Portable Spectrophotometer LSP-C10

Portable Spectrophotometer LSP-C10 adopts 1000 line precision blazed grating as the spectroscopic element, the silicon photocell array with large photosensitive area as the detector. The full spectrum led with high life as the light source, and the optical resolution is less than 10 nm in the visible light range. Under the condition of d/8 geometric optical illumination recommended by CIE, spectrophotometer can accurately measure the SCI and SCE reflectance data of samples / fluorescent samples. It has stable performance, accurate color measurement and powerful function.

  • Reflect 8º(diffused illumination, 8 degree viewing angle)
    Optical Geometry SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source
    Standards ISO7724-1, ASTM E1164, DIN5033 Teil7
    Integrating Sphere Size Φ 40 mm
    Light Source Combined full spectrum LED light source, UV light source
    Spectrophotometric Mode Flat Grating
    Sensor Silicon photodiode array (double row 40 groups)
    Wavelength Range 400 to 700 nm
    Wavelength Interval 10 nm
    Semi band Width 10 nm
    Measured Reflectance Range 0 to 200%
    Measuring Aperture MAV Φ8 mm / Φ10 mm SAV Φ4 mm / Φ5 mm
    Specular Component SCI & SCE
    Color Space CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, HunterLab, βxy,DIN Lab99 Munsell (C/2)
    Color Difference Formula ΔE×ab, ΔE×uv, ΔE×94, ΔE×cmc(2:1), ΔE×cmc(1:1), ΔE×00, DINΔE99, ΔE (Hunter)
    Other Colorimetric Index WI (ASTM E313,CIE/ISO, AATCC, Hunter), YI(ASTM D1925, ASTM 313), Metamerism Index MI, Staining Fastness, Color Fastness, Color Strength, Opacity, 8° Glossiness, 555 tone classification
    Illuminant D65, A , C, D50, D55, D75, F1, F2(CWF), F3, F4, F5, F6, F7(DLF), F8, F9, F10(TPL5), F11(TL84), F12(TL83/U30)
    Observer Angle 2° / 10°
    Measuring Time About 1.5 s (Measure SCI & SCE about 3.2 s)
    Repeatability Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%) Chromaticity value: MAV/SCI, within ΔE × ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
    Inter-instrument Error MAV/SCI, Within ΔE×ab0.15 (Average for 12 BCRA Series II color tiles)
    Measurement Mode Single Measurement, Average Measurement(2 to 99 times)
    Locating Method Camera Locating, stabilizer cross position
    Displayed Data 3.5 inch TFT color LCD, Capacitive Touch Screen
    Data Port USB, Bluetooth 4.2
    Data Storage Standard 1000 Pcs, Sample 30000 Pcs
    Language English
    Operating temperature 0 to 40ºC
    Operating humidity 0 to 85 %RH
    Dimension 129 × 76 × 217 mm
    Battery Li-ion battery, 6000 measurements within 8 hours
    Weight Approx. 600 g
    • Designed with combined LED light source with high life and low power consumption, including UV / excluding UV
    • Dual optical path system, the optical resolution in the visible range is less than 10 nm
    • It measures the SCI and SCE spectrum of the sample at the same time
    • Accurate spectrum and lab data, used for color matching and accurate color transmission
    • USB / Bluetooth dual communication mode, wider adaptability
    • Large capacity storage space, which can store more than 30000 pieces of test data
    • Camera locating position and Stabilizer cross measurement position
    • PC software has powerful function expansion
  • Portable Spectrophotometer is used in plastic electronics, paint and coating, textile printing and dyeing, printing paper, automobile, medical treatment, cosmetics and food industries, as well as scientific research institutions and laboratories etc.

  • Accessories no.Name
    1Power Adapter
    2User Guide
    3PC Software
    4USB cable
    5White and Black Calibration Cavity
    6Protective Cover
    7Wrist strap
    88 mm flat aperture
    98 mm tip aperture
    104 mm flat aperture
    114 mm tip aperture

Related Products of Portable Spectrophotometer

Labtron Portable Spectrophotometer utilize traditional whiteboards in their optical systems to ensure accurate measurements. They incorporate ETC technology for precise calibration. Include automated gloss compensating technology for accurate color measurements. Their extensive storage capacity provides long-term data retention. Our Portable Spectrophotometer are equipped with a TFT touch screen, a built-in camera, and high-capacity rechargeable batteries.

Portable spectrophotometer LSP-A20

  • Observation angles 2°/10°
    Illumination: d/8 (Diffused lighting, 8° observation angle)
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.04
    Repeatability
  • Dual light path sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Portable Spectrophotometer LSP-A41

  • D/8 (diffused illumination,8° viewing), SCI (Specular Component Included), SCE (Specular Component Excluded)Optical Geometry
  • Φ 40 mmIntegrating Sphere Size
  • LED (Full band balanced LED)Light Source
  • Reflectance, CIE-Lab, CIE-LCh, Hunter Lab, CIE Luv, XYZ, Yxy, RGB, Colour difference (ΔE × ab, ΔE × cmc, ΔE × 94, ΔE × 00), WI (ASTM E313-00, ASTM E313- 73, CIE/ISO, AATCC, Hunter, Taube Berger Stensby), YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Blackness (My,dM),Colour Fastness, Tint,(ASTM E313-00),Colour Density CMYK(A,T,E,M), Milm, Munsell, Opacity, Colour strengthColor Spaces and Indices

Portable spectrophotometer LSP-A10

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Blue light enhanced sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
Portable Spectrophotometer LSP-A40
  • D/8 (diffused illumination,8° viewing), Specular Component Included (SCI)Optical Geometry
  • Φ 40 mmIntegrating Sphere Size
  • LED (Full band balanced LED)Light Source
  • Reflectance, CIE-Lab, CIE-LCh, Hunter Lab, CIE Luv, XYZ, Yxy, RGB, Colour difference (ΔE × ab, ΔE × cmc, ΔE × 94, ΔE × 00), WI (ASTM E313-00, ASTM E313- 73, CIE/ISO, AATCC, Hunter, Taube Berger Stensby), YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Blackness (My,dM),Colour Fastness, Tint,(ASTM E313-00),Colour Density CMYK(A,T,E,M), Milm, Munsell, Opacity, Colour strengthColor Spaces and Indices
Portable spectrophotometer LSP-A11
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),br/> Maximum:0.03
    Repeatability
  • Dual light path sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Portable spectrophotometer LSP-A13

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.02(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.04
    Repeatability
  • Photoelectric diode sensorSensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Portable Spectrophotometer LSP-A31

  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • 60°Test angle

Portable Spectrophotometer LSP-C11

  • 8º(diffused illumination, 8 degree viewing angle)Reflect
  • SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light sourceOptical Geometry
  • ISO7724-1, ASTM E1164, DIN5033 Teil7Standards
  • Φ 40 mmIntegrating Sphere Size
Portable Spectrophotometer LSP-A30
  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • -Test angle
Portable spectrophotometer LSP-A12
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Photoelectric diode sensorSensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Nano Spectrophotometer

Labtron Nano Spectrophotometer enables rapid analysis of small sample volumes and features a wide wavelength range for precise measurements. They ensure high repeatability in detecting micro-volume quantities of nucleic acids and other components. They include built-in computers with USB connections and user-friendly interfaces. Our Nano Spectrophotometer are Ideal for concentrated samples without the need for dilution or baseline adjustments.

Nano Spectrophotometer LNS-B11

  • 230 nm, 260 nm, 280 nmWavelength range
  • 1.0 mm, 0.2 mmPath length
  • 0.3 - 2.0 µlMinimum Sample size
  • 0.2 - 75A (10 mm equivalent absorbance)Absorbance range

Nano Spectrophotometer LNS-A10

  • 200 - 800 nmWavelength range
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)Path length
  • ± 1 nmWavelength accuracy
  • ≤ 3 nm (FWHM at Hg 546 nm)Wavelength Resolution
Nano Spectrophotometer LNS-A21
  • 200 - 850 nmWavelength range
  • 1 mm, 2 mm, 5 mm, 10 mmPath length
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer designed for accurate elemental analysis. Each of them features integrated flame and graphite furnace atomization systems, automatic wavelength scanning, and peak searching capabilities. Safety alarms ensure secure operation. Our Atomic Absorption Spectrophotometer delivers reliable results across a wide range of wavelengths with precise optics and temperature control.

Atomic Absorption Spectrophotometer LAAS-A11
  • 190 - 900 nmWavelength range
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nmSpectral Bandwidth
  • ≤ ± 0.5 nmWavelength accuracy
  • ≤ 0.3 nm(single direction)Wavelength repeatability

Atomic Absorption Spectrophotometer LAAS-A20

  • 180 - 900 nmWavelength range
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability

Atomic Absorption Spectrophotometer LAAS-A13

  • 190 to 900 nmWorking spectral range
  • 0.1, 0.2, 0.4, 1.0 and 2.0 nmSpectral Bandwith
  • ± 0.15 nmWavelength accuracy
  • ≤ 0.04 nmWavelength repeatability

Double Beam UV/Vis Spectrophotometer

Labtron Double Beam UV/Vis Spectrophotometer offer automatic wavelength adjustments with their silicon photodiode detectors. Their dual beam designs cover a broad wavelength range. They support multiple measurement methods to meet diverse analytical requirements. Our spectrophotometer ensures precise results and ease of use with auto calibration, user-friendly interfaces, and advanced optics.

Double Beam UV/Vis Spectrophotometer LUS-B30
  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Double Beam UV/Vis Spectrophotometer LUS-B31
  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Double Beam UV/Vis Spectrophotometer LUS-B32

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Visible Spectrophotometer

Labtron Visible Spectrophotometer feature high-resolution grating systems that cover a broad wavelength range. These instruments offer multiple modes, including transmittance, absorbance, concentration, and autocalibration. They utilize adaptable light sources and silicon photodiode detectors for precise measurements. Our visible spectrophotometers provide exceptional stability and precision, making them ideal for industrial applications and research.

Vis Spectrophotometer LVS-A10

  • 330 to 1000 nmWavelength Range
  • 5 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • ≤ 1.0 nmWavelength Repeatability
Vis Spectrophotometer LVS-B10
  • 325 ~ 1000 nmWavelength Range
  • AutomaticSetting Wavelength
  • 2 nmSpectral Bandwidth
  • ± 1.0 nmWavelength Accuracy
Vis Spectrophotometer LVS-A11
  • 335 ~ 1000 nmWavelength Range
  • 4 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • 1 nmWavelength Repeatability

Single Beam UV/Visible Spectrophotometer

Labtron Single Beam UV/Visible Spectrophotometer feature a wide range of wavelengths and multiple options for spectral bandwidth selection. They facilitate quantitative analysis and photometric measurements through intuitive interfaces. They offer flexibility with various installed light sources. Our Single Beam UV/Vis Spectrophotometer ensure high performance by incorporating automatic wavelength adjustment.

Single Beam UV/Vis Spectrophotometer LUS-A51

  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Vis Spectrophotometer LUS-A52

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Single Beam UV/Vis Spectrophotometer LUS-A50
  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability