Vis Spectrophotometer LVS-A10

Visible spectrophotometer LVS-A10 offers 330 to 1000 nm wavelength range with single beam has 1200 lines/mm grating C-T monochromator optical system. It uses silicon photo diode detector and tungsten lamp as light source which provides the best wavelength coverage across the working range of the spectrophotometer. The Display screen show the concentration data. This highly accurate spectrophotometer is designed for industries and laboratories.

  • Wavelength Range 330 to 1000 nm
    Setting Wavelength
    Spectral Bandwidth 5 nm
    Wavelength Accuracy ± 2 nm
    Wavelength Repeatability ≤ 1.0 nm
    Photometric Range T: 0 to199.9%, A: -0.3 to2.5 Abs, F; 0 to 9999, C: 0 to 9999
    Photometric Mode
    Photometric Accuracy ± 0.5 % T
    Photometric Repeatability ≤ 0.2 % T
    Transmittance accuracy
    Transmittance repeatability
    Detector Silicone photo diode
    Light Source 20 W, 12 V Tungsten lamp
    Stray Light ≤ 0.5 % T (360 nm)
    Stability Dark current: ≤ 0.2 % T, Light Current: ≤ 0.5 % T
    Data Output Port
    Power Requirement 220 V ± 20 V, 50 Hz ± 1 Hz
    Dimensions 470 × 350 × 200 mm
    Noise
    Weight 8 kg
    Gross Weight
    Net Weight
    Power
    Display LCD
    Optical System Single beam, C-T grating monochromator 1200 lines/ mm
    Baseline Linearity
    Baseline Drift
    Baseline Flatness
    Printer Port
    Packing Size
    Software
    Packing Weight
    • Wavelength range 330 to 1000 nm
    • Spectral bandwidth 5 nm
    • C-T grating monochromator 1200 lines/ mm
    • 20 W, 12 V Tungsten lamp as light source
    • 100 % Transmittance calibration
    • High accuracy with digital wavelength display
  • Visible spectrophotometer is used for quantitative and qualitative analysis, detection of impurities and functional groups determination etc. across biochemical, environmental, food, medical, petrochemical and other industry.

Related Products of Visible Spectrophotometer

Labtron Visible Spectrophotometer feature high-resolution grating systems that cover a broad wavelength range. These instruments offer multiple modes, including transmittance, absorbance, concentration, and autocalibration. They utilize adaptable light sources and silicon photodiode detectors for precise measurements. Our visible spectrophotometers provide exceptional stability and precision, making them ideal for industrial applications and research.

Vis Spectrophotometer LVS-C10

  • 320 ~ 1100 nmWavelength Range
  • 4 nmSpectral Bandwidth
  • ± 0.5 nmWavelength Accuracy
  • ≤ 0.2 nmWavelength Repeatability

Vis Spectrophotometer LVS-C11

  • 320 ~ 1000 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.5 nmWavelength Accuracy
  • ≤ 0.2 nmWavelength Repeatability

Visible Spectrophotometer LVS-A30

  • 320 to 1100 nmWavelength range
  • 2.0 nmSpectral bandwidth
  • ± 0.8 nmWavelength Accuracy
  • ≤ 0.3 nmWavelength Repeatability
Visible Spectrophotometer LVS-A21
  • Single BeamPhotometry
  • Czerny-TurnerMonochromatic Type
  • 325 to 1000nmWavelength range
  • 2 nmSpectral bandwidth
Visible Spectrophotometer LVS-A20
  • Single BeamPhotometry
  • Czerny-TurnerMonochromatic Type
  • 340 to 1000nmWavelength range
  • 5 nmSpectral bandwidth

Vis Spectrophotometer LVS-B10

  • 325 ~ 1000 nmWavelength Range
  • AutomaticSetting Wavelength
  • 2 nmSpectral Bandwidth
  • ± 1.0 nmWavelength Accuracy

Vis Spectrophotometer LVS-A11

  • 335 ~ 1000 nmWavelength Range
  • 4 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • 1 nmWavelength Repeatability

Visible Spectrophotometer

Labtron Visible Spectrophotometer feature high-resolution grating systems that cover a broad wavelength range. These instruments offer multiple modes, including transmittance, absorbance, concentration, and autocalibration. They utilize adaptable light sources and silicon photodiode detectors for precise measurements. Our visible spectrophotometers provide exceptional stability and precision, making them ideal for industrial applications and research.

Vis Spectrophotometer LVS-B10

  • 325 ~ 1000 nmWavelength Range
  • AutomaticSetting Wavelength
  • 2 nmSpectral Bandwidth
  • ± 1.0 nmWavelength Accuracy

Vis Spectrophotometer LVS-A11

  • 335 ~ 1000 nmWavelength Range
  • 4 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • 1 nmWavelength Repeatability
Vis Spectrophotometer LVS-A10
  • 330 to 1000 nmWavelength Range
  • 5 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • ≤ 1.0 nmWavelength Repeatability

Fluorescence Spectrophotometer

Labtron Fluorescence Spectrophotometer are built with sensitive signal detection technology and advanced optical systems. They offer impressive fluorescence detection limits and exceptional signal-to-noise ratios. With a dual beam ratio excitation light monitoring system, they ensure stable fluorescence signals. Our Fluorescence Spectrophotometer have built-in optical gates, which enable effective analysis of unstable samples.

Fluorescence Spectrophotometer LFS-A10
  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit

Fluorescence Spectrophotometer LFS-A12

  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit

Fluorescence Spectrophotometer LFS-A11

  • 150 W Xenon LampExcitation Source
  • 200 nm to 900 nmExcitation Wavelength
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmExcitation Slit
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmEmission Slit

Xenon Lamp Spectrophotometer

Labtron Xenon Lamp Spectrophotometer comes with a high-quality flashing Xenon lamp that requires no preheating and has a lifespan of 3 years. Their multiple work modes, including T, A, C, and E, offer exceptional flexibility for various types of measurements. They use imported silicon photodiode detectors for high sensitivity and stability. Our Xenon Lamp Spectrophotometer’s large sample chamber supports the attachment of optional accessories, enhancing adaptability.

Xenon Lamp Spectrophotometer LXLS-A10
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
Xenon Lamp Spectrophotometer LXLS-A11
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 1 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Xenon Lamp Spectrophotometer LXLS-A13

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Double Beam UV/Vis Spectrophotometer

Labtron Double Beam UV/Vis Spectrophotometer offer automatic wavelength adjustments with their silicon photodiode detectors. Their dual beam designs cover a broad wavelength range. They support multiple measurement methods to meet diverse analytical requirements. Our spectrophotometer ensures precise results and ease of use with auto calibration, user-friendly interfaces, and advanced optics.

Double Beam UV/Vis Spectrophotometer LUS-B32

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Double Beam UV/Vis Spectrophotometer LUS-B31
  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Double Beam UV/Vis Spectrophotometer LUS-B30
  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Portable Spectrophotometer

Labtron Portable Spectrophotometer utilize traditional whiteboards in their optical systems to ensure accurate measurements. They incorporate ETC technology for precise calibration. Include automated gloss compensating technology for accurate color measurements. Their extensive storage capacity provides long-term data retention. Our Portable Spectrophotometer are equipped with a TFT touch screen, a built-in camera, and high-capacity rechargeable batteries.

Portable Spectrophotometer LSP-A30

  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • -Test angle

Portable spectrophotometer LSP-A10

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Blue light enhanced sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
Portable Spectrophotometer LSP-A31
  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • 60°Test angle