Kinematics Viscometer LKV-A10

Kinematics Viscometer LKV-A10 is designed with hard glass bath and electric stirring device with 1200 rpm stirring motor. Designed as per ASTM D445 standard configuration, features ambient to 100°C of temperature range and 0 to 9999.9 s of time range. Compact design with RTD PT100 sensor for uniform bath temperature and 6 capillary Pinkevitch viscometer tubes, it is an ideal unit to determine kinematic viscosity of liquid petroleum products (Newtonian fluids) at a constant temperature.

  • Ambient temperature 15 to 35°C
    Relative humidity ≤ 85%
    Capillary viscometer 6 capillary Pinkevitch viscometer tubes
    Stirring motor 1200 rpm
    Temperature range Ambient to 100°C
    Temperature accuracy ±0.1℃
    Time range 0 to 9999.9 s
    Temperature sensor RTD PT100
    Capillary viscometer diameter 0.6 mm, 0.8 mm, 1mm, 1.2 mm, 1.5 mm, 2 mm
    Bath capacity 12 L
    Bath size Φ255×240 mm
    Dimension (W×D×H) 500×310×500 mm
    Net weight 11.5 kg
    • Hard glass bath, allow personnel to observe liquid flow
    • Electric stirring device with 1200 rpm stirring motor
    • Ambient to 100°C of temperature range and 0 to 9999.9 s of time range
    • RTD PT100 sensor for uniform bath temperature
    • 6 capillary Pinkevitch viscometer tubes with different inner diameters
    • Designed as per ASTM D445 standard configuration
    • An ideal unit to determine kinematic viscosity of liquid petroleum products (Newtonian fluids) at a constant temperature
  • Kinematics Viscometer is used to measure flow times for a fixed volume of fuel to flow under gravity through a capillary of the viscometer across the fields of petroleum and its products industries, research and development department etc.

Kinematics Viscometer LKV-A15

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A13

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A11

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A12
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Low Temperature Kinematic Viscosity Tester LKV-A14
  • ≤ 30 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 13 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A16

  • 0 ~ 40 ºCAmbient temperature
  • 20 ~ 90 %, RH while 40 ℃Relative humidity
  • ± 0.1 °CTemperature controlling accuracy
  • 0.0 s ~ 9999.9 sTiming range

Existent Gum Tester LEGT- B31

  • Aluminum block bath, φ260 × 130 mmEvaporation bath type and size
  • 3 piecesHoles for testing
  • φ51 × 70 mmSize of holes for testing cylinder
  • Flow meterFlow rate display

Existent Gum Tester LEGT- B32

  • Aluminum bath φ260 × 130 mmEvaporation bath type and size
  • 5 piecesHoles for testing
  • φ51 × 70 mmSize of holes for testing cylinder
  • 160 ℃ ~ 165℃Working temperature
Existent Gum Tester LEGT- B30
  • Oil bathBath type
  • 5000 ml ± 50 mlBath capacity
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
Automatic PMCC Flash Point Tester LCFP-A13
  • 10 °C ~ 40 ℃Ambient temperature
  • ≤ 80 %Relative humidity
  • electron igniter / gas flameIgnition Mode
  • Room Temperature ~ 300 ℃Temperature range

PMCC Flash Point Tester LCFP-A10

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °CTemperature range
  • 0.8 mmAperture of ignition device

Automatic PMCC Flash Point Tester LCFP-A11

  • 10 °C ~ 40 °CAmbient temperature
  • ≤ 80 %Relative humidity
  • Ambient Temperature ~ 250 °CMeasurement Range
  • Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °CFlash Point
Carbon Residue Tester (Ramsbottom) LRCT-B20
  • Metal furnaceCoking furnace
  • Electric heatingHeating mode
  • 5 unitsTest unit
  • Ambient to 550°CTemperature range
Carbon Residue Tester (CONRADSON METHODS) LRCT-B10
  • 30 mlPorcelain crucible
  • 75 mlInner iron crucible
  • 190 mlOuter iron crucible
  • Mig BurnerBurner

Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11

  • Four holes with a furnaceBath type
  • Electric resistance furnaceHeating type
  • 0 ~ 520 °CTemperature controlling range
  • ± 5 °CTemperature controlling accuracy

Acid Number Tester LAAT-A12

  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume
Water Soluble Acid and Alkali Tester LAAT-A10
  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature
Acid Number and Acidity Tester LAAT-A11
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption

Automatic Dielectric Tester LADT-A10

  • 2.0 kVACapacity
  • 2 k V/ sSpeed of voltage increase
  • 0.01Voltage inspection accuracy
  • < 0.1 kVBreakdown sensitivity