Visible Spectrophotometer LVS-A20 is single beam bench top device with 340 to 1000 nm wavelength range, and offers spectral bandwidth of 5 nm. Features with T, A, C photometric working mode and Czerny-Turner monochromator type unit. Designed with holographic blazed grating monochromator it has the advantage of high wavelength accuracy, good monochromaticity and low stray light. The high accuracy and good reproducibility and stability of measurement reading instrument.

  • Photometry Single Beam
    Monochromatic Type Czerny-Turner
    Wavelength range 340 to 1000nm
    Spectral bandwidth 5 nm
    Wavelength Accuracy ± 2nm
    Wavelength Repeatability ≤ 1 nm
    Focal length 160 mm
    Photometric Range 0 to 100.0 %T 0 to 1.999 A 0 to 1999 C
    Photometric Accuracy ± 0.5 % T
    Photometric Repeatability ≤ 0.2 % T
    Detector Silicon Photocell
    Grating 1200 lines/mm
    Stray light ≤ 0.1( at 360nm NaNo2 )
    Noise 100%(T)noise≤0.3%(T) , 0%(T) noise ≤0.2 %(T)
    Cuvette holder size 10 mm
    Dimension 580 × 460 × 345 mm
    Power consumption 80 W
    Power supply AC 220 V±22 V 50Hz ±1 Hz
    Gross weight 12.5 kg
    • The holographic blazed grating monochromator has the advantages of high wavelength accuracy, good monochromaticity and low stray light
    • Sample compartment for 5 to 50 mm cuvettes
    • Equipped with USB port and automatic zero, full scale adjustment
    • Automatic light gate technology to protect photoelectric sensors
    • Adopts microprocessor control technology, qualitative analysis of substances in the visible spectrum, High accuracy of measurement readings, good stability
    • Automatic light gate technology, no need blackbody, to protect the photoelectric sensor
  • Visible Spectrophotometer is used in high requirement for precision measurement in the research and production of organic chemistry, biochemistry, medical testing, food testing, environmental protection, water testing industries, etc.

  • Accessories no.Name Qty.
    1User manual1 pc
    2Glass cuvette 1cm 44 pcs
    4Power cable1 pc
    5Fuse2 pcs

Related Products of Visible Spectrophotometer

Labtron Visible Spectrophotometer feature high-resolution grating systems that cover a broad wavelength range. These instruments offer multiple modes, including transmittance, absorbance, concentration, and autocalibration. They utilize adaptable light sources and silicon photodiode detectors for precise measurements. Our visible spectrophotometers provide exceptional stability and precision, making them ideal for industrial applications and research.

Vis Spectrophotometer LVS-B10

  • 325 ~ 1000 nmWavelength Range
  • AutomaticSetting Wavelength
  • 2 nmSpectral Bandwidth
  • ± 1.0 nmWavelength Accuracy

Vis Spectrophotometer LVS-A11

  • 335 ~ 1000 nmWavelength Range
  • 4 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • 1 nmWavelength Repeatability

Visible Spectrophotometer LVS-A30

  • 320 to 1100 nmWavelength range
  • 2.0 nmSpectral bandwidth
  • ± 0.8 nmWavelength Accuracy
  • ≤ 0.3 nmWavelength Repeatability
Vis Spectrophotometer LVS-C11
  • 320 ~ 1000 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.5 nmWavelength Accuracy
  • ≤ 0.2 nmWavelength Repeatability
Visible Spectrophotometer LVS-A21
  • Single BeamPhotometry
  • Czerny-TurnerMonochromatic Type
  • 325 to 1000nmWavelength range
  • 2 nmSpectral bandwidth

Vis Spectrophotometer LVS-C10

  • 320 ~ 1100 nmWavelength Range
  • 4 nmSpectral Bandwidth
  • ± 0.5 nmWavelength Accuracy
  • ≤ 0.2 nmWavelength Repeatability

Vis Spectrophotometer LVS-A10

  • 330 to 1000 nmWavelength Range
  • 5 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • ≤ 1.0 nmWavelength Repeatability

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer designed for accurate elemental analysis. Each of them features integrated flame and graphite furnace atomization systems, automatic wavelength scanning, and peak searching capabilities. Safety alarms ensure secure operation. Our Atomic Absorption Spectrophotometer delivers reliable results across a wide range of wavelengths with precise optics and temperature control.

Atomic Absorption Spectrophotometer LAAS-A11

  • 190 - 900 nmWavelength range
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nmSpectral Bandwidth
  • ≤ ± 0.5 nmWavelength accuracy
  • ≤ 0.3 nm(single direction)Wavelength repeatability

Atomic Absorption Spectrophotometer LAAS-A20

  • 180 - 900 nmWavelength range
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability
Atomic Absorption Spectrophotometer LAAS-A13
  • 190 to 900 nmWorking spectral range
  • 0.1, 0.2, 0.4, 1.0 and 2.0 nmSpectral Bandwith
  • ± 0.15 nmWavelength accuracy
  • ≤ 0.04 nmWavelength repeatability

Portable Spectrophotometer

Labtron Portable Spectrophotometer utilize traditional whiteboards in their optical systems to ensure accurate measurements. They incorporate ETC technology for precise calibration. Include automated gloss compensating technology for accurate color measurements. Their extensive storage capacity provides long-term data retention. Our Portable Spectrophotometer are equipped with a TFT touch screen, a built-in camera, and high-capacity rechargeable batteries.

Portable Spectrophotometer LSP-A30
  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • -Test angle

Portable Spectrophotometer LSP-A31

  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • 60°Test angle

Portable spectrophotometer LSP-A10

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Blue light enhanced sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Xenon Lamp Spectrophotometer

Labtron Xenon Lamp Spectrophotometer comes with a high-quality flashing Xenon lamp that requires no preheating and has a lifespan of 3 years. Their multiple work modes, including T, A, C, and E, offer exceptional flexibility for various types of measurements. They use imported silicon photodiode detectors for high sensitivity and stability. Our Xenon Lamp Spectrophotometer’s large sample chamber supports the attachment of optional accessories, enhancing adaptability.

Xenon Lamp Spectrophotometer LXLS-A13
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
Xenon Lamp Spectrophotometer LXLS-A10
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Xenon Lamp Spectrophotometer LXLS-A11

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 1 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Fluorescence Spectrophotometer

Labtron Fluorescence Spectrophotometer are built with sensitive signal detection technology and advanced optical systems. They offer impressive fluorescence detection limits and exceptional signal-to-noise ratios. With a dual beam ratio excitation light monitoring system, they ensure stable fluorescence signals. Our Fluorescence Spectrophotometer have built-in optical gates, which enable effective analysis of unstable samples.

Fluorescence Spectrophotometer LFS-A12

  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit
Fluorescence Spectrophotometer LFS-A10
  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit
Fluorescence Spectrophotometer LFS-A11
  • 150 W Xenon LampExcitation Source
  • 200 nm to 900 nmExcitation Wavelength
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmExcitation Slit
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmEmission Slit

NIR Spectrophotometer

Labtron NIR Spectrophotometer feature a high-quality PTFE reference module and polystyrene wavelength standard filter for exceptional accuracy. Their automatic reference calibration and monitoring wavelengths ensure stable and reliable measurements. They support transmission measurement mode. Their grating monochromator optical system ensures minimal stray light and noise. Our NIR Spectrophotometer features a USB port for easy data transfer and operates efficiently within a wide temperature and humidity range.

NIR Spectrophotometer LNIR-A10

  • 900 nm to 2500 nmWavelength Range
  • ≤ 0.2Wavelength Accuracy
  • ≤ 0.05Wavelength Reproducibility
  • 8 nmBandwidth