Nano Spectrophotometer LNS-C10

Nano Spectrophotometer with full spectrum covers a wide wavelength range of 190 to 850 nm. It requires only 0.3 - 2 µl sample for measurement which takes place within 5 seconds. It uses Xenon flash lamp as light source which has high stability and long operating life. It has built in Computer, screen & four USB interface. Nano spectrophotometer connected to mouse, printer, and other wireless card devices for multiple operations.

  • Cuvette No
    Temperature
    PC Inbuilt
    Wavelength range 190 - 850 nm
    Path length 1 mm, 0.2 mm ,0.04 mm
    Wavelength accuracy ± 1 nm
    Wavelength Resolution 2 nm (FWHM at Hg 546 nm)
    Path length of cuvette NA
    Minimum Sample size 0.3 - 2.0 µl
    Absorbance range 0 to 500 Abs
    Precision of wavelength ± 1 nm
    Absorbance precision 0.002 ~ 400 Abs (10 mm)
    Absorbance accuracy 1 % (0.76 absorbance at 350 nm)
    Light source Xenon flash lamp
    Measurement time < 5 s
    Operating Voltage
    Sample Pedestal Material Stainless steel and quartz fiber
    Detector Type 2048-element linear silicon CCD
    Screen Color LCD Touchscreen display
    Software Compatibility Win7 (64-bit operating system)/Win 8
    Detects nucleic acid up to 0.4 ~ 19000 ng/µL (dsDNA)
    Detects protein up to 0.01 ~ 400 mg/mL (BSA)
    Data Output
    Operating Power Consumption
    Standby Power Consumption
    Dimension 350 x 240 x 220 mm
    Weight 5.2 kg
    • Wavelength range 190 ~ 850 nm
    • Built in PC, screen & four USB interface
    • High accuracy and reproducibility
    • Highly concentrated samples can be used
    • Direct Concentration display
    • No need of dilutions and baseline corrections
    • Build in software
  • The nano spectrophotometer is used in laboratory, food industries, chemistry, microbiology, medicine research and development.

Related Products of Nano Spectrophotometer

Labtron Nano Spectrophotometer enables rapid analysis of small sample volumes and features a wide wavelength range for precise measurements. They ensure high repeatability in detecting micro-volume quantities of nucleic acids and other components. They include built-in computers with USB connections and user-friendly interfaces. Our Nano Spectrophotometer are Ideal for concentrated samples without the need for dilution or baseline adjustments.

Nano Spectrophotometer LNS-A21

  • 200 - 850 nmWavelength range
  • 1 mm, 2 mm, 5 mm, 10 mmPath length
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution

Nano Spectrophotometer LNS-A10

  • 200 - 800 nmWavelength range
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)Path length
  • ± 1 nmWavelength accuracy
  • ≤ 3 nm (FWHM at Hg 546 nm)Wavelength Resolution

Nano Spectrophotometer LNS-C12

  • YesCuvette
  • Room Temperature 42 ºCTemperature
  • InbuiltPC
  • 190 - 850 nmWavelength range
Nano Spectrophotometer LNS-B10
  • 260 nm and 280 nm; FixedWavelength
  • ≤ 8 nmSpectral resolution
  • 0.5 mmPath length
  • 1 to 2 µlMinimum sample size
Nano Spectrophotometer LNS-A20
  • 190 to 850 nmWavelength range
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution
  • Recyclable micro cuvette, 8.5 mm sample level heightCuvette details

Nano Spectrophotometer LNS-C11

  • YesCuvette
  • InbuiltPC
  • 190 - 850 nmWavelength range
  • 1 mm, 0.2 mm ,0.04 mmPath length

Nano Spectrophotometer LNS-C13

  • YesCuvette
  • 4 ºC - 42 ºC (Heating & Cooling)Temperature
  • InbuiltPC
  • 190 - 850 nmWavelength range

Nano Spectrophotometer LNS-B11

  • 230 nm, 260 nm, 280 nmWavelength range
  • 1.0 mm, 0.2 mmPath length
  • 0.3 - 2.0 µlMinimum Sample size
  • 0.2 - 75A (10 mm equivalent absorbance)Absorbance range

NIR Spectrophotometer

Labtron NIR Spectrophotometer feature a high-quality PTFE reference module and polystyrene wavelength standard filter for exceptional accuracy. Their automatic reference calibration and monitoring wavelengths ensure stable and reliable measurements. They support transmission measurement mode. Their grating monochromator optical system ensures minimal stray light and noise. Our NIR Spectrophotometer features a USB port for easy data transfer and operates efficiently within a wide temperature and humidity range.

NIR Spectrophotometer LNIR-A10

  • 900 nm to 2500 nmWavelength Range
  • ≤ 0.2Wavelength Accuracy
  • ≤ 0.05Wavelength Reproducibility
  • 8 nmBandwidth

Double Beam UV/Vis Spectrophotometer

Labtron Double Beam UV/Vis Spectrophotometer offer automatic wavelength adjustments with their silicon photodiode detectors. Their dual beam designs cover a broad wavelength range. They support multiple measurement methods to meet diverse analytical requirements. Our spectrophotometer ensures precise results and ease of use with auto calibration, user-friendly interfaces, and advanced optics.

Double Beam UV/Vis Spectrophotometer LUS-B32

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Double Beam UV/Vis Spectrophotometer LUS-B30
  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Double Beam UV/Vis Spectrophotometer LUS-B31
  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Table Top Spectrophotometer

Labtron Table Top Spectrophotometer features ETC technology ensuring real-time calibration for precise results. They support multiple measurement apertures, including options for small, medium, and large sample sizes. They also have specialized configurations for liquids and reflective materials. Their high-capacity rechargeable batteries provide long-lasting performance. Our Table Top Spectrophotometer offer a wide range of color spaces and color difference formulas catering to diverse application needs.

Table top spectrophotometer LTS-A10

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination system
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Dual light path sensor arraySensor

Table Top Spectrophotometer LTS-A15

  • 400 nm to 700 nmWavelength Range
  • 10 nmWavelength Interval
  • High sensitivity silicon photodiodeSensor
  • LEDLight Source
Table Top Spectrophotometer LTS-A16
  • 360 nm to 780 nmWavelength Range
  • 10 nmWavelength Pitch
  • Silicon Photodiode ArraySensor
  • Concave GratingGrating Method

Single Beam UV/Visible Spectrophotometer

Labtron Single Beam UV/Visible Spectrophotometer feature a wide range of wavelengths and multiple options for spectral bandwidth selection. They facilitate quantitative analysis and photometric measurements through intuitive interfaces. They offer flexibility with various installed light sources. Our Single Beam UV/Vis Spectrophotometer ensure high performance by incorporating automatic wavelength adjustment.

Single Beam UV/Vis Spectrophotometer LUS-A52
  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Vis Spectrophotometer LUS-A50

  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Vis Spectrophotometer LUS-A51

  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Fluorescence Spectrophotometer

Labtron Fluorescence Spectrophotometer are built with sensitive signal detection technology and advanced optical systems. They offer impressive fluorescence detection limits and exceptional signal-to-noise ratios. With a dual beam ratio excitation light monitoring system, they ensure stable fluorescence signals. Our Fluorescence Spectrophotometer have built-in optical gates, which enable effective analysis of unstable samples.

Fluorescence Spectrophotometer LFS-A12
  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit
Fluorescence Spectrophotometer LFS-A11
  • 150 W Xenon LampExcitation Source
  • 200 nm to 900 nmExcitation Wavelength
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmExcitation Slit
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmEmission Slit

Fluorescence Spectrophotometer LFS-A10

  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit