Visible Spectrophotometer LVS-A20

Visible Spectrophotometer LVS-A20 is single beam bench top device with 340 to 1000 nm wavelength range, and offers spectral bandwidth of 5 nm. Features with T, A, C photometric working mode and Czerny-Turner monochromator type unit. Designed with holographic blazed grating monochromator it has the advantage of high wavelength accuracy, good monochromaticity and low stray light. The high accuracy and good reproducibility and stability of measurement reading instrument.

  • Photometry Single Beam
    Monochromatic Type Czerny-Turner
    Wavelength range 340 to 1000nm
    Spectral bandwidth 5 nm
    Wavelength Accuracy ± 2nm
    Wavelength Repeatability ≤ 1 nm
    Focal length 160 mm
    Photometric Range 0 to 100.0 %T 0 to 1.999 A 0 to 1999 C
    Photometric Accuracy ± 0.5 % T
    Photometric Repeatability ≤ 0.2 % T
    Detector Silicon Photocell
    Grating 1200 lines/mm
    Stray light ≤ 0.1( at 360nm NaNo2 )
    Noise 100%(T)noise≤0.3%(T) , 0%(T) noise ≤0.2 %(T)
    Cuvette holder size 10 mm
    Dimension 580 × 460 × 345 mm
    Power consumption 80 W
    Power supply AC 220 V±22 V 50Hz ±1 Hz
    Gross weight 12.5 kg
    • The holographic blazed grating monochromator has the advantages of high wavelength accuracy, good monochromaticity and low stray light
    • Sample compartment for 5 to 50 mm cuvettes
    • Equipped with USB port and automatic zero, full scale adjustment
    • Automatic light gate technology to protect photoelectric sensors
    • Adopts microprocessor control technology, qualitative analysis of substances in the visible spectrum, High accuracy of measurement readings, good stability
    • Automatic light gate technology, no need blackbody, to protect the photoelectric sensor
  • Visible Spectrophotometer is used in high requirement for precision measurement in the research and production of organic chemistry, biochemistry, medical testing, food testing, environmental protection, water testing industries, etc.

  • Accessories no.Name Qty.
    1User manual1 pc
    2Glass cuvette 1cm 44 pcs
    4Power cable1 pc
    5Fuse2 pcs

Related Products of Visible Spectrophotometer

Labtron Visible Spectrophotometer feature high-resolution grating systems that cover a broad wavelength range. These instruments offer multiple modes, including transmittance, absorbance, concentration, and autocalibration. They utilize adaptable light sources and silicon photodiode detectors for precise measurements. Our visible spectrophotometers provide exceptional stability and precision, making them ideal for industrial applications and research.

Vis Spectrophotometer LVS-C10

  • 320 ~ 1100 nmWavelength Range
  • 4 nmSpectral Bandwidth
  • ± 0.5 nmWavelength Accuracy
  • ≤ 0.2 nmWavelength Repeatability

Vis Spectrophotometer LVS-B10

  • 325 ~ 1000 nmWavelength Range
  • AutomaticSetting Wavelength
  • 2 nmSpectral Bandwidth
  • ± 1.0 nmWavelength Accuracy

Visible Spectrophotometer LVS-A21

  • Single BeamPhotometry
  • Czerny-TurnerMonochromatic Type
  • 325 to 1000nmWavelength range
  • 2 nmSpectral bandwidth
Vis Spectrophotometer LVS-A10
  • 330 to 1000 nmWavelength Range
  • 5 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • ≤ 1.0 nmWavelength Repeatability
Vis Spectrophotometer LVS-A11
  • 335 ~ 1000 nmWavelength Range
  • 4 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • 1 nmWavelength Repeatability

Visible Spectrophotometer LVS-A30

  • 320 to 1100 nmWavelength range
  • 2.0 nmSpectral bandwidth
  • ± 0.8 nmWavelength Accuracy
  • ≤ 0.3 nmWavelength Repeatability

Vis Spectrophotometer LVS-C11

  • 320 ~ 1000 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.5 nmWavelength Accuracy
  • ≤ 0.2 nmWavelength Repeatability

Xenon Lamp Spectrophotometer

Labtron Xenon Lamp Spectrophotometer comes with a high-quality flashing Xenon lamp that requires no preheating and has a lifespan of 3 years. Their multiple work modes, including T, A, C, and E, offer exceptional flexibility for various types of measurements. They use imported silicon photodiode detectors for high sensitivity and stability. Our Xenon Lamp Spectrophotometer’s large sample chamber supports the attachment of optional accessories, enhancing adaptability.

Xenon Lamp Spectrophotometer LXLS-A13

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Xenon Lamp Spectrophotometer LXLS-A11

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 1 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
Xenon Lamp Spectrophotometer LXLS-A10
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Double Beam UV/Vis Spectrophotometer

Labtron Double Beam UV/Vis Spectrophotometer offer automatic wavelength adjustments with their silicon photodiode detectors. Their dual beam designs cover a broad wavelength range. They support multiple measurement methods to meet diverse analytical requirements. Our spectrophotometer ensures precise results and ease of use with auto calibration, user-friendly interfaces, and advanced optics.

Double Beam UV/Vis Spectrophotometer LUS-B30
  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Double Beam UV/Vis Spectrophotometer LUS-B32

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Double Beam UV/Vis Spectrophotometer LUS-B31

  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Portable Spectrophotometer

Labtron Portable Spectrophotometer utilize traditional whiteboards in their optical systems to ensure accurate measurements. They incorporate ETC technology for precise calibration. Include automated gloss compensating technology for accurate color measurements. Their extensive storage capacity provides long-term data retention. Our Portable Spectrophotometer are equipped with a TFT touch screen, a built-in camera, and high-capacity rechargeable batteries.

Portable spectrophotometer LSP-A10
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Blue light enhanced sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
Portable Spectrophotometer LSP-A31
  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • 60°Test angle

Portable Spectrophotometer LSP-A30

  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • -Test angle

Nano Spectrophotometer

Labtron Nano Spectrophotometer enables rapid analysis of small sample volumes and features a wide wavelength range for precise measurements. They ensure high repeatability in detecting micro-volume quantities of nucleic acids and other components. They include built-in computers with USB connections and user-friendly interfaces. Our Nano Spectrophotometer are Ideal for concentrated samples without the need for dilution or baseline adjustments.

Nano Spectrophotometer LNS-A10

  • 200 - 800 nmWavelength range
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)Path length
  • ± 1 nmWavelength accuracy
  • ≤ 3 nm (FWHM at Hg 546 nm)Wavelength Resolution
Nano Spectrophotometer LNS-B11
  • 230 nm, 260 nm, 280 nmWavelength range
  • 1.0 mm, 0.2 mmPath length
  • 0.3 - 2.0 µlMinimum Sample size
  • 0.2 - 75A (10 mm equivalent absorbance)Absorbance range
Nano Spectrophotometer LNS-A21
  • 200 - 850 nmWavelength range
  • 1 mm, 2 mm, 5 mm, 10 mmPath length
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution

Single Beam UV/Visible Spectrophotometer

Labtron Single Beam UV/Visible Spectrophotometer feature a wide range of wavelengths and multiple options for spectral bandwidth selection. They facilitate quantitative analysis and photometric measurements through intuitive interfaces. They offer flexibility with various installed light sources. Our Single Beam UV/Vis Spectrophotometer ensure high performance by incorporating automatic wavelength adjustment.

Single Beam UV/Vis Spectrophotometer LUS-A50

  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Vis Spectrophotometer LUS-A51

  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Single Beam UV/Vis Spectrophotometer LUS-A52
  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability