Penetrometer LMPT-A13

Penetrometer LMPT-A13 is a fully automatic unit for determining needle penetration of highway bitumen, modified asphalt, as well as liquid petroleum asphalt or residue of emulsified asphalt after evaporation material. It has 0.6 penetration measurement accuracy with stable test repeatability. Automatic drawing and print of nomogram of asphalt penetration with special designed computer drawing software and data accurate reading technology. Consists of automatic lifting device for penetration measurement. It is ideally used for petroleum, emulsified asphalt and highway bitumen, etc.

  • Measurement range 0 to 600 penetration scale
    Timing range 0 sec to 60 sec
    Time accuracy error ≥ ± 0.1 seconds
    Resolution 0.1 penetration
    Power consumption 200 W
    Power supply AC 220 V ± 10 %, 50 Hz
    Needle diameter 50 mm
    Sample container (D × H) 55 mm × 35 mm
    Dimensions (L × W × H) 260 × 400 × 600 mm
    Standard weight 50 g
    Weight of standard needle 2.5 ± 0.05 g
    Net Weight 15 kg
    • Measurement accuracy reaches up to 0.6 penetrations
    • Equipped with high resolution capacitance touch screen
    • Installed specific computer drawing software and data accurate reading technology
    • Automatic draw and printing of nomogram of asphalt penetration
    • Equipped with automatic lifting device
    • Stable test repeatability with new detection unit
  • Widely used for determining needle penetration of highway bitumen, modified asphalt, as well as liquid petroleum asphalt or residue of emulsified asphalt after evaporation.

Penetrometer LMPT-A10

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Penetrometer LMPT-A11

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec or 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Penetrometer LMPT-A12

  • {"Measurement range":"0 to 600 penetration scale","Timing controller":"5 sec or 60 sec","Time accuracy":"\u00b1 0.1 seconds","Resolution":"0.1 penetration","Penetration accuracy":"\u00b1 1 penetration","Weight of standard needle":"2.5 \u00b1 0.05 g","Dimensions (W \u00d7 L \u00d7 H)":"700 \u00d7 400 \u00d7 750 mm","Weight":"30 kg"}Penetrometer
  • {"Bath volume":"3.5 L","Temperature range":"5 \u00b0C to 60 \u00b0C","Temperature accuracy":"\u00b1 0.1 \u00b0C","Circulatory water quantity":"3 L\/minute","Pump Lift":"2 m","Power consumption":"1200 W","Power supply":"AC 220V \u00b1 10 %, 50 Hz","Dimensions (W \u00d7 L \u00d7 H)":"600 \u00d7 400 \u00d7 650 mm","Weight":"40 kg"}Circulatory Water Bath

Open Cup Flash Point Tester LOFP-A10

  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity

Automatic COC Flash & Fire Point Tester LOFP-B10

  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability
Cleveland Open Cup Flash Point Tester LOFP-A11
  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature
Water Content Tester LWT-A11
  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination

Coulometric Karl Fischer Titrator LWT-A30

  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed

Water Content Tester LWT-A10

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination
Automatic Bomb Calorimeter LABC-A10
  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • The outer barrel temperature is constantOperation Mode
Automatic Bomb Calorimeter LABC-A11
  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant modeOperation Mode

Automatic Bomb Calorimeter LABC-B10

  • IsoperibolCalorimeter type
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & loweringOxygen filling
  • 250 mlBomb volume
  • < 8 min full test process: <10 minAnalysis time

Density Tester LDMT-A10

  • Ф300 × 380 mmCubage of bath
  • 0 °C ~ 100 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
  • Industrial platinum resistance, Pt100Temperature sensor
Foaming Characteristics Tester LFCT-A10
  • Ambient to 100°CTemperature Range
  • ± 0.1°CTemperature Precision
  • 94 mL ± 5 mL/min, with flowmetersAir Flow
  • 0 to 99 min 59 s, resolution 1 sTiming Unit