Double Beam UV-Vis Spectrophotometer LUS-B11

Double Beam UV-Vis Spectrophotometer LUS-B11 is a compact, tabletop, wide screen double beam spectrophotometer comprising double beam long light path design, offers 190 to 1100 nm of wavelength range with 1200 L/mm grating. Features automatic calibration of all baseline, wavelength, and dark current, it has rigid 16 mm dicast aluminium base as optical mount. Equipped with 6 inches LCD display, standard software and USB interface, this spectrometer provides direct operation to multi functions and display the test results curve and data. With unique 520 mm long light path, it ensures great resolution with stability and reliability.

  • Wavelength range 190 to 1100 nm
    Spectral bandwidth 1.8 nm
    Optical system Double beam; 1200 lines/mm grating
    Wavelength accuracy ±0.1nm (D2 656.1nm), ±0.3nm @ all
    Wavelength repeatability 0.2 nm
    Photometric range -0.3 to 3 A; 0 to 200% T; 0 to 9999 C
    Photometric accuracy ±0.2% T (0 to 100% T)
    Photometric repeatability ≤0.1% T (0 to 100% T)
    Noise ± 0.0005 A/h
    Light source Tungsten lamp, Deuterium lamp
    Stray light ≤0.03% T @ 220 nm,360 nm
    Stability ± 0.001 A/h @ 500nm
    Display 320×240 Dots (6 inches) LCD display
    Baseline Flatness ±0.001A/h
    Detector Silicon photodiode
    Function Spectrum scanning, Standard curve, Kinetics, Multi wavelength scanning, DNA/Protein testing
    Interface USB
    Printer Parallel port
    PC software Yes
    Power supply AC 220 V/110 V,50/60 Hz
    Dimensions (W×D×H) 625×430×206 mm
    Weight 30 kg
    • Wide screen double beam spectrophotometer
    • Unique double beam 520 mm long light path design
    • 190 to 1100 nm of wavelength range with 1200 L/mm grating
    • Automatic calibration of all baseline, wavelength, and dark current
    • Rigid 16 mm dicast aluminium base as optical mount
    • 6 inches LCD display, standard software and USB interface
    • Direct operation to multi functions: spectrum scanning, standard curve, kinetics, multi wavelength scanning, DNA/Protein testing
    • Tungsten and deuterium lamp as light source
    • Great resolution with stability and reliability
  • Double Beam UV-Visible Spectrophotometer are used for analysis of band gap, optical coatings and thin films, quantitative analyses, kinetics, wavelength scanning, and DNA and Protein analysis across clinical and research laboratories.

Related Products of Double Beam UV/Vis Spectrophotometer

Labtron Double Beam UV/Vis Spectrophotometer offer automatic wavelength adjustments with their silicon photodiode detectors. Their dual beam designs cover a broad wavelength range. They support multiple measurement methods to meet diverse analytical requirements. Our spectrophotometer ensures precise results and ease of use with auto calibration, user-friendly interfaces, and advanced optics.

Double Beam UV/Vis Spectrophotometer LUS-B32

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Double beam UV-Visible Spectrophotometer LUS-B15

  • 190 ~ 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • 0.5 nmWavelength accuracy
  • ≤ 0.2 nmWavelength repeatability

Double Beam UV/Vis Spectrophotometer LUS-B30

  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Double Beam UV/Vis Spectrophotometer LUS-B16
  • 190 ~ 1100 nmWavelength Range
  • AutomaticSetting Wavelength
  • 0.5 / 1.0 / 2.0 / 4.0 nm adjustableSpectral Bandwidth
  • ± 0.3 nmWavelength Accuracy
Double Beam UV-Vis Spectrophotometer LUS-B13
  • 190 to 1100 nmWavelength Range
  • 1.0 nmSpectral Bandwidth
  • Double beamOptical System
  • ±0.3 nmWavelength Accuracy

Double Beam UV-Vis Spectrophotometer LUS-B10

  • 190 to 1100 nmWavelength Range
  • 1.8 nmSpectral Bandwidth
  • Double beamOptical System
  • ±0.3 nmWavelength Accuracy

Double Beam UV-Vis Spectrophotometer LUS-B12

  • 190 to 1100 nmWavelength Range
  • 1.8 nmSpectral Bandwidth
  • Split double beam, C-T monochromator,1200 L/mm holographic gratingOptical System
  • ±0.5nmWavelength Accuracy

Double Beam UV-Vis Spectrophotometer LUS-B20

  • 190 to 1100 nmWavelength range
  • 1.0 to 5.0 nm (adjustable)Spectral bandwidth
  • Double beam, C-T monochromator, 1600 L/mm holographic gratingOptical system
  • ±0.3 nmWavelength accuracy
Double Beam UV/Vis Spectrophotometer LUS-B31
  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Double Beam UV-Vis Spectrophotometer LUS-B40
  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4 nmSpectral bandwidth
  • ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full rangeWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

NIR Spectrophotometer

Labtron NIR Spectrophotometer feature a high-quality PTFE reference module and polystyrene wavelength standard filter for exceptional accuracy. Their automatic reference calibration and monitoring wavelengths ensure stable and reliable measurements. They support transmission measurement mode. Their grating monochromator optical system ensures minimal stray light and noise. Our NIR Spectrophotometer features a USB port for easy data transfer and operates efficiently within a wide temperature and humidity range.

NIR Spectrophotometer LNIR-A10

  • 900 nm to 2500 nmWavelength Range
  • ≤ 0.2Wavelength Accuracy
  • ≤ 0.05Wavelength Reproducibility
  • 8 nmBandwidth

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer designed for accurate elemental analysis. Each of them features integrated flame and graphite furnace atomization systems, automatic wavelength scanning, and peak searching capabilities. Safety alarms ensure secure operation. Our Atomic Absorption Spectrophotometer delivers reliable results across a wide range of wavelengths with precise optics and temperature control.

Atomic Absorption Spectrophotometer LAAS-A20

  • 180 - 900 nmWavelength range
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability
Atomic Absorption Spectrophotometer LAAS-A13
  • 190 to 900 nmWorking spectral range
  • 0.1, 0.2, 0.4, 1.0 and 2.0 nmSpectral Bandwith
  • ± 0.15 nmWavelength accuracy
  • ≤ 0.04 nmWavelength repeatability
Atomic Absorption Spectrophotometer LAAS-A11
  • 190 - 900 nmWavelength range
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nmSpectral Bandwidth
  • ≤ ± 0.5 nmWavelength accuracy
  • ≤ 0.3 nm(single direction)Wavelength repeatability

Nano Spectrophotometer

Labtron Nano Spectrophotometer enables rapid analysis of small sample volumes and features a wide wavelength range for precise measurements. They ensure high repeatability in detecting micro-volume quantities of nucleic acids and other components. They include built-in computers with USB connections and user-friendly interfaces. Our Nano Spectrophotometer are Ideal for concentrated samples without the need for dilution or baseline adjustments.

Nano Spectrophotometer LNS-A10

  • 200 - 800 nmWavelength range
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)Path length
  • ± 1 nmWavelength accuracy
  • ≤ 3 nm (FWHM at Hg 546 nm)Wavelength Resolution

Nano Spectrophotometer LNS-A21

  • 200 - 850 nmWavelength range
  • 1 mm, 2 mm, 5 mm, 10 mmPath length
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution
Nano Spectrophotometer LNS-B11
  • 230 nm, 260 nm, 280 nmWavelength range
  • 1.0 mm, 0.2 mmPath length
  • 0.3 - 2.0 µlMinimum Sample size
  • 0.2 - 75A (10 mm equivalent absorbance)Absorbance range

Fluorescence Spectrophotometer

Labtron Fluorescence Spectrophotometer are built with sensitive signal detection technology and advanced optical systems. They offer impressive fluorescence detection limits and exceptional signal-to-noise ratios. With a dual beam ratio excitation light monitoring system, they ensure stable fluorescence signals. Our Fluorescence Spectrophotometer have built-in optical gates, which enable effective analysis of unstable samples.

Fluorescence Spectrophotometer LFS-A10
  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit

Fluorescence Spectrophotometer LFS-A12

  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit

Fluorescence Spectrophotometer LFS-A11

  • 150 W Xenon LampExcitation Source
  • 200 nm to 900 nmExcitation Wavelength
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmExcitation Slit
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmEmission Slit

Visible Spectrophotometer

Labtron Visible Spectrophotometer feature high-resolution grating systems that cover a broad wavelength range. These instruments offer multiple modes, including transmittance, absorbance, concentration, and autocalibration. They utilize adaptable light sources and silicon photodiode detectors for precise measurements. Our visible spectrophotometers provide exceptional stability and precision, making them ideal for industrial applications and research.

Vis Spectrophotometer LVS-A10
  • 330 to 1000 nmWavelength Range
  • 5 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • ≤ 1.0 nmWavelength Repeatability
Vis Spectrophotometer LVS-A11
  • 335 ~ 1000 nmWavelength Range
  • 4 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • 1 nmWavelength Repeatability

Vis Spectrophotometer LVS-B10

  • 325 ~ 1000 nmWavelength Range
  • AutomaticSetting Wavelength
  • 2 nmSpectral Bandwidth
  • ± 1.0 nmWavelength Accuracy