Nano Spectrophotometer LNS-C11

Nano Spectrophotometer with full spectrum covers a wide wavelength range of 190 to 850 nm. It requires only 0.3 - 2 µl sample for measurement which takes place within 5 seconds. It uses Xenon flash lamp as light source which has high stability and long operating life. It has built in Computer, screen & four USB interface. Nano spectrophotometer connected to mouse, printer, and other wireless card devices for multiple operations.

  • Cuvette Yes
    Temperature
    PC Inbuilt
    Wavelength range 190 - 850 nm
    Path length 1 mm, 0.2 mm ,0.04 mm
    Wavelength accuracy ± 1 nm
    Wavelength Resolution 2 nm (FWHM at Hg 546 nm)
    Path length of cuvette 1 mm/2 mm/5 mm/10 mm
    Minimum Sample size 0.3 - 2.0 µl
    Absorbance range 0 to 500 Abs
    Precision of wavelength ± 1 nm
    Absorbance precision 0.002 ~ 400 Abs (10 mm)
    Absorbance accuracy 1 % (0.76 absorbance at 350 nm)
    Light source Xenon flash lamp
    Measurement time < 5 s
    Operating Voltage
    Sample Pedestal Material Stainless steel and quartz fiber
    Detector Type 2048-element linear silicon CCD
    Screen Color LCD Touchscreen display
    Software Compatibility Win7 (64-bit operating system)/Win 8
    Detects nucleic acid up to 0.4 ~ 19000 ng/µL (dsDNA)
    Detects protein up to 0.01 ~ 400 mg/mL (BSA)
    Data Output
    Operating Power Consumption
    Standby Power Consumption
    Dimension 350 x 240 x 220 mm
    Weight 5.2 kg
    • Wavelength range 190 ~ 850 nm
    • Built in PC, screen & four USB interface
    • High accuracy and reproducibility
    • Highly concentrated samples can be used
    • Direct Concentration display
    • No need of dilutions and baseline corrections
    • Build in software
  • The nano spectrophotometer is used in laboratory, food industries, chemistry, microbiology, medicine research and development.

Related Products of Nano Spectrophotometer

Labtron Nano Spectrophotometer enables rapid analysis of small sample volumes and features a wide wavelength range for precise measurements. They ensure high repeatability in detecting micro-volume quantities of nucleic acids and other components. They include built-in computers with USB connections and user-friendly interfaces. Our Nano Spectrophotometer are Ideal for concentrated samples without the need for dilution or baseline adjustments.

Nano Spectrophotometer LNS-C13

  • YesCuvette
  • 4 ºC - 42 ºC (Heating & Cooling)Temperature
  • InbuiltPC
  • 190 - 850 nmWavelength range

Nano Spectrophotometer LNS-A20

  • 190 to 850 nmWavelength range
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution
  • Recyclable micro cuvette, 8.5 mm sample level heightCuvette details

Nano Spectrophotometer LNS-B10

  • 260 nm and 280 nm; FixedWavelength
  • ≤ 8 nmSpectral resolution
  • 0.5 mmPath length
  • 1 to 2 µlMinimum sample size
Nano Spectrophotometer LNS-A10
  • 200 - 800 nmWavelength range
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)Path length
  • ± 1 nmWavelength accuracy
  • ≤ 3 nm (FWHM at Hg 546 nm)Wavelength Resolution
Nano Spectrophotometer LNS-C10
  • NoCuvette
  • InbuiltPC
  • 190 - 850 nmWavelength range
  • 1 mm, 0.2 mm ,0.04 mmPath length

Nano Spectrophotometer LNS-A21

  • 200 - 850 nmWavelength range
  • 1 mm, 2 mm, 5 mm, 10 mmPath length
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution

Nano Spectrophotometer LNS-B11

  • 230 nm, 260 nm, 280 nmWavelength range
  • 1.0 mm, 0.2 mmPath length
  • 0.3 - 2.0 µlMinimum Sample size
  • 0.2 - 75A (10 mm equivalent absorbance)Absorbance range

Nano Spectrophotometer LNS-C12

  • YesCuvette
  • Room Temperature 42 ºCTemperature
  • InbuiltPC
  • 190 - 850 nmWavelength range

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer designed for accurate elemental analysis. Each of them features integrated flame and graphite furnace atomization systems, automatic wavelength scanning, and peak searching capabilities. Safety alarms ensure secure operation. Our Atomic Absorption Spectrophotometer delivers reliable results across a wide range of wavelengths with precise optics and temperature control.

Atomic Absorption Spectrophotometer LAAS-A11

  • 190 - 900 nmWavelength range
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nmSpectral Bandwidth
  • ≤ ± 0.5 nmWavelength accuracy
  • ≤ 0.3 nm(single direction)Wavelength repeatability

Atomic Absorption Spectrophotometer LAAS-A13

  • 190 to 900 nmWorking spectral range
  • 0.1, 0.2, 0.4, 1.0 and 2.0 nmSpectral Bandwith
  • ± 0.15 nmWavelength accuracy
  • ≤ 0.04 nmWavelength repeatability
Atomic Absorption Spectrophotometer LAAS-A20
  • 180 - 900 nmWavelength range
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability

Portable Spectrophotometer

Labtron Portable Spectrophotometer utilize traditional whiteboards in their optical systems to ensure accurate measurements. They incorporate ETC technology for precise calibration. Include automated gloss compensating technology for accurate color measurements. Their extensive storage capacity provides long-term data retention. Our Portable Spectrophotometer are equipped with a TFT touch screen, a built-in camera, and high-capacity rechargeable batteries.

Portable Spectrophotometer LSP-A31
  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • 60°Test angle

Portable Spectrophotometer LSP-A30

  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • -Test angle

Portable spectrophotometer LSP-A10

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Blue light enhanced sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Double Beam UV/Vis Spectrophotometer

Labtron Double Beam UV/Vis Spectrophotometer offer automatic wavelength adjustments with their silicon photodiode detectors. Their dual beam designs cover a broad wavelength range. They support multiple measurement methods to meet diverse analytical requirements. Our spectrophotometer ensures precise results and ease of use with auto calibration, user-friendly interfaces, and advanced optics.

Double Beam UV/Vis Spectrophotometer LUS-B31
  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Double Beam UV/Vis Spectrophotometer LUS-B32
  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Double Beam UV/Vis Spectrophotometer LUS-B30

  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Visible Spectrophotometer

Labtron Single Beam UV/Visible Spectrophotometer feature a wide range of wavelengths and multiple options for spectral bandwidth selection. They facilitate quantitative analysis and photometric measurements through intuitive interfaces. They offer flexibility with various installed light sources. Our Single Beam UV/Vis Spectrophotometer ensure high performance by incorporating automatic wavelength adjustment.

Single Beam UV/Vis Spectrophotometer LUS-A51

  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Single Beam UV/Vis Spectrophotometer LUS-A50
  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Single Beam UV/Vis Spectrophotometer LUS-A52
  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Xenon Lamp Spectrophotometer

Labtron Xenon Lamp Spectrophotometer comes with a high-quality flashing Xenon lamp that requires no preheating and has a lifespan of 3 years. Their multiple work modes, including T, A, C, and E, offer exceptional flexibility for various types of measurements. They use imported silicon photodiode detectors for high sensitivity and stability. Our Xenon Lamp Spectrophotometer’s large sample chamber supports the attachment of optional accessories, enhancing adaptability.

Xenon Lamp Spectrophotometer LXLS-A11

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 1 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Xenon Lamp Spectrophotometer LXLS-A13

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
Xenon Lamp Spectrophotometer LXLS-A10
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy