Fluorescence Spectrophotometer LFS-A10

Fluorescence Spectrophotometer LFS-A10 consist of a high quality 150 W Xenon light source and photoelectric multiplier tube detectors for providing sufficient light intensity signal to detect sensitivity which ranges between 200 nm to 900 nm. Features fluorescence detection limit of ≤ 5×10-11 g/ml and Water Raman peak of S/N ≥ 200. It consists of the following characteristics, namely, high detection sensitivity, fast scanning speed, high dynamic range, fast 3D scanning, etc. The main principles includes measurement of absorption and fluorescence. Absorbance measurements can be taken via one or more wavelengths. The fluorescence unit increases the measuring range by 1000 for detecting DNA.

  • Light source 150 W Xenon lamp
    Excitation wavelength 200 nm to 900 nm
    Emission wavelength 200 nm to 900 nm
    Excitation slit 2 nm, 5 nm, 10 nm, 20 nm
    Emission slit 2 nm, 5 nm, 10 nm, 20 nm
    Wavelength accuracy ±0.4 nm
    Wavelength repeatability ≤ 0.2 nm
    Signal-to-Noise Ratio Raman peak of water (P-P): S/N ≥ 200 (10 nm Slit)
    Detection limit ≤5×10-11 g/ml (Quinine Sulphate Solution)
    Linearity γ ≥ 0.995
    Peak repeatability ≤ 1.5%
    Stability (10 min) Zero Drift ±0.3
    Stability (10 min) Value Limit ±1.5%
    Wavelength scan speed Multi-speed level, Maximum at 48000 nm/min
    Photometric value 0.00 to 10000.00
    Data interface USB 2.0
    Maximum power consumption 200 W
    Power Source AC 220 V/50 Hz; 110 V/60 Hz
    Dimension 380×445×310 mm
    Net weight 12 kg
    Gross weight 14 kg
    • High sensitivity is fetched from high efficiency optical design and weak signal detection technology
    • Excitation and emission wavelength range from 200 nm to 900 nm to meet most of the fluorescence analysis
    • Fluorescence detection limit of ≤ 5×10-11 g/ml and Water Raman peak of S/N ≥ 200
    • Classic fluorescence spectra and high quality 3D fluorescence spectra can be achieved via high scanning speed at 48000 nm/min
    • Wide Spectral measurement range is achieved using a double monochromator
    • Excitation light monitoring system consist of a light dual beam ratio to ensure the fluorescence signal is high and stable
    • Unstable samples is analysed via built-in optical gate
    • It is a highly advance structure with fine finishing
  • Fluorescence Spectrophotometer finds application in material research, pharmaceutical analysis, biochemical and clinical testing, water quality analysis and control, food safety testing.

  • Accessories No. Accessories Name Functions
    1 Membrane sample rack For membrane samples
    2 Powder sample rack For powder samples
    3 Up conversion fluorescent holder Base holder for other racks
    4 Octave Double-frequency elimination filter (300 nm,350 nm,400 nm,450 nm,500 nm,550 nm,600 nm,650 nm for one set) Remove the interference of double-frequency peaks of these wavelengths
    5 Auto polarization filter -
    6 Sample cell jacket -
    7 Peltier temperature (15 to 40°C) control holder -

Related Products of Fluorescence Spectrophotometer

Labtron Fluorescence Spectrophotometer are built with sensitive signal detection technology and advanced optical systems. They offer impressive fluorescence detection limits and exceptional signal-to-noise ratios. With a dual beam ratio excitation light monitoring system, they ensure stable fluorescence signals. Our Fluorescence Spectrophotometer have built-in optical gates, which enable effective analysis of unstable samples.

Fluorescence Spectrophotometer LFS-A11

  • 150 W Xenon LampExcitation Source
  • 200 nm to 900 nmExcitation Wavelength
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmExcitation Slit
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmEmission Slit

Fluorescence Spectrophotometer LFS-A12

  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit

Fluorescence Spectrophotometer

Labtron Fluorescence Spectrophotometer are built with sensitive signal detection technology and advanced optical systems. They offer impressive fluorescence detection limits and exceptional signal-to-noise ratios. With a dual beam ratio excitation light monitoring system, they ensure stable fluorescence signals. Our Fluorescence Spectrophotometer have built-in optical gates, which enable effective analysis of unstable samples.

Fluorescence Spectrophotometer LFS-A12

  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit

Fluorescence Spectrophotometer LFS-A11

  • 150 W Xenon LampExcitation Source
  • 200 nm to 900 nmExcitation Wavelength
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmExcitation Slit
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmEmission Slit
Fluorescence Spectrophotometer LFS-A10
  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit

Portable Spectrophotometer

Labtron Portable Spectrophotometer utilize traditional whiteboards in their optical systems to ensure accurate measurements. They incorporate ETC technology for precise calibration. Include automated gloss compensating technology for accurate color measurements. Their extensive storage capacity provides long-term data retention. Our Portable Spectrophotometer are equipped with a TFT touch screen, a built-in camera, and high-capacity rechargeable batteries.

Portable spectrophotometer LSP-A10
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Blue light enhanced sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Portable Spectrophotometer LSP-A31

  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • 60°Test angle

Portable Spectrophotometer LSP-A30

  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • -Test angle

Nano Spectrophotometer

Labtron Nano Spectrophotometer enables rapid analysis of small sample volumes and features a wide wavelength range for precise measurements. They ensure high repeatability in detecting micro-volume quantities of nucleic acids and other components. They include built-in computers with USB connections and user-friendly interfaces. Our Nano Spectrophotometer are Ideal for concentrated samples without the need for dilution or baseline adjustments.

Nano Spectrophotometer LNS-A21
  • 200 - 850 nmWavelength range
  • 1 mm, 2 mm, 5 mm, 10 mmPath length
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution
Nano Spectrophotometer LNS-A10
  • 200 - 800 nmWavelength range
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)Path length
  • ± 1 nmWavelength accuracy
  • ≤ 3 nm (FWHM at Hg 546 nm)Wavelength Resolution

Nano Spectrophotometer LNS-B11

  • 230 nm, 260 nm, 280 nmWavelength range
  • 1.0 mm, 0.2 mmPath length
  • 0.3 - 2.0 µlMinimum Sample size
  • 0.2 - 75A (10 mm equivalent absorbance)Absorbance range

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer designed for accurate elemental analysis. Each of them features integrated flame and graphite furnace atomization systems, automatic wavelength scanning, and peak searching capabilities. Safety alarms ensure secure operation. Our Atomic Absorption Spectrophotometer delivers reliable results across a wide range of wavelengths with precise optics and temperature control.

Atomic Absorption Spectrophotometer LAAS-A20

  • 180 - 900 nmWavelength range
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability
Atomic Absorption Spectrophotometer LAAS-A13
  • 190 to 900 nmWorking spectral range
  • 0.1, 0.2, 0.4, 1.0 and 2.0 nmSpectral Bandwith
  • ± 0.15 nmWavelength accuracy
  • ≤ 0.04 nmWavelength repeatability
Atomic Absorption Spectrophotometer LAAS-A11
  • 190 - 900 nmWavelength range
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nmSpectral Bandwidth
  • ≤ ± 0.5 nmWavelength accuracy
  • ≤ 0.3 nm(single direction)Wavelength repeatability

Table Top Spectrophotometer

Labtron Table Top Spectrophotometer features ETC technology ensuring real-time calibration for precise results. They support multiple measurement apertures, including options for small, medium, and large sample sizes. They also have specialized configurations for liquids and reflective materials. Their high-capacity rechargeable batteries provide long-lasting performance. Our Table Top Spectrophotometer offer a wide range of color spaces and color difference formulas catering to diverse application needs.

Table Top Spectrophotometer LTS-A16

  • 360 nm to 780 nmWavelength Range
  • 10 nmWavelength Pitch
  • Silicon Photodiode ArraySensor
  • Concave GratingGrating Method

Table Top Spectrophotometer LTS-A15

  • 400 nm to 700 nmWavelength Range
  • 10 nmWavelength Interval
  • High sensitivity silicon photodiodeSensor
  • LEDLight Source
Table top spectrophotometer LTS-A10
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination system
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Dual light path sensor arraySensor