Low Temperature Kinematic Viscosity Tester LKV-A14

Labtron LKV-A14 Kinematic Viscometer is deliberately designed with advanced compressor refrigeration technology. It is highly efficient and made as per ASTM D445 “Test Methods for Kinematic Viscosity of Petroleum Products and Calculation of Dynamic Viscosity”.

  • Ambient temperature ≤ 30 °C
    Relative humidity ≤ 85 %
    Capillary viscometer 13 pieces
    Stirring motor 6 W, 1200 rpm
    Sample quantity
    Bath temperature
    Measurement range
    Bath cubage
    Temperature controlling range Ambient temperature ~ 70 °C
    Temperature controlling accuracy ± 0.1 °C
    Illumination 6 W / 220 V fluorescent lamp
    Constant temperature bath 5.8 L with stainless steel inner tank
    Timing range
    Barometric
    Timing accuracy
    Timing device
    Temperature sensor
    Inner capillary viscometer diameters 0.4, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 5.0 and 6.0 mm
    Mercury thermometer scale division
    • Minimal temperature is (-70) ℃.
    • It can do determination for two samples at a time
    • High work efficiency
    • Floor type machine
  • It is used in the fields of petroleum & its products industries, research and development department.

Kinematics Viscometer LKV-A16

  • 0 ~ 40 ºCAmbient temperature
  • 20 ~ 90 %, RH while 40 ℃Relative humidity
  • ± 0.1 °CTemperature controlling accuracy
  • 0.0 s ~ 9999.9 sTiming range

Kinematics Viscometer LKV-A12

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A10

  • 15 to 35°CAmbient temperature
  • ≤ 85%Relative humidity
  • 6 capillary Pinkevitch viscometer tubesCapillary viscometer
  • 1200 rpmStirring motor
Kinematics Viscometer LKV-A15
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A11
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A13

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Rotational Viscometer LRV-A10

  • 10 ~ 2000000 MPa•sViscosity measurement range
  • 5 °C ~ 35 °CAmbient temperature
  • Not more than 80 %Ambient humidity
  • Four spindles of No.1 ~ 4Spindles

Kinematics Viscometer LKV-A13

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A11
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A12
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Copper Strip Corrosion Tester LRCT-A13

  • 4 piecesSample hole
  • 4 to 12 piecesSample quantity
  • Room temperature to 35 °CAmbient temperature
  • Room temperature to 100°CTemperature controlling range

Lubricating Oil Rust Characteristics Tester LRCT-A11

  • 4 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 1000 ± 50 rpmSpeed for sample stirring
  • Room temperature to 35°CAmbient temperature
Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10
  • 2 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 10 to 35°CAmbient temperature
  • Room Temperature to 100°CTemperature controlling range
Solidifying Point Tester LLTT-A13
  • ± 0.5 ℃Temperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • Two holes in one trough, and same temperatureCold trough
  • ≤ 30 ℃Ambient temperature

Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15

  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity

Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

  • (-10)℃ ~ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 31.0 ~ 32.0 mmSample cup Inner diameter
  • 1.0 ~ 1.5 mmSample cup Wall thickness
Mercaptan Sulfur Tester LMST-A10
  • (0 to ±1999.5) MvPotential measuring range
  • 0.1 % ±0.5 mVIntrinsic error
  • Ri ≥1 × 1012 ΩInput impedance
  • 10 mLBurette capacity