscometer LRV-A10

  • 10 ~ 2000000 MPa•sViscosity measurement range
  • 5 °C ~ 35 °CAmbient temperature
  • Not more than 80 %Ambient humidity
  • Four spindles of No.1 ~ 4Spindles