Portable Spectrophotometer LSP-A30

Portable Spectrophotometer LSP-A30 is adopted with 45/0 geometry (45 ring shaped illumination, 0 observe degree), where the standard white board is included in the optical system for great accuracy of every measurement. Large data storage space up to 20000 samples measurement records. The measurement of the color of the powder, granules and other materials can be done by adding the powder accessories to this spectrophotometer.

  • Illumination 45/0 (45 ring shaped illumination,0° observation angle)
    Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
    Sensor High sensitivity silicon photodiode
    Test angle -
    Test area -
    Test range -
    Test repeatability -
    Reproducibility -
    Inter instrument agreement 0.2 ΔE*ab (BCRA II color tiles, average test value of 12 tiles)
    Illumination light source LED
    Light source A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, NBF, TL83, TL184, NBF, U35
    Wavelength range 400 nm to 700 nm
    Wavelength interval 10 nm
    Observation angle 2°/10°
    Measuring aperture 11 mm
    Color space CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, Hunter-lab, Munsell MI, CMYK
    Color difference formula ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*94, ΔE*00, ΔEab(Hunter), 555 shade sort
    Other colorimetric indices WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint (ASTM E313,CIE,Ganz) Metamerism index Milm, Stick color fastness, Color fastness, ISO brightness, A density, T density, M density, E density.
    Color matching system Not included
    UV light source Not included
    Work temperature range 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation
    Battery capacity Rechargeable Lithium battery, 20000 continuous measurement tests, 7.4V/600 mAh
    Interface USB
    Data storage 20000 samples
    Display True color TFT touch screen
    Light source longevity 10 years, 3 million test
    Dimension 181 × 73 × 112 mm
    Weight 800 g (without battery)
    • 2.8 inch TFT touch screen
    • High capacity rechargeable lithium-ion battery
    • LED light source for measurement accuracy
    • Pre-locating panel design for instrument calibration
    • SCS system for measurement repeatability
    • Simultaneous measurement of SCI & SCE
    • USB & Bluetooth data transmission
    • Large storage capacity
    • Connection to mini printer for printing
  • Used in textile, plastic, food, paint, printing, automobile industries, laboratories & on-site applications for quality control purpose.

  • Accessories no. Accessories name Unit
    1 AC adapter 1
    2 Lithium battery 1
    3 Color QC software 1
    4 Driver software 1
    5 USB cable 1
    6 Calibration tile (black and white) 1
    7 Carrying bag 1

Related Products of Portable Spectrophotometer

Labtron Portable Spectrophotometer utilize traditional whiteboards in their optical systems to ensure accurate measurements. They incorporate ETC technology for precise calibration. Include automated gloss compensating technology for accurate color measurements. Their extensive storage capacity provides long-term data retention. Our Portable Spectrophotometer are equipped with a TFT touch screen, a built-in camera, and high-capacity rechargeable batteries.

Portable Spectrophotometer LSP-C11

  • 8º(diffused illumination, 8 degree viewing angle)Reflect
  • SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light sourceOptical Geometry
  • ISO7724-1, ASTM E1164, DIN5033 Teil7Standards
  • Φ 40 mmIntegrating Sphere Size

Portable spectrophotometer LSP-A11

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),br/> Maximum:0.03
    Repeatability
  • Dual light path sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Portable Spectrophotometer LSP-A31

  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • 60°Test angle
Portable Spectrophotometer LSP-C10
  • 8º(diffused illumination, 8 degree viewing angle)Reflect
  • SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light sourceOptical Geometry
  • ISO7724-1, ASTM E1164, DIN5033 Teil7Standards
  • Φ 40 mmIntegrating Sphere Size
Portable Spectrophotometer LSP-A40
  • D/8 (diffused illumination,8° viewing), Specular Component Included (SCI)Optical Geometry
  • Φ 40 mmIntegrating Sphere Size
  • LED (Full band balanced LED)Light Source
  • Reflectance, CIE-Lab, CIE-LCh, Hunter Lab, CIE Luv, XYZ, Yxy, RGB, Colour difference (ΔE × ab, ΔE × cmc, ΔE × 94, ΔE × 00), WI (ASTM E313-00, ASTM E313- 73, CIE/ISO, AATCC, Hunter, Taube Berger Stensby), YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Blackness (My,dM),Colour Fastness, Tint,(ASTM E313-00),Colour Density CMYK(A,T,E,M), Milm, Munsell, Opacity, Colour strengthColor Spaces and Indices

Portable spectrophotometer LSP-A13

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.02(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.04
    Repeatability
  • Photoelectric diode sensorSensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Portable spectrophotometer LSP-A20

  • Observation angles 2°/10°
    Illumination: d/8 (Diffused lighting, 8° observation angle)
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.04
    Repeatability
  • Dual light path sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Portable Spectrophotometer LSP-A41

  • D/8 (diffused illumination,8° viewing), SCI (Specular Component Included), SCE (Specular Component Excluded)Optical Geometry
  • Φ 40 mmIntegrating Sphere Size
  • LED (Full band balanced LED)Light Source
  • Reflectance, CIE-Lab, CIE-LCh, Hunter Lab, CIE Luv, XYZ, Yxy, RGB, Colour difference (ΔE × ab, ΔE × cmc, ΔE × 94, ΔE × 00), WI (ASTM E313-00, ASTM E313- 73, CIE/ISO, AATCC, Hunter, Taube Berger Stensby), YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Blackness (My,dM),Colour Fastness, Tint,(ASTM E313-00),Colour Density CMYK(A,T,E,M), Milm, Munsell, Opacity, Colour strengthColor Spaces and Indices
Portable spectrophotometer LSP-A10
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Blue light enhanced sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
Portable spectrophotometer LSP-A12
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Photoelectric diode sensorSensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Table Top Spectrophotometer

Labtron Table Top Spectrophotometer features ETC technology ensuring real-time calibration for precise results. They support multiple measurement apertures, including options for small, medium, and large sample sizes. They also have specialized configurations for liquids and reflective materials. Their high-capacity rechargeable batteries provide long-lasting performance. Our Table Top Spectrophotometer offer a wide range of color spaces and color difference formulas catering to diverse application needs.

Table Top Spectrophotometer LTS-A15

  • 400 nm to 700 nmWavelength Range
  • 10 nmWavelength Interval
  • High sensitivity silicon photodiodeSensor
  • LEDLight Source

Table top spectrophotometer LTS-A10

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination system
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Dual light path sensor arraySensor
Table Top Spectrophotometer LTS-A16
  • 360 nm to 780 nmWavelength Range
  • 10 nmWavelength Pitch
  • Silicon Photodiode ArraySensor
  • Concave GratingGrating Method

Portable Spectrophotometer

Labtron Portable Spectrophotometer utilize traditional whiteboards in their optical systems to ensure accurate measurements. They incorporate ETC technology for precise calibration. Include automated gloss compensating technology for accurate color measurements. Their extensive storage capacity provides long-term data retention. Our Portable Spectrophotometer are equipped with a TFT touch screen, a built-in camera, and high-capacity rechargeable batteries.

Portable Spectrophotometer LSP-A31
  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • 60°Test angle

Portable Spectrophotometer LSP-A30

  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • -Test angle

Portable spectrophotometer LSP-A10

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Blue light enhanced sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Visible Spectrophotometer

Labtron Visible Spectrophotometer feature high-resolution grating systems that cover a broad wavelength range. These instruments offer multiple modes, including transmittance, absorbance, concentration, and autocalibration. They utilize adaptable light sources and silicon photodiode detectors for precise measurements. Our visible spectrophotometers provide exceptional stability and precision, making them ideal for industrial applications and research.

Vis Spectrophotometer LVS-A10
  • 330 to 1000 nmWavelength Range
  • 5 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • ≤ 1.0 nmWavelength Repeatability
Vis Spectrophotometer LVS-B10
  • 325 ~ 1000 nmWavelength Range
  • AutomaticSetting Wavelength
  • 2 nmSpectral Bandwidth
  • ± 1.0 nmWavelength Accuracy

Vis Spectrophotometer LVS-A11

  • 335 ~ 1000 nmWavelength Range
  • 4 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • 1 nmWavelength Repeatability

Nano Spectrophotometer

Labtron Nano Spectrophotometer enables rapid analysis of small sample volumes and features a wide wavelength range for precise measurements. They ensure high repeatability in detecting micro-volume quantities of nucleic acids and other components. They include built-in computers with USB connections and user-friendly interfaces. Our Nano Spectrophotometer are Ideal for concentrated samples without the need for dilution or baseline adjustments.

Nano Spectrophotometer LNS-A10

  • 200 - 800 nmWavelength range
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)Path length
  • ± 1 nmWavelength accuracy
  • ≤ 3 nm (FWHM at Hg 546 nm)Wavelength Resolution
Nano Spectrophotometer LNS-A21
  • 200 - 850 nmWavelength range
  • 1 mm, 2 mm, 5 mm, 10 mmPath length
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution
Nano Spectrophotometer LNS-B11
  • 230 nm, 260 nm, 280 nmWavelength range
  • 1.0 mm, 0.2 mmPath length
  • 0.3 - 2.0 µlMinimum Sample size
  • 0.2 - 75A (10 mm equivalent absorbance)Absorbance range

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer designed for accurate elemental analysis. Each of them features integrated flame and graphite furnace atomization systems, automatic wavelength scanning, and peak searching capabilities. Safety alarms ensure secure operation. Our Atomic Absorption Spectrophotometer delivers reliable results across a wide range of wavelengths with precise optics and temperature control.

Atomic Absorption Spectrophotometer LAAS-A13

  • 190 to 900 nmWorking spectral range
  • 0.1, 0.2, 0.4, 1.0 and 2.0 nmSpectral Bandwith
  • ± 0.15 nmWavelength accuracy
  • ≤ 0.04 nmWavelength repeatability

Atomic Absorption Spectrophotometer LAAS-A20

  • 180 - 900 nmWavelength range
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability
Atomic Absorption Spectrophotometer LAAS-A11
  • 190 - 900 nmWavelength range
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nmSpectral Bandwidth
  • ≤ ± 0.5 nmWavelength accuracy
  • ≤ 0.3 nm(single direction)Wavelength repeatability