Rust Characteristics and Corrosion Tester LRCT-A12

Rust Characteristics and Corrosion Tester LRCT-A12 is a multifunctional tester with high performance cost ratio. It is designed and made as per the International Standards ASTM D665 (Test Methods for Rust-Preventing Characteristics of Inhibited Mineral Oil in the Presence of Water), ASTM D130 (Test Methods for Detection of Copper Corrosion from Petroleum Products by the Copper Strip Tarnish Test) and ASTM D7671 (Test Methods for Detecting Silver Corrosion from Jet Fuels by the Sliver Strip Test).

  • Sample hole 4 pieces
    Ambient temperature Room temperature to 35°C
    Temperature controlling range 0 to 100°C
    Temperature controlling accuracy ± 1°C
    Relative humidity ≤ 85 %
    Timing range 1 min to 24 hours
    Total power consumption ≤ 1800W
    Dimensions 880 × 430 × 960 mm, 590 × 490 × 430 mm
    Power supply AC 220 V ± 10 %, 50 Hz
    • LCD temperature controller
    • LED digital display for time
    • High performance cost ratio
    • Heater and electric stirrer to maintain the bath constantly
  • It is used to determine corrosiveness aviation gasoline, kerosene, turbine oil, vehicle gasoline, tractor fuels, washing solvent, distillate fuels, lubricating oil and other petroleum products.

Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10

  • 2 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 10 to 35°CAmbient temperature
  • Room Temperature to 100°CTemperature controlling range

Lubricating Oil Rust Characteristics Tester LRCT-A11

  • 4 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 1000 ± 50 rpmSpeed for sample stirring
  • Room temperature to 35°CAmbient temperature

Copper Strip Corrosion Tester LRCT-A13

  • 4 piecesSample hole
  • 4 to 12 piecesSample quantity
  • Room temperature to 35 °CAmbient temperature
  • Room temperature to 100°CTemperature controlling range

Oxygen Bomb Calorimeter LBC-C20

  • 14000 ~ 15000 J / KHeat capacity
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb

Oxygen Bomb Calorimeter LBC-C21

  • 10 ℃ ~ 35 ℃Temperature controlling range
  • 0.001 ℃Temperature resolution
  • 15 kJ / KMean value of heat capacity
  • 20 ℃ ± 5 ℃Ambient temperature
Oxygen Bomb Calorimeter LBC-C22
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
  • 15 ~ 28 ℃Operation environment temperature
Vapor Pressure Tester (REID METHOD) LVPT-C10
  • RT ~ 90 °COperation temperature of water bath
  • ± 0.1 °CTemperature controlling accuracy
  • 550 × 520 × 102 mmDimensions
  • ± 0.4 % kPaPressure meter accuracy

Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11

  • Two samples or a group of parallel samplesTest bomb
  • 37.8 °CBath temperature
  • 0.1 °CTemperature controlling accuracy
  • 500 × 560 × 680 mm, 950 × 540 × 720 mmDimensions

Existent Gum Tester LEGT- B31

  • Aluminum block bath, φ260 × 130 mmEvaporation bath type and size
  • 3 piecesHoles for testing
  • φ51 × 70 mmSize of holes for testing cylinder
  • Flow meterFlow rate display
Existent Gum Tester LEGT- B32
  • Aluminum bath φ260 × 130 mmEvaporation bath type and size
  • 5 piecesHoles for testing
  • φ51 × 70 mmSize of holes for testing cylinder
  • 160 ℃ ~ 165℃Working temperature
Existent Gum Tester LEGT- B30
  • Oil bathBath type
  • 5000 ml ± 50 mlBath capacity
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity

Penetrometer LMPT-A10

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Penetrometer LMPT-A12

  • {"Measurement range":"0 to 600 penetration scale","Timing controller":"5 sec or 60 sec","Time accuracy":"\u00b1 0.1 seconds","Resolution":"0.1 penetration","Penetration accuracy":"\u00b1 1 penetration","Weight of standard needle":"2.5 \u00b1 0.05 g","Dimensions (W \u00d7 L \u00d7 H)":"700 \u00d7 400 \u00d7 750 mm","Weight":"30 kg"}Penetrometer
  • {"Bath volume":"3.5 L","Temperature range":"5 \u00b0C to 60 \u00b0C","Temperature accuracy":"\u00b1 0.1 \u00b0C","Circulatory water quantity":"3 L\/minute","Pump Lift":"2 m","Power consumption":"1200 W","Power supply":"AC 220V \u00b1 10 %, 50 Hz","Dimensions (W \u00d7 L \u00d7 H)":"600 \u00d7 400 \u00d7 650 mm","Weight":"40 kg"}Circulatory Water Bath
Penetrometer LMPT-A11
  • 0 to 600 penetration scaleMeasurement range
  • 5 sec or 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution
Acid Number and Acidity Tester LAAT-A11
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption

Acid Number Tester LAAT-A12

  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume

Water Soluble Acid and Alkali Tester LAAT-A10

  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature