Vis Spectrophotometer LVS-B10

Visible spectrophotometer comes with large memory space which can store multiple sets of data. It comes with monolithic, microprocessor controlled LCD display of 128 × 64 bit. In this vis-spectrophotometer standard curve for quantitative measurement can be established in simple method. Quantitative measurement of standard curve is established through direct input of K & B factor. It is useful in scientific research and industries for detection of impurities and other elements.

  • Wavelength Range 325 ~ 1000 nm
    Setting Wavelength Automatic
    Spectral Bandwidth 2 nm
    Wavelength Accuracy ± 1.0 nm
    Wavelength Repeatability ≤ 0.2 nm
    Photometric Range (-0.3) ~ 3 A
    Photometric Mode
    Photometric Accuracy ± 0.3 % T
    Photometric Repeatability 0.15 % τ
    Transmittance accuracy
    Transmittance repeatability
    Detector Import Silicon Photodiode Detector
    Light Source Import Tungsten Lamp
    Stray Light ≤ 0.05 % τ
    Stability 0.001 A / h at 500 nm
    Data Output Port
    Power Requirement AC 220 V / 50 Hz, 110 V / 60 Hz.
    Dimensions 460 × 330 × 210 mm
    Noise
    Weight 11 kg
    Gross Weight
    Net Weight
    Power 120 W
    Display LCD
    Optical System
    Baseline Linearity
    Baseline Drift
    Baseline Flatness
    Printer Port
    Packing Size
    Software
    Packing Weight
    • Wavelength range of 325 ~ 1000 nm
    • Automatic zero, 100 % and wavelength adjustment
    • Equipped with Single-chip microcomputer control
    • Large LCD display with 128 × 64 bit
    • Large sample cell(~ 5 mm to 100 mm)
    • Colour filter automatic switching
    • More precise measurement
    • Imported Silicon Photodiode Detector and USB interface
  • It is useful in scientific research and industries for quantitative and qualitative analysis, detection of impurities and functional groups determination.

Related Products of Visible Spectrophotometer

Labtron Visible Spectrophotometer feature high-resolution grating systems that cover a broad wavelength range. These instruments offer multiple modes, including transmittance, absorbance, concentration, and autocalibration. They utilize adaptable light sources and silicon photodiode detectors for precise measurements. Our visible spectrophotometers provide exceptional stability and precision, making them ideal for industrial applications and research.

Visible Spectrophotometer LVS-A21

  • Single BeamPhotometry
  • Czerny-TurnerMonochromatic Type
  • 325 to 1000nmWavelength range
  • 2 nmSpectral bandwidth

Visible Spectrophotometer LVS-A20

  • Single BeamPhotometry
  • Czerny-TurnerMonochromatic Type
  • 340 to 1000nmWavelength range
  • 5 nmSpectral bandwidth

Vis Spectrophotometer LVS-C10

  • 320 ~ 1100 nmWavelength Range
  • 4 nmSpectral Bandwidth
  • ± 0.5 nmWavelength Accuracy
  • ≤ 0.2 nmWavelength Repeatability
Vis Spectrophotometer LVS-C11
  • 320 ~ 1000 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.5 nmWavelength Accuracy
  • ≤ 0.2 nmWavelength Repeatability
Vis Spectrophotometer LVS-A11
  • 335 ~ 1000 nmWavelength Range
  • 4 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • 1 nmWavelength Repeatability

Visible Spectrophotometer LVS-A30

  • 320 to 1100 nmWavelength range
  • 2.0 nmSpectral bandwidth
  • ± 0.8 nmWavelength Accuracy
  • ≤ 0.3 nmWavelength Repeatability

Vis Spectrophotometer LVS-A10

  • 330 to 1000 nmWavelength Range
  • 5 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • ≤ 1.0 nmWavelength Repeatability

Fluorescence Spectrophotometer

Labtron Fluorescence Spectrophotometer are built with sensitive signal detection technology and advanced optical systems. They offer impressive fluorescence detection limits and exceptional signal-to-noise ratios. With a dual beam ratio excitation light monitoring system, they ensure stable fluorescence signals. Our Fluorescence Spectrophotometer have built-in optical gates, which enable effective analysis of unstable samples.

Fluorescence Spectrophotometer LFS-A10

  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit

Fluorescence Spectrophotometer LFS-A12

  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit
Fluorescence Spectrophotometer LFS-A11
  • 150 W Xenon LampExcitation Source
  • 200 nm to 900 nmExcitation Wavelength
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmExcitation Slit
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmEmission Slit

Xenon Lamp Spectrophotometer

Labtron Xenon Lamp Spectrophotometer comes with a high-quality flashing Xenon lamp that requires no preheating and has a lifespan of 3 years. Their multiple work modes, including T, A, C, and E, offer exceptional flexibility for various types of measurements. They use imported silicon photodiode detectors for high sensitivity and stability. Our Xenon Lamp Spectrophotometer’s large sample chamber supports the attachment of optional accessories, enhancing adaptability.

Xenon Lamp Spectrophotometer LXLS-A13
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Xenon Lamp Spectrophotometer LXLS-A11

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 1 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Xenon Lamp Spectrophotometer LXLS-A10

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Portable Spectrophotometer

Labtron Portable Spectrophotometer utilize traditional whiteboards in their optical systems to ensure accurate measurements. They incorporate ETC technology for precise calibration. Include automated gloss compensating technology for accurate color measurements. Their extensive storage capacity provides long-term data retention. Our Portable Spectrophotometer are equipped with a TFT touch screen, a built-in camera, and high-capacity rechargeable batteries.

Portable spectrophotometer LSP-A10
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Blue light enhanced sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
Portable Spectrophotometer LSP-A31
  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • 60°Test angle

Portable Spectrophotometer LSP-A30

  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • -Test angle

NIR Spectrophotometer

Labtron NIR Spectrophotometer feature a high-quality PTFE reference module and polystyrene wavelength standard filter for exceptional accuracy. Their automatic reference calibration and monitoring wavelengths ensure stable and reliable measurements. They support transmission measurement mode. Their grating monochromator optical system ensures minimal stray light and noise. Our NIR Spectrophotometer features a USB port for easy data transfer and operates efficiently within a wide temperature and humidity range.

NIR Spectrophotometer LNIR-A10

  • 900 nm to 2500 nmWavelength Range
  • ≤ 0.2Wavelength Accuracy
  • ≤ 0.05Wavelength Reproducibility
  • 8 nmBandwidth

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer designed for accurate elemental analysis. Each of them features integrated flame and graphite furnace atomization systems, automatic wavelength scanning, and peak searching capabilities. Safety alarms ensure secure operation. Our Atomic Absorption Spectrophotometer delivers reliable results across a wide range of wavelengths with precise optics and temperature control.

Atomic Absorption Spectrophotometer LAAS-A20
  • 180 - 900 nmWavelength range
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability
Atomic Absorption Spectrophotometer LAAS-A11
  • 190 - 900 nmWavelength range
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nmSpectral Bandwidth
  • ≤ ± 0.5 nmWavelength accuracy
  • ≤ 0.3 nm(single direction)Wavelength repeatability

Atomic Absorption Spectrophotometer LAAS-A13

  • 190 to 900 nmWorking spectral range
  • 0.1, 0.2, 0.4, 1.0 and 2.0 nmSpectral Bandwith
  • ± 0.15 nmWavelength accuracy
  • ≤ 0.04 nmWavelength repeatability