Double Beam UV-Vis Spectrophotometer LUS-B13

Double Beam UV-Vis Spectrophotometer LUS-B13 is a compact, tabletop double beam designed UV-Vis spectrophotometer comprising Silicon photodiode detector, Tungsten and Deuterium lamp as light source. Equipped with wide wavelength range of 190 nm to 1100 nm, it offers 1.0 nm of bandwidth with automatic setting of wavelength. Designed with 6 inches LCD display, import source and receiver system, it provides rich measurement methods with high performance and reliability.

  • Wavelength Range 190 to 1100 nm
    Spectral Bandwidth 1.0 nm
    Optical System Double beam
    Wavelength Accuracy ±0.3 nm
    Wavelength Repeatability ≤0.1 nm
    Wavelength Resolution 0.1 nm
    Photometric Display Range -4 to 4 A
    Photometric Mode T, A, C, E
    Photometric Accuracy ±0.3% τ (0 to 100%τ) ± 0.002 A (0 to 0.5 A) ± 0.003 A (0.5 A to 1 A)
    Photometric Repeatability 0.15% τ (0 to 100% τ) ± 0.001 A (0 to 0.5 A) ± 0.0015 A (0.5 A to 1 A)
    Light Source Tungsten lamp, Deuterium lamp
    Stray Light ≤0.03% τ (220 nm NaI, 340 nm NaNO<sub>2</sub>)
    Stability 0.0005 A/h @500 nm
    Noise ± 0.002 A @500 nm
    Display 6 inches high brightness Blue LCD display
    Baseline Flatness ± 0.001 A
    Detector Silicon photodiode
    Power Supply AC 220/110 V, 50/60 Hz
    Dimensions (L×W×H) 560×450×230 mm
    Net Weight 28 kg
    • Compact, tabletop double beam designed UV-Vis spectrophotometer
    • Silicon photodiode detector, Tungsten and Deuterium lamp as light source
    • Wide wavelength range of 190 nm to 1100 nm with automatic setting
    • 6 inches high brightness blue LCD display
    • Import source and receiver system
    • Measurement methods: wavelength scan, time scan, multi-wavelength determination, multi-order derivative determination, dual-wavelength, three-wavelength, DNA protein measurements etc.
    • High performance and reliability with user-friendly interface
  • Double Beam UV-Visible Spectrophotometer are used for analysis of band gap, optical coatings and thin films, quantitative analyses, kinetics, wavelength scanning, and DNA and Protein analysis across biological research, bio-industry, pharmaceutical analysis, pharmaceutical, teaching and research, environmental protection, food hygiene, clinical examination, health and epidemic prevention and other fields.

Related Products of Double Beam UV/Vis Spectrophotometer

Labtron Double Beam UV/Vis Spectrophotometer offer automatic wavelength adjustments with their silicon photodiode detectors. Their dual beam designs cover a broad wavelength range. They support multiple measurement methods to meet diverse analytical requirements. Our spectrophotometer ensures precise results and ease of use with auto calibration, user-friendly interfaces, and advanced optics.

Double Beam UV-Vis Spectrophotometer LUS-B40

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4 nmSpectral bandwidth
  • ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full rangeWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Double Beam UV/Vis Spectrophotometer LUS-B32

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Double Beam UV/Vis Spectrophotometer LUS-B30

  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Double Beam UV-Vis Spectrophotometer LUS-B11
  • 190 to 1100 nmWavelength range
  • 1.8 nmSpectral bandwidth
  • Double beam; 1200 lines/mm gratingOptical system
  • ±0.1nm (D2 656.1nm), ±0.3nm @ allWavelength accuracy
Double Beam UV-Vis Spectrophotometer LUS-B10
  • 190 to 1100 nmWavelength Range
  • 1.8 nmSpectral Bandwidth
  • Double beamOptical System
  • ±0.3 nmWavelength Accuracy

Double Beam UV/Vis Spectrophotometer LUS-B16

  • 190 ~ 1100 nmWavelength Range
  • AutomaticSetting Wavelength
  • 0.5 / 1.0 / 2.0 / 4.0 nm adjustableSpectral Bandwidth
  • ± 0.3 nmWavelength Accuracy

Double Beam UV-Vis Spectrophotometer LUS-B20

  • 190 to 1100 nmWavelength range
  • 1.0 to 5.0 nm (adjustable)Spectral bandwidth
  • Double beam, C-T monochromator, 1600 L/mm holographic gratingOptical system
  • ±0.3 nmWavelength accuracy

Double Beam UV-Vis Spectrophotometer LUS-B12

  • 190 to 1100 nmWavelength Range
  • 1.8 nmSpectral Bandwidth
  • Split double beam, C-T monochromator,1200 L/mm holographic gratingOptical System
  • ±0.5nmWavelength Accuracy
Double Beam UV/Vis Spectrophotometer LUS-B31
  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Double beam UV-Visible Spectrophotometer LUS-B15
  • 190 ~ 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • 0.5 nmWavelength accuracy
  • ≤ 0.2 nmWavelength repeatability

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer designed for accurate elemental analysis. Each of them features integrated flame and graphite furnace atomization systems, automatic wavelength scanning, and peak searching capabilities. Safety alarms ensure secure operation. Our Atomic Absorption Spectrophotometer delivers reliable results across a wide range of wavelengths with precise optics and temperature control.

Atomic Absorption Spectrophotometer LAAS-A11

  • 190 - 900 nmWavelength range
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nmSpectral Bandwidth
  • ≤ ± 0.5 nmWavelength accuracy
  • ≤ 0.3 nm(single direction)Wavelength repeatability

Atomic Absorption Spectrophotometer LAAS-A20

  • 180 - 900 nmWavelength range
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability
Atomic Absorption Spectrophotometer LAAS-A13
  • 190 to 900 nmWorking spectral range
  • 0.1, 0.2, 0.4, 1.0 and 2.0 nmSpectral Bandwith
  • ± 0.15 nmWavelength accuracy
  • ≤ 0.04 nmWavelength repeatability

Single Beam UV/Visible Spectrophotometer

Labtron Single Beam UV/Visible Spectrophotometer feature a wide range of wavelengths and multiple options for spectral bandwidth selection. They facilitate quantitative analysis and photometric measurements through intuitive interfaces. They offer flexibility with various installed light sources. Our Single Beam UV/Vis Spectrophotometer ensure high performance by incorporating automatic wavelength adjustment.

Single Beam UV/Vis Spectrophotometer LUS-A52
  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Vis Spectrophotometer LUS-A51

  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Vis Spectrophotometer LUS-A50

  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Table Top Spectrophotometer

Labtron Table Top Spectrophotometer features ETC technology ensuring real-time calibration for precise results. They support multiple measurement apertures, including options for small, medium, and large sample sizes. They also have specialized configurations for liquids and reflective materials. Their high-capacity rechargeable batteries provide long-lasting performance. Our Table Top Spectrophotometer offer a wide range of color spaces and color difference formulas catering to diverse application needs.

Table Top Spectrophotometer LTS-A16
  • 360 nm to 780 nmWavelength Range
  • 10 nmWavelength Pitch
  • Silicon Photodiode ArraySensor
  • Concave GratingGrating Method
Table Top Spectrophotometer LTS-A15
  • 400 nm to 700 nmWavelength Range
  • 10 nmWavelength Interval
  • High sensitivity silicon photodiodeSensor
  • LEDLight Source

Table top spectrophotometer LTS-A10

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination system
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Dual light path sensor arraySensor

NIR Spectrophotometer

Labtron NIR Spectrophotometer feature a high-quality PTFE reference module and polystyrene wavelength standard filter for exceptional accuracy. Their automatic reference calibration and monitoring wavelengths ensure stable and reliable measurements. They support transmission measurement mode. Their grating monochromator optical system ensures minimal stray light and noise. Our NIR Spectrophotometer features a USB port for easy data transfer and operates efficiently within a wide temperature and humidity range.

NIR Spectrophotometer LNIR-A10

  • 900 nm to 2500 nmWavelength Range
  • ≤ 0.2Wavelength Accuracy
  • ≤ 0.05Wavelength Reproducibility
  • 8 nmBandwidth

Visible Spectrophotometer

Labtron Visible Spectrophotometer feature high-resolution grating systems that cover a broad wavelength range. These instruments offer multiple modes, including transmittance, absorbance, concentration, and autocalibration. They utilize adaptable light sources and silicon photodiode detectors for precise measurements. Our visible spectrophotometers provide exceptional stability and precision, making them ideal for industrial applications and research.

Vis Spectrophotometer LVS-A11
  • 335 ~ 1000 nmWavelength Range
  • 4 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • 1 nmWavelength Repeatability
Vis Spectrophotometer LVS-A10
  • 330 to 1000 nmWavelength Range
  • 5 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • ≤ 1.0 nmWavelength Repeatability

Vis Spectrophotometer LVS-B10

  • 325 ~ 1000 nmWavelength Range
  • AutomaticSetting Wavelength
  • 2 nmSpectral Bandwidth
  • ± 1.0 nmWavelength Accuracy