Freezing Point Tester LLTT-A11

Freezing Point Tester LLTT-A11 is an advanced, automated and multipurpose freezing point tester, designed according to ASTM D1177,ASTM D2386 Standard Test Method for Freezing Point of Engine Coolant. Features freezing point range of -54°C to 2°C with cold bath measurement temperature range of -70° to 20°C, for freezing test point requirement. With floor-standing design, stainless-steel cold bath and double vacuum glass observation window, this freezing point tester is adopted with high precision temperature control technology, offers continuously adjustable mechanical sample stirring and electric bath liquid stirring. Equipped with imported refrigerator compressor comprised refrigeration system, this freezing point tester offers to measure jet fuel freezing point and engine coolant freezing point with automatic judging of freezing point temperature and high precision.

  • Freezing point range -54°C to 2°C
    Cold bath measurement temperature range -70° to 20°C
    Temperature controlling accuracy ±0.5°C
    Bath liquids stirring Electric
    Bath liquids stirring range 1200 r/min
    Sample stirring Mechanical stirring, continuously adjustable
    Sample stirring range 0 to 120 r/min
    Ambient temperature ≤ 30°C
    Relative humidity ≤ 85%
    Working bath material Stainless steel
    Observing window Double vacuum glass observing window
    Refrigerator system With imported refrigerator compressor
    Freezing point temperature judging Automatic
    Power supply AC 220 V ± 10%, 50/60 Hz
    Power 2000 W
    Dimension (W×D×H) 560×550×810 mm
    Net weight 49 kg
    • An advanced, automated and multipurpose freezing point tester
    • Designed according to ASTM D1177,ASTM D2386 Standard Test Method
    • Continuously adjustable mechanical sample stirring and electric bath liquid stirring
    • Freezing point range of -54°C to 2°C
    • Cold bath measurement temperature range of -70° to 20°C
    • Floor-standing design with stainless steel work table-board
    • Stainless-steel cold bath with double vacuum glass observation window
    • Adopted with high precision temperature control technology
    • Can measure jet fuel freezing point and engine coolant freezing point
    • Automatic judging of freezing point temperature
    • Refrigeration system with imported refrigerator compressor
    • Fast cooling with high precision
  • Freezing Point Tester is used to precisely determine the freezing point of aviation fuels, engine coolants, antifreeze products, brake fluids and other petroleum products.

  • Double walled tube × 2 pcs
    Tube plug × 2 pcs
    Temperature sensor × 2 pcs
    Stainless steel spiral tube agitator × 2 pcs
    Bath cover × 2 pcs
    Single walled tube × 1 pc
    Test tube stand × 1 set

Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15

  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity

Solidifying Point Tester LLTT-A13

  • ± 0.5 ℃Temperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • Two holes in one trough, and same temperatureCold trough
  • ≤ 30 ℃Ambient temperature

Pour and Cloud Point Tester LLTT-A14

  • 2 chambersChamber quantity
  • Ambient to -51 ℃Chamber 01 temperature control
  • Ambient to -65 ℃Chamber 02 temperature control
  • ±1°CTemperature precision
Solidifying Point Tester (Solidifying Point and Cold Filter Plugging Point) LLTT-A21
  • New-type refrigeration compressorRefrigeration system
  • One trough with two baths, temperatures in two baths are equalCold trough
  • Room temperature ~ (-70) °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
Solidifying Point Tester ('-20°C +80°C') LLTT-A22
  • ± 0.5 °CTemperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • One trough with two baths, temperatures in two baths are equalCold trough
  • Room temperature ~ (-70) °CControlling temperature of cold trough

Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

  • (-10)℃ ~ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 31.0 ~ 32.0 mmSample cup Inner diameter
  • 1.0 ~ 1.5 mmSample cup Wall thickness

Automatic Pour Point Tester LLTT-A23

  • ≤ 30 ℃Ambient temperature
  • > 40 °C / 10 minRefrigeration speed
  • ≤ 2 °CRepeatability for solidifying point
  • ≤ 3 °CRepeatability for pour point

Solidifying Point Constant Temperature Water Bath LLTT-A10

  • 20 LCapacity
  • Ambient +5°C to 100°CTemperature range
  • ± 0.1℃Precision
  • 1200 r/minStirring range
Solidifying Point Tester LLTT-A20
  • ± 0.5 °CTemperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • One trough with two baths, temperatures in two baths are equalCold trough
  • Room temperature ~ (-70) °CControlling temperature of cold trough
Multifunctional Low Temperature Tester LLTT-A16
  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity

Aniline Point Tester LAPT-A11

  • ≤ 0.5 ℃Temperature controlling accuracy
  • Room temperature ~ 200 ℃Temperature controlling range
  • 5 VPower supply for illumination
  • 2 kWPower of motor

Aniline Point Tester LAPT-A10

  • Room temperature ~ 150°CMeasurement range
  • 0 ~ 1200 r / minStirring speed
  • 25 WHeating power
  • 360 × 250 × 545 mmInterior Dimension
Constant Temperature Needle Penetration Tester LTNP-A10
  • 0 to 700 taper degree (digital display table 0-70 mm)Measuring range
  • Timing error is less than ±0.1 sTiming device
  • 0.01 mm Resolution
  • ±1 cone insertion degreeNeedle insertion accuracy
Automatic Softening Point Tester LSPT-A10
  • 32 ℃ to 160 ℃Measurement range
  • 35 °CAmbient temperature
  • 0.01 ℃Temperature resolution
  • 1000 mLBeaker volume

Insulating Oil Breakdown Voltage Tester LIBT-A23

  • AC 220 V ± 5 % , 50HzPower supply
  • 0 ~ 75 kVMeasurement range
  • 3 kV ± 10 % / sVoltage rising rate
  • 2.5 mmDistance between electrodes

Wax Oil Content Tester LWCT-A22

  • AC 220 V ± 10 %, 50 HzPower supply
  • RT ~ 90 ℃ ± 5 ℃Temperature controlling range in water bath
  • (-35) ℃ ± 1 ℃Cooling bath temperature
  • 35 ℃ ± 1 ℃Evaporation temperature
Mechanical Impurity Tester (Weight Method) LMIT-A21
  • 390 x 260 x 590 mmDimension
  • ≤ 1200 WTotal power consumption
  • AC 220 V ± 10 %, 50 HzPower supply
  • 1000 WHeating power of water bath
Specific Gravity Tester LSGT-A10
  •  4000 ml × 2Vessel Volume
  • 160 WPower of Vacuum pump
  • 3.7 kPa(27.75 mmHg)Negative power
  • 30 WPower of shaking machine