Base Number Tester LAAT-A13

Labtron LAAT-A13 is composed of automatic potential titrator and titration device. It is designed according to Industry Standard of Petrochemical and follows ASTM D2896 and ASTM D4739"Test Methods for Base Number of Petroleum Products".

  • Graduated flask
    Conical flask
    Separatory funnel
    Volumetric analysis Titration condensation: 0.1 N;<br> Controlling accuracy: ≤ ± 0.02 ml
    Automatic acid titration Titration condensation: 0.1 N;<br> Controlling accuracy: ≤ ± 0.1 pH
    Automatic potential control Titration condensation: 0.1 N;<br> Controlling accuracy: ≤ 10 mV
    Measurement range
    Potential measurement range
    Burette volume
    Minimum titration volume
    Burette precision
    Precision
    Ambient temperature 0 ~ 35 ℃
    Relative humidity ≤ 85 %
    Temperature compensation Manual compensation; 5 ~ 60 ℃
    Preset adjustment range of end point pH 1 to 13 or ± 100 ~ 1300 mV
    Preset controlling range for titration 1 ~ 3 pH or 100 ~ 300 mV from end point
    Precision of titration tube
    Test tube
    Acidometer Full scale
    Acidometer Accuracy
    Heating power
    Total power consumption
    Power supply AC 220 V ± 10 %, 50 Hz
    Dimension
    Net weight
    • Adopts principle of acid-alkali neutralization
    • Wide measuring range
    • High accuracy
    • Easy operation
  • It is used to determine and calculate base number of sample based on acid-alkali neutralization principle, perchloric and acid potentiometric titration methods and potential changes to detect end point

Acid Number and Acidity Tester LAAT-A11

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption

Water Soluble Acid and Alkali Tester LAAT-A10

  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature

Acid Number Tester LAAT-A12

  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume

Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11

  • Four holes with a furnaceBath type
  • Electric resistance furnaceHeating type
  • 0 ~ 520 °CTemperature controlling range
  • ± 5 °CTemperature controlling accuracy

Carbon Residue Tester (CONRADSON METHODS) LRCT-B10

  • 30 mlPorcelain crucible
  • 75 mlInner iron crucible
  • 190 mlOuter iron crucible
  • Mig BurnerBurner
Carbon Residue Tester (Ramsbottom) LRCT-B20
  • Metal furnaceCoking furnace
  • Electric heatingHeating mode
  • 5 unitsTest unit
  • Ambient to 550°CTemperature range
Automatic Softening Point Tester LSPT-A10
  • 32 ℃ to 160 ℃Measurement range
  • 35 °CAmbient temperature
  • 0.01 ℃Temperature resolution
  • 1000 mLBeaker volume

Automatic Tag Closed Flash Point Tester LACF-A10

  • -50 to 70°CExperimental temperature range
  • 50 mlTest sample volume
  • 10 to 40°CAmbient temperature range
  • ≤ 85%Humidity

Automatic Thermogravimetric Analyzer LTGA-A10

  • Room temperature to 1000 ºC Temperature range
  • 0.1 ºCTemperature resolution
  • ±0.1 ºCTemperature fluctuation
  • 1 ~ 80 ºC / minHeating rate
Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15
  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity
Solidifying Point Tester LLTT-A13
  • ± 0.5 ℃Temperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • Two holes in one trough, and same temperatureCold trough
  • ≤ 30 ℃Ambient temperature

Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

  • (-10)℃ ~ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 31.0 ~ 32.0 mmSample cup Inner diameter
  • 1.0 ~ 1.5 mmSample cup Wall thickness