Nano Spectrophotometer LNS-A10

Nano spectrophotometer with full spectrum light covers wide wavelength range of 200 to 800nm. It requires only 0.5 - 2.0 µl micro-volume sample for measurement which takes place within 5 seconds. It utilizes CCD detector, Xenon flash lamp as light source which has high stability and long operating life. They are used to detect micro volume quantities of nucleic acids and other concentrated or dilute components.

  • Cuvette
    Temperature
    PC
    Wavelength range 200 - 800 nm
    Path length 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
    Wavelength accuracy ± 1 nm
    Wavelength Resolution ≤ 3 nm (FWHM at Hg 546 nm)
    Path length of cuvette
    Minimum Sample size 0.5 - 2.0 µl
    Absorbance range 0.02 - 90 A (10mm equivalent)
    Precision of wavelength
    Absorbance precision 0.003 Abs
    Absorbance accuracy 1 % ( 7.332 Abs at 260 nm)
    Light source Xenon flash lamp
    Measurement time < 8 s
    Operating Voltage 24 V DC
    Sample Pedestal Material Aluminum alloy and Quartz fiber
    Detector Type 3864-element linear silicon CCD array
    Screen
    Software Compatibility Windows 7, Windows XP
    Detects nucleic acid up to 2 - 4500 ng/µL (dsDNA)
    Detects protein up to
    Data Output
    Operating Power Consumption 20 W
    Standby Power Consumption 5 W
    Dimension 200 x 250 x 166 mm
    Weight 2.6 kg
    • 0.5 µl - 2.0 µl micro-volume sample for direct measurement onto pedestal
    • Wavelength range 200 - 800 nm with scan capability within 5 seconds
    • User friendly software
    • Long life Xenon flash lamp (10 flashes up to 10 years)
    • Highly concentrated samples can be used
    • Direct Concentration display
    • No cell or cuvettes are required
  • Nano spectrophotometer are used in detection of micro volume quantities of DNA/RNA and chemicals , liquids and its components in laboratory, food industries, chemistry, microbiology, medicine research and development.

Related Products of Nano Spectrophotometer

Labtron Nano Spectrophotometer enables rapid analysis of small sample volumes and features a wide wavelength range for precise measurements. They ensure high repeatability in detecting micro-volume quantities of nucleic acids and other components. They include built-in computers with USB connections and user-friendly interfaces. Our Nano Spectrophotometer are Ideal for concentrated samples without the need for dilution or baseline adjustments.

Nano Spectrophotometer LNS-A20

  • 190 to 850 nmWavelength range
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution
  • Recyclable micro cuvette, 8.5 mm sample level heightCuvette details

Nano Spectrophotometer LNS-C13

  • YesCuvette
  • 4 ºC - 42 ºC (Heating & Cooling)Temperature
  • InbuiltPC
  • 190 - 850 nmWavelength range

Nano Spectrophotometer LNS-A21

  • 200 - 850 nmWavelength range
  • 1 mm, 2 mm, 5 mm, 10 mmPath length
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution
Nano Spectrophotometer LNS-C10
  • NoCuvette
  • InbuiltPC
  • 190 - 850 nmWavelength range
  • 1 mm, 0.2 mm ,0.04 mmPath length
Nano Spectrophotometer LNS-B10
  • 260 nm and 280 nm; FixedWavelength
  • ≤ 8 nmSpectral resolution
  • 0.5 mmPath length
  • 1 to 2 µlMinimum sample size

Nano Spectrophotometer LNS-B11

  • 230 nm, 260 nm, 280 nmWavelength range
  • 1.0 mm, 0.2 mmPath length
  • 0.3 - 2.0 µlMinimum Sample size
  • 0.2 - 75A (10 mm equivalent absorbance)Absorbance range

Nano Spectrophotometer LNS-C12

  • YesCuvette
  • Room Temperature 42 ºCTemperature
  • InbuiltPC
  • 190 - 850 nmWavelength range

Nano Spectrophotometer LNS-C11

  • YesCuvette
  • InbuiltPC
  • 190 - 850 nmWavelength range
  • 1 mm, 0.2 mm ,0.04 mmPath length

Table Top Spectrophotometer

Labtron Table Top Spectrophotometer features ETC technology ensuring real-time calibration for precise results. They support multiple measurement apertures, including options for small, medium, and large sample sizes. They also have specialized configurations for liquids and reflective materials. Their high-capacity rechargeable batteries provide long-lasting performance. Our Table Top Spectrophotometer offer a wide range of color spaces and color difference formulas catering to diverse application needs.

Table Top Spectrophotometer LTS-A15

  • 400 nm to 700 nmWavelength Range
  • 10 nmWavelength Interval
  • High sensitivity silicon photodiodeSensor
  • LEDLight Source

Table Top Spectrophotometer LTS-A16

  • 360 nm to 780 nmWavelength Range
  • 10 nmWavelength Pitch
  • Silicon Photodiode ArraySensor
  • Concave GratingGrating Method
Table top spectrophotometer LTS-A10
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination system
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Dual light path sensor arraySensor

Single Beam UV/Visible Spectrophotometer

Labtron Single Beam UV/Visible Spectrophotometer feature a wide range of wavelengths and multiple options for spectral bandwidth selection. They facilitate quantitative analysis and photometric measurements through intuitive interfaces. They offer flexibility with various installed light sources. Our Single Beam UV/Vis Spectrophotometer ensure high performance by incorporating automatic wavelength adjustment.

Single Beam UV/Vis Spectrophotometer LUS-A50
  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Vis Spectrophotometer LUS-A51

  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Vis Spectrophotometer LUS-A52

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Fluorescence Spectrophotometer

Labtron Fluorescence Spectrophotometer are built with sensitive signal detection technology and advanced optical systems. They offer impressive fluorescence detection limits and exceptional signal-to-noise ratios. With a dual beam ratio excitation light monitoring system, they ensure stable fluorescence signals. Our Fluorescence Spectrophotometer have built-in optical gates, which enable effective analysis of unstable samples.

Fluorescence Spectrophotometer LFS-A11
  • 150 W Xenon LampExcitation Source
  • 200 nm to 900 nmExcitation Wavelength
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmExcitation Slit
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmEmission Slit
Fluorescence Spectrophotometer LFS-A10
  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit

Fluorescence Spectrophotometer LFS-A12

  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit

Xenon Lamp Spectrophotometer

Labtron Xenon Lamp Spectrophotometer comes with a high-quality flashing Xenon lamp that requires no preheating and has a lifespan of 3 years. Their multiple work modes, including T, A, C, and E, offer exceptional flexibility for various types of measurements. They use imported silicon photodiode detectors for high sensitivity and stability. Our Xenon Lamp Spectrophotometer’s large sample chamber supports the attachment of optional accessories, enhancing adaptability.

Xenon Lamp Spectrophotometer LXLS-A13

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
Xenon Lamp Spectrophotometer LXLS-A11
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 1 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
Xenon Lamp Spectrophotometer LXLS-A10
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer designed for accurate elemental analysis. Each of them features integrated flame and graphite furnace atomization systems, automatic wavelength scanning, and peak searching capabilities. Safety alarms ensure secure operation. Our Atomic Absorption Spectrophotometer delivers reliable results across a wide range of wavelengths with precise optics and temperature control.

Atomic Absorption Spectrophotometer LAAS-A11

  • 190 - 900 nmWavelength range
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nmSpectral Bandwidth
  • ≤ ± 0.5 nmWavelength accuracy
  • ≤ 0.3 nm(single direction)Wavelength repeatability

Atomic Absorption Spectrophotometer LAAS-A20

  • 180 - 900 nmWavelength range
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability
Atomic Absorption Spectrophotometer LAAS-A13
  • 190 to 900 nmWorking spectral range
  • 0.1, 0.2, 0.4, 1.0 and 2.0 nmSpectral Bandwith
  • ± 0.15 nmWavelength accuracy
  • ≤ 0.04 nmWavelength repeatability