Distillation Tester (low temperature single unit) LDT-A17

Distillation Tester (low temperature single unit) LDT-A17 is a single distillation system with advanced refrigerator compressor. It is devised according to (Test Methods for Distillation Characteristics of Petroleum Products at Barometric Pressure) as per ASTM D86.

  • Graduated flasks 100 ml
    Distillation flask 125 mL
    Ambient temperature ≤ 30 °C
    Relative humidity ≤ 85 %
    Temperature controlling range 0 °C to 60 °C
    Temperature controlling accuracy ± 0.5 °C
    Thermometer (-2 )°C to 300 ℃ and (-2) °C to 400 ℃
    Division value 1°C
    Scale division 1 ml
    Inner diameter of electric furnace φ32 mm, φ38 mm
    Outer diameter of electric furnace φ50 mm
    Dimension 720 x 590 x 660 mm
    Heating power system 1000 W
    Total power consumption ≤ 2500 W
    Power supply AC 220 V ± 10 %, 50 Hz
    • Total immersion rod type Thermometer
    • LED Digital display
    • Digital temperature controller, heater, refrigeration device and stirrer
    • Adjustable heating power
  • It is used to determine distillation characteristics of gasoline, aviation gasoline, jet fuels, special boiling point solvent, naphtha, diesel oil, distillate and similar petroleum products.

Distillation Tester Dual Units LDT-A15

  • 100 mlGraduated flasks
  • 1mlScale division of graduated flask
  • 125 mlDistillation flask
  • ≤ 35 °CAmbient temperature

Vacuum Distillation Tester LDT-A13

  • 5 °C to 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 1000 mlCubage of buffer vessel
  • ≤ 2 mm HgMax. Residual pressure

Distillation Tester LDT-A12

  • 100 mlGraduated flasks
  • 1 mlScale division of graduated flask
  • φ65Outer diameter of distillation flask
  • φ14Refrigeration tube
Benzene Distillation Tester (Low Temperature) LDT-A11
  • -10°C to 35°CAmbient temperature
  • ≤ 85 %Relative humidity
  • Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°CThermometer
  • 0.1 ℃Scale division
Distillation Tester (low temperature Double units) LDT-A16
  • 100 mlGraduated flasks
  • 125 mlDistillation flask
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity

Distillation Tester LDT-A10

  • 10 ml and 100 mlGraduated flasks
  • 10 ml is 0.1 ml and 100 ml is 1 mlScale division of graduated flask
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity

Automatic Distillation Apparatus LADA-A10

  • 2 kWHeating power
  • 0.5 kWCooling power
  • 0 to 400℃Steam temperature
  • 0 to 500℃Oven temperature

Distillation Tester Front Type LDT-A14

  • 125 mLDistillation flask
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • (-2 )°C to 300 ℃ and (-2) °C to 400 ℃Thermometer

Penetrometer LMPT-A11

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec or 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Penetrometer LMPT-A12

  • {"Measurement range":"0 to 600 penetration scale","Timing controller":"5 sec or 60 sec","Time accuracy":"\u00b1 0.1 seconds","Resolution":"0.1 penetration","Penetration accuracy":"\u00b1 1 penetration","Weight of standard needle":"2.5 \u00b1 0.05 g","Dimensions (W \u00d7 L \u00d7 H)":"700 \u00d7 400 \u00d7 750 mm","Weight":"30 kg"}Penetrometer
  • {"Bath volume":"3.5 L","Temperature range":"5 \u00b0C to 60 \u00b0C","Temperature accuracy":"\u00b1 0.1 \u00b0C","Circulatory water quantity":"3 L\/minute","Pump Lift":"2 m","Power consumption":"1200 W","Power supply":"AC 220V \u00b1 10 %, 50 Hz","Dimensions (W \u00d7 L \u00d7 H)":"600 \u00d7 400 \u00d7 650 mm","Weight":"40 kg"}Circulatory Water Bath
Penetrometer LMPT-A10
  • 0 to 600 penetration scaleMeasurement range
  • 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution
Kinematics Viscometer LKV-A12
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A11

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A13

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Existent Gum Tester LEGT- B31
  • Aluminum block bath, φ260 × 130 mmEvaporation bath type and size
  • 3 piecesHoles for testing
  • φ51 × 70 mmSize of holes for testing cylinder
  • Flow meterFlow rate display
Existent Gum Tester LEGT- B30
  • Oil bathBath type
  • 5000 ml ± 50 mlBath capacity
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity

Existent Gum Tester LEGT- B32

  • Aluminum bath φ260 × 130 mmEvaporation bath type and size
  • 5 piecesHoles for testing
  • φ51 × 70 mmSize of holes for testing cylinder
  • 160 ℃ ~ 165℃Working temperature

Mercaptan Sulfur Tester LMST-A10

  • (0 to ±1999.5) MvPotential measuring range
  • 0.1 % ±0.5 mVIntrinsic error
  • Ri ≥1 × 1012 ΩInput impedance
  • 10 mLBurette capacity
Benzene Distillation Tester (Low Temperature) LDT-A11
  • -10°C to 35°CAmbient temperature
  • ≤ 85 %Relative humidity
  • Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°CThermometer
  • 0.1 ℃Scale division
Automatic Distillation Apparatus LADA-A10
  • 2 kWHeating power
  • 0.5 kWCooling power
  • 0 to 400℃Steam temperature
  • 0 to 500℃Oven temperature

Distillation Tester Dual Units LDT-A15

  • 100 mlGraduated flasks
  • 1mlScale division of graduated flask
  • 125 mlDistillation flask
  • ≤ 35 °CAmbient temperature