Coulometric Karl Fischer Titrator LWT-A31

Coulometric Karl Fischer Titrator LWT-A31 is a benchtop unit with 5 to 40°C ambient temperature range, 3 µg to 9999.9 µg measurement range, and offers 400 mA maximum current. Excellent low-power operation makes it possible to compact battery, enables portable function criterion for measuring electrode signal for the electrolysis end. It stability and accuracy are key factors affecting the measurement accuracy. Designed with streamline and 5 inch coloured touch screen with standard testing method used ASTMD4928, ASTMD1533 and ASTMD6304 in titration process.

  • Maximum current 400 mA
    Measurement range 3 µg to 9999.9 µg
    Resolution 0.1 µg
    Precision 1 ± 2 µg (3µg H<sub>2</sub>O to 20µg H<sub>2</sub>O)
    Precision 2 ± 3 µg (20µg H<sub>2</sub>O to 100µg H<sub>2</sub>O)
    Precision 3 ≤ 5 % (100µg H<sub>2</sub>O to 10mg H<sub>2</sub>O)
    Data saving 496 pcs
    Built-in printer Thermal printer
    Calculation formula 8 kinds can be selected
    Ambient temperature 5 to 40°C
    Dimension 400 × 260 × 180 mm
    Power consumption 50 W
    Power Supply AC 220 V±10%, 50Hz ±5 %
    Net weight 5 kg
    • Design with streamline and 5 inch coloured touch screen
    • Electrolytic process is intelligently control completely
    • It adopts real-time dynamic impedance method to detect the end point of titration
    • Equipped with open-circuit fault, short-circuit fault and measuring electrode
    • High-precision, and it has automatic detection function
    • Inbuilt thermal printer and end point is settable
  • Coulometric Karl Fischer Titrator is widely used to determine the trace water content in liquid petroleum, chemical engineering, pharmacy, electricity, scientific research and education department.

  • Accessories no. Name Qty
    1 Main unit 1 set
    2 Titration cell 1 set
    3 Power cord 1 piece
    4 Printing paper 2 rolls
    5 Syringe 0.5 µl 1 piece
    6 Syringe 50 µl 1 piece
    7 Syringe 1 ml 1 piece
    8 Needle 2 piece
    9 Stirrer 2 piece
    10 Vacuum grease 5 piece
    11 Silicone pad 1 set
    12 Allochroic silica gel 1 package
    13 Electrolyte 1 bottle
    14 Fuse 2 pieces

Water Content Tester LWT-A10

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination

Coulometric Karl Fischer Titrator LWT-A30

  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed

Water Content Tester LWT-A11

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination
Crude Petroleum Water Content Tester LWT-B10
  • -10 to 35°CAmbient Temperature Range
  • ≤85%Relative Humidity
  • 1000 mlDistillation Flask
  • 5 ml, with 0.05 ml graduationReceiver

Kinematics Viscometer LKV-A12

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A13

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A11
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Automatic Thermogravimetric Analyzer LTGA-A10
  • Room temperature to 1000 ºC Temperature range
  • 0.1 ºCTemperature resolution
  • ±0.1 ºCTemperature fluctuation
  • 1 ~ 80 ºC / minHeating rate

Rotational Viscometer LRV-A10

  • 10 ~ 2000000 MPa•sViscosity measurement range
  • 5 °C ~ 35 °CAmbient temperature
  • Not more than 80 %Ambient humidity
  • Four spindles of No.1 ~ 4Spindles

Automatic Dielectric Tester LADT-A10

  • 2.0 kVACapacity
  • 2 k V/ sSpeed of voltage increase
  • 0.01Voltage inspection accuracy
  • < 0.1 kVBreakdown sensitivity
Automatic Tag Closed Flash Point Tester LACF-A10
  • -50 to 70°CExperimental temperature range
  • 50 mlTest sample volume
  • 10 to 40°CAmbient temperature range
  • ≤ 85%Humidity