Double Beam UV/Vis Spectrophotometer LUS-B31

Double Beam UV/Vis Spectrophotometer LUS-B31 is bench top device with 190 nm to 1100 nm wavelength range, and offers spectral bandwidth of 1 nm. With T, A, C, E work mode it is designed with Hi, Med, Low (Max. 3000 nm/min) scanning speed range. The latest ARM system and long optical system ensure high accuracy and good stability of the instrument. The 10.1 inch TFT Touch colored display and it can perform powerful functions like Photometric measurement, Quantitative measurement, Kinetics, Spectrum scan, DNA/Protein test, Multi-wavelength test etc. This advance, high quality spectrophotometer supports USB data transfer and storage system.

  • Wavelength range 190 to 1100 nm
    Spectral bandwidth 1 nm
    Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
    Wavelength Repeatability ≤ 0.1 nm
    Optical system Double beam 1200 lines/mm
    Photometric Range 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F)
    Photometric Accuracy 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F)
    Photometric Repeatability ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A)
    Detector Imported silicon photodiode
    Light source Imported Deuterium and Tungsten lamp
    Stray light ≤ 0.03 % T @ 220 nm, 360 nm
    Stability ± 0.0003 A/h @ 500 nm
    Data Output Port USB drive, USB host, RS232
    Power supply AC 220 V, 50 Hz or 110 V, 60 Hz
    Noise 0.0005 A @ 500 nm
    Display 10.1 inches TFT colored capacitive touch screen
    Baseline flatness ± 0.001 A
    Printer port Parallel port
    Work mode T, A, C, E
    Scanning speed Hi, Med, Low (Max. 3000 nm/min)
    Wavelength setting Auto
    Cuvette holder 10 mm single hole cell holder
    Dimension 810 × 660 × 390 mm
    Gross weight 27 kg
    • Work mode T, A, C, E and scanning speed range Hi, Med, Low (Max. 3000 nm/min)
    • Designed with double beam 1200 lines/mm optical system
    • In-house massive memory is capable of saving up to 1024 M for test data & working curves
    • Designed with 10.1 inches high resolution TFT colored capacitive touch screen and windows Graphic interface
    • Large sample chamber can accommodate 5 to 100 mm cuvettes of all kinds
    • Equipped with powerful functions like Photometric measurement, Quantitative measurement, Kinetics, Spectrum scan, DNA/Protein test, Multi-wavelength test, etc
    • The USB port can be used for data transfer, which can easily exported to excel for further processing
    • Socket type deuterium and tungsten lamp can make lamps switching without optics debugging and easy to be replaced
  • Double Beam UV/Vis Spectrophotometer is used in high requirement for precision measurement in the research and production of organic chemistry, biochemistry, medical testing, food testing, environmental protection, water testing industries, etc.

  • Accessories no. Name
    110 mm glass cuvette × 4
    210 mm quartz cuvette × 2
    32, power cord
    4User manual
    5PC software

Related Products of Double Beam UV/Vis Spectrophotometer

Labtron Double Beam UV/Vis Spectrophotometer offer automatic wavelength adjustments with their silicon photodiode detectors. Their dual beam designs cover a broad wavelength range. They support multiple measurement methods to meet diverse analytical requirements. Our spectrophotometer ensures precise results and ease of use with auto calibration, user-friendly interfaces, and advanced optics.

Double Beam UV-Vis Spectrophotometer LUS-B13

  • 190 to 1100 nmWavelength Range
  • 1.0 nmSpectral Bandwidth
  • Double beamOptical System
  • ±0.3 nmWavelength Accuracy

Double Beam UV-Vis Spectrophotometer LUS-B10

  • 190 to 1100 nmWavelength Range
  • 1.8 nmSpectral Bandwidth
  • Double beamOptical System
  • ±0.3 nmWavelength Accuracy

Double beam UV-Visible Spectrophotometer LUS-B15

  • 190 ~ 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • 0.5 nmWavelength accuracy
  • ≤ 0.2 nmWavelength repeatability
Double Beam UV/Vis Spectrophotometer LUS-B30
  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Double Beam UV/Vis Spectrophotometer LUS-B32
  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Double Beam UV-Vis Spectrophotometer LUS-B20

  • 190 to 1100 nmWavelength range
  • 1.0 to 5.0 nm (adjustable)Spectral bandwidth
  • Double beam, C-T monochromator, 1600 L/mm holographic gratingOptical system
  • ±0.3 nmWavelength accuracy

Double Beam UV-Vis Spectrophotometer LUS-B40

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4 nmSpectral bandwidth
  • ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full rangeWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Double Beam UV-Vis Spectrophotometer LUS-B12

  • 190 to 1100 nmWavelength Range
  • 1.8 nmSpectral Bandwidth
  • Split double beam, C-T monochromator,1200 L/mm holographic gratingOptical System
  • ±0.5nmWavelength Accuracy
Double Beam UV-Vis Spectrophotometer LUS-B11
  • 190 to 1100 nmWavelength range
  • 1.8 nmSpectral bandwidth
  • Double beam; 1200 lines/mm gratingOptical system
  • ±0.1nm (D2 656.1nm), ±0.3nm @ allWavelength accuracy
Double Beam UV/Vis Spectrophotometer LUS-B16
  • 190 ~ 1100 nmWavelength Range
  • AutomaticSetting Wavelength
  • 0.5 / 1.0 / 2.0 / 4.0 nm adjustableSpectral Bandwidth
  • ± 0.3 nmWavelength Accuracy

Single Beam UV/Visible Spectrophotometer

Labtron Single Beam UV/Visible Spectrophotometer feature a wide range of wavelengths and multiple options for spectral bandwidth selection. They facilitate quantitative analysis and photometric measurements through intuitive interfaces. They offer flexibility with various installed light sources. Our Single Beam UV/Vis Spectrophotometer ensure high performance by incorporating automatic wavelength adjustment.

Single Beam UV/Vis Spectrophotometer LUS-A51

  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Vis Spectrophotometer LUS-A52

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Single Beam UV/Vis Spectrophotometer LUS-A50
  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer designed for accurate elemental analysis. Each of them features integrated flame and graphite furnace atomization systems, automatic wavelength scanning, and peak searching capabilities. Safety alarms ensure secure operation. Our Atomic Absorption Spectrophotometer delivers reliable results across a wide range of wavelengths with precise optics and temperature control.

Atomic Absorption Spectrophotometer LAAS-A20
  • 180 - 900 nmWavelength range
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability

Atomic Absorption Spectrophotometer LAAS-A11

  • 190 - 900 nmWavelength range
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nmSpectral Bandwidth
  • ≤ ± 0.5 nmWavelength accuracy
  • ≤ 0.3 nm(single direction)Wavelength repeatability

Atomic Absorption Spectrophotometer LAAS-A13

  • 190 to 900 nmWorking spectral range
  • 0.1, 0.2, 0.4, 1.0 and 2.0 nmSpectral Bandwith
  • ± 0.15 nmWavelength accuracy
  • ≤ 0.04 nmWavelength repeatability

Nano Spectrophotometer

Labtron Nano Spectrophotometer enables rapid analysis of small sample volumes and features a wide wavelength range for precise measurements. They ensure high repeatability in detecting micro-volume quantities of nucleic acids and other components. They include built-in computers with USB connections and user-friendly interfaces. Our Nano Spectrophotometer are Ideal for concentrated samples without the need for dilution or baseline adjustments.

Nano Spectrophotometer LNS-A10
  • 200 - 800 nmWavelength range
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)Path length
  • ± 1 nmWavelength accuracy
  • ≤ 3 nm (FWHM at Hg 546 nm)Wavelength Resolution
Nano Spectrophotometer LNS-A21
  • 200 - 850 nmWavelength range
  • 1 mm, 2 mm, 5 mm, 10 mmPath length
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution

Nano Spectrophotometer LNS-B11

  • 230 nm, 260 nm, 280 nmWavelength range
  • 1.0 mm, 0.2 mmPath length
  • 0.3 - 2.0 µlMinimum Sample size
  • 0.2 - 75A (10 mm equivalent absorbance)Absorbance range

NIR Spectrophotometer

Labtron NIR Spectrophotometer feature a high-quality PTFE reference module and polystyrene wavelength standard filter for exceptional accuracy. Their automatic reference calibration and monitoring wavelengths ensure stable and reliable measurements. They support transmission measurement mode. Their grating monochromator optical system ensures minimal stray light and noise. Our NIR Spectrophotometer features a USB port for easy data transfer and operates efficiently within a wide temperature and humidity range.

NIR Spectrophotometer LNIR-A10

  • 900 nm to 2500 nmWavelength Range
  • ≤ 0.2Wavelength Accuracy
  • ≤ 0.05Wavelength Reproducibility
  • 8 nmBandwidth

Portable Spectrophotometer

Labtron Portable Spectrophotometer utilize traditional whiteboards in their optical systems to ensure accurate measurements. They incorporate ETC technology for precise calibration. Include automated gloss compensating technology for accurate color measurements. Their extensive storage capacity provides long-term data retention. Our Portable Spectrophotometer are equipped with a TFT touch screen, a built-in camera, and high-capacity rechargeable batteries.

Portable Spectrophotometer LSP-A30
  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • -Test angle
Portable spectrophotometer LSP-A10
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Blue light enhanced sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Portable Spectrophotometer LSP-A31

  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • 60°Test angle