Single Beam UV/Vis Spectrophotometer LUS-A51 is bench top device with 190 nm to 1100 nm wavelength range, and offers spectral bandwidth of 1 nm. With T, A, C, E work mode it is designed with Hi, Med, Low (Max. 3000 nm/min) scanning speed range. The latest ARM system and long optical system ensure high accuracy and good stability of the instrument. The 10.1 inch TFT Touch colored display and it can perform powerful functions like Photometric measurement, Quantitative measurement, Kinetics, Spectrum scan, DNA/Protein test, Multi-wavelength test etc. This advance, high quality spectrophotometer supports USB data transfer and storage system.

  • Wavelength range 190 to 1100 nm
    Spectral bandwidth 1 nm
    Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
    Wavelength Repeatability ≤ 0.1 nm
    Optical system Single beam 1200 lines/mm
    Photometric Range 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F)
    Photometric Accuracy 0.2%T (0 to 100 %T), ±0.002A(0 to 0.5 A), ±0.004A (0.5 to 1 A)
    Photometric Repeatability ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A)
    Detector Imported silicon photodiode
    Light source Imported Deuterium and Tungsten lamp
    Stray light ≤ 0.03 % T @ 220 nm, 360 nm
    Stability ± 0.0005 A/h @ 500 nm
    Data Output Port USB drive, USB host, RS232
    Power supply AC 220 V, 50 Hz or 110 V, 60 Hz
    Noise 0.0005 A @ 500 nm
    Display 10.1 inches TFT colored capacitive touch screen
    Baseline flatness ± 0.001 A
    Printer port Parallel port
    Work mode T, A, C, E
    Scanning speed Hi, Med, Low (Max. 3000 nm/min)
    Wavelength setting Auto
    Cuvette holder 10 mm manual 4 cell holder
    Dimension 810 × 660 × 390 mm
    Gross weight 27 kg
    • Work mode T, A, C, E and scanning speed range Hi, Med, Low (Max. 3000 nm/min)
    • In-house massive memory is capable of saving up to 1024 M for test data & working curves
    • Designed with 10.1 inches high resolution TFT colored capacitive touch screen and windows Graphic interface
    • Large sample chamber can accommodate 5 to 100 mm cuvettes of all kinds
    • Equipped with powerful functions like Photometric measurement, Quantitative measurement, Kinetics, Spectrum scan, DNA/Protein test, Multi-wavelength test, etc
    • The USB port can be used for data transfer, which can easily exported to excel for further processing
    • Socket type deuterium and tungsten lamp can make lamps switching without optics debugging and easy to be replaced
  • Single Beam UV/Vis Spectrophotometer is used in high requirement for precision measurement in the research and production of organic chemistry, biochemistry, medical testing, food testing, environmental protection, water testing industries, etc.

  • Accessories no. Name
    110 mm glass cuvette × 4
    210 mm quartz cuvette × 2
    32, power cord
    4User manual
    5PC software

Related Products of Single Beam UV/Visible Spectrophotometer

Labtron Single Beam UV/Visible Spectrophotometer feature a wide range of wavelengths and multiple options for spectral bandwidth selection. They facilitate quantitative analysis and photometric measurements through intuitive interfaces. They offer flexibility with various installed light sources. Our Single Beam UV/Vis Spectrophotometer ensure high performance by incorporating automatic wavelength adjustment.

Single Beam UV/Visible Spectrophotometer LUS-A40

  • 190 ~ 1100 nmWavelength Range
  • 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nmSpectral Bandwidth
  • ± 0.3 nmWavelength Accuracy
  • 0.2 nmWavelength Repeatability

Single Beam UV/Visible Spectrophotometer LUS-A21

  • 190 ~ 1100 nmWavelength Range
  • AutomaticSetting Wavelength
  • 1.8 nmSpectral Bandwidth
  • ± 0.3 nmWavelength Accuracy

Single Beam UV/Visible Spectrophotometer LUS-A11

  • 190 ~ 1100 nmWavelength Range
  • 1.8 nmSpectral Bandwidth
  • ± 0.3 nmWavelength Accuracy
  • 0.2 nmWavelength Repeatability
Single Beam UV/Visible Spectrophotometer LUS-A10
  • 190 ~ 1100 nmWavelength Range
  • 1 nmSpectral Bandwidth
  • ± 0.3 nmWavelength Accuracy
  • 0.2 nmWavelength Repeatability
Single Beam UV/Vis Spectrophotometer LUS-A50
  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Visible Spectrophotometer LUS-A22

  • 190 ~ 1100 nmWavelength Range
  • 0.5 nm, 1 nm, 2 nm, 4 nm adjustableSpectral Bandwidth
  • ± 0.3 nmWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Visible Spectrophotometer LUS-A30

  • 190 ~ 1100 nmWavelength Range
  • AutomaticSetting Wavelength
  • 4 nmSpectral Bandwidth
  • ± 0.5 nmWavelength Accuracy

Single Beam UV/Visible Spectrophotometer LUS-A20

  • 190 ~ 1100 nmWavelength Range
  • AutomaticSetting Wavelength
  • 2 nmSpectral Bandwidth
  • ± 0.5 nmWavelength Accuracy
Single Beam UV/Vis Spectrophotometer LUS-A52
  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Single Beam UV-Vis Spectrophotometer LUS-C10
  • 200 to 1000 nmWavelength Range
  • 4.0 nmSpectral Bandwidth
  • Single beamOptical System
  • ±0.2 nmWavelength Accuracy

Single Beam UV/Visible Spectrophotometer

Labtron Single Beam UV/Visible Spectrophotometer feature a wide range of wavelengths and multiple options for spectral bandwidth selection. They facilitate quantitative analysis and photometric measurements through intuitive interfaces. They offer flexibility with various installed light sources. Our Single Beam UV/Vis Spectrophotometer ensure high performance by incorporating automatic wavelength adjustment.

Single Beam UV/Vis Spectrophotometer LUS-A51

  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Vis Spectrophotometer LUS-A52

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Single Beam UV/Vis Spectrophotometer LUS-A50
  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Table Top Spectrophotometer

Labtron Table Top Spectrophotometer features ETC technology ensuring real-time calibration for precise results. They support multiple measurement apertures, including options for small, medium, and large sample sizes. They also have specialized configurations for liquids and reflective materials. Their high-capacity rechargeable batteries provide long-lasting performance. Our Table Top Spectrophotometer offer a wide range of color spaces and color difference formulas catering to diverse application needs.

Table Top Spectrophotometer LTS-A16
  • 360 nm to 780 nmWavelength Range
  • 10 nmWavelength Pitch
  • Silicon Photodiode ArraySensor
  • Concave GratingGrating Method

Table top spectrophotometer LTS-A10

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination system
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Dual light path sensor arraySensor

Table Top Spectrophotometer LTS-A15

  • 400 nm to 700 nmWavelength Range
  • 10 nmWavelength Interval
  • High sensitivity silicon photodiodeSensor
  • LEDLight Source

Fluorescence Spectrophotometer

Labtron Fluorescence Spectrophotometer are built with sensitive signal detection technology and advanced optical systems. They offer impressive fluorescence detection limits and exceptional signal-to-noise ratios. With a dual beam ratio excitation light monitoring system, they ensure stable fluorescence signals. Our Fluorescence Spectrophotometer have built-in optical gates, which enable effective analysis of unstable samples.

Fluorescence Spectrophotometer LFS-A12
  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit
Fluorescence Spectrophotometer LFS-A11
  • 150 W Xenon LampExcitation Source
  • 200 nm to 900 nmExcitation Wavelength
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmExcitation Slit
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmEmission Slit

Fluorescence Spectrophotometer LFS-A10

  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit

Xenon Lamp Spectrophotometer

Labtron Xenon Lamp Spectrophotometer comes with a high-quality flashing Xenon lamp that requires no preheating and has a lifespan of 3 years. Their multiple work modes, including T, A, C, and E, offer exceptional flexibility for various types of measurements. They use imported silicon photodiode detectors for high sensitivity and stability. Our Xenon Lamp Spectrophotometer’s large sample chamber supports the attachment of optional accessories, enhancing adaptability.

Xenon Lamp Spectrophotometer LXLS-A13

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
Xenon Lamp Spectrophotometer LXLS-A11
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 1 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
Xenon Lamp Spectrophotometer LXLS-A10
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Nano Spectrophotometer

Labtron Nano Spectrophotometer enables rapid analysis of small sample volumes and features a wide wavelength range for precise measurements. They ensure high repeatability in detecting micro-volume quantities of nucleic acids and other components. They include built-in computers with USB connections and user-friendly interfaces. Our Nano Spectrophotometer are Ideal for concentrated samples without the need for dilution or baseline adjustments.

Nano Spectrophotometer LNS-A21

  • 200 - 850 nmWavelength range
  • 1 mm, 2 mm, 5 mm, 10 mmPath length
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution

Nano Spectrophotometer LNS-B11

  • 230 nm, 260 nm, 280 nmWavelength range
  • 1.0 mm, 0.2 mmPath length
  • 0.3 - 2.0 µlMinimum Sample size
  • 0.2 - 75A (10 mm equivalent absorbance)Absorbance range
Nano Spectrophotometer LNS-A10
  • 200 - 800 nmWavelength range
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)Path length
  • ± 1 nmWavelength accuracy
  • ≤ 3 nm (FWHM at Hg 546 nm)Wavelength Resolution