Distillation Tester LDT-A10

Distillation Tester LDT-A10 is a desktop device, automated and can withstand a very high temperature. It is designed according to (Test Methods for Distillation Characteristics of Petroleum Products) as per ASTM D86.

  • Graduated flasks 10 ml and 100 ml
    Scale division of graduated flask 10 ml is 0.1 ml and 100 ml is 1 ml
    Ambient temperature (-10) °C ~ 35 °C
    Relative humidity ≤ 85 %
    Thermometer 0 °C ~ 360 °C
    Scale division 1 °C
    Inner diameter of electric furnace Ф50 mm, Ф30 mm and with a gap
    Outer diameter of electric furnace Ф105 mm
    Refrigeration tube Made of copper tube of ф16 × 1
    Angle between refrigeration tube and water level 15°
    Length of refrigeration tube 555 ± 3 mm
    Size of refrigeration bath 180 x 100 x 150 mm
    Ball diameter of flask Ф69 ± 1 mm
    Neck diameter of flask Ф16 ± 1 mm
    Angle between branch tube and neck 75° ± 3°
    Dimension 790 x 360 x 710 mm
    Heating power system 1000 W / 220 V
    Total power consumption ≤ 1100 W
    Power supply AC 220 V ± 10 %, 50 Hz
    • Alterable heating rate
    • Distillation flask sustains temperature more than 500 °C
    • Two graduated flasks
    • Temperature adjustment circuit
  • It is used to determine distillate of engine fuel, solvent oil and light petroleum products.

Distillation Tester (low temperature single unit) LDT-A17

  • 100 mlGraduated flasks
  • 125 mLDistillation flask
  • ≤ 30 °CAmbient temperature
  • ≤ 85 %Relative humidity

Benzene Distillation Tester (Low Temperature) LDT-A11

  • -10°C to 35°CAmbient temperature
  • ≤ 85 %Relative humidity
  • Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°CThermometer
  • 0.1 ℃Scale division

Distillation Tester Dual Units LDT-A15

  • 100 mlGraduated flasks
  • 1mlScale division of graduated flask
  • 125 mlDistillation flask
  • ≤ 35 °CAmbient temperature
Distillation Tester (low temperature Double units) LDT-A16
  • 100 mlGraduated flasks
  • 125 mlDistillation flask
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
Vacuum Distillation Tester LDT-A13
  • 5 °C to 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 1000 mlCubage of buffer vessel
  • ≤ 2 mm HgMax. Residual pressure

Distillation Tester LDT-A12

  • 100 mlGraduated flasks
  • 1 mlScale division of graduated flask
  • φ65Outer diameter of distillation flask
  • φ14Refrigeration tube

Automatic Distillation Apparatus LADA-A10

  • 2 kWHeating power
  • 0.5 kWCooling power
  • 0 to 400℃Steam temperature
  • 0 to 500℃Oven temperature

Distillation Tester Front Type LDT-A14

  • 125 mLDistillation flask
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • (-2 )°C to 300 ℃ and (-2) °C to 400 ℃Thermometer

Automatic Dielectric Tester LADT-A10

  • 2.0 kVACapacity
  • 2 k V/ sSpeed of voltage increase
  • 0.01Voltage inspection accuracy
  • < 0.1 kVBreakdown sensitivity

Specific Gravity Tester LSGT-A10

  •  4000 ml × 2Vessel Volume
  • 160 WPower of Vacuum pump
  • 3.7 kPa(27.75 mmHg)Negative power
  • 30 WPower of shaking machine
Ash Content Tester LACT-A10
  • {"Controlled\u00a0temperature":"775 \u00b125 \u2103","Temperature rising time of empty chamber":"\u2264 50 min","Furnace temperature uniformity":"\u2264 15\u2103","Internal dimension":"200 \u00d7 120 \u00d7 80 mm","External dimension":"490 \u00d7 490 \u00d7 450 mm","Power consumption":"2.5 kW","Power supply":"AC 220V \u00b110%, 50 Hz","Net weight":"35 kg"}Electric Muffle Furnace
  • {"Maximum control temperature":"1200 \u2103","Dimension":"500 \u00d7 300 \u00d7 235 mm","Power consumption":"5000 W","Power supply":"AC 220\u00b110% V, 50Hz","Net weight":"5 kg"}Temperature controller
  • {"Heating power":"(1 to 6) grades, continuously adjustable","Temperature":"400\u2103","Diameter of heating plate":"\u03a6 180 mm","Dimension":"280 \u00d7 250 \u00d7 90 mm","Power consumption":"2000 W","Power supply":"AC 220\u00b110%V, 50Hz"}Electric heating plate
Oxygen Bomb Calorimeter LBC-C22
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
  • 15 ~ 28 ℃Operation environment temperature

Oxygen Bomb Calorimeter LBC-C20

  • 14000 ~ 15000 J / KHeat capacity
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb

Oxygen Bomb Calorimeter LBC-C21

  • 10 ℃ ~ 35 ℃Temperature controlling range
  • 0.001 ℃Temperature resolution
  • 15 kJ / KMean value of heat capacity
  • 20 ℃ ± 5 ℃Ambient temperature
Mercaptan Sulfur Tester LMST-A10
  • (0 to ±1999.5) MvPotential measuring range
  • 0.1 % ±0.5 mVIntrinsic error
  • Ri ≥1 × 1012 ΩInput impedance
  • 10 mLBurette capacity