Single Beam UV/Visible Spectrophotometer LUS-A40

Single Beam UV/Vis Spectrophotometer is formulated with large LCD display screen and 4 cell holder capacity. It has full functionality from 190 – 1100 nm range of wavelength. It has wide range spectral bandwidth of 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm. This single beam spectrophotometer has highly stable optics with 1200 lines/mm grating. Spectrophotometer is complied using ISO/CE international standards. It is particularly designed to meet its versatility in research and industries.

  • Wavelength Range 190 ~ 1100 nm
    Setting Wavelength
    Spectral Bandwidth 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm
    Wavelength Accuracy ± 0.3 nm
    Wavelength Repeatability 0.2 nm
    Photometric Range 0 - 200 % T, (-0.3) to (-3.0)A, 0 - 9999 C
    Photometric Mode
    Photometric Accuracy ± 0.3 % T
    Photometric Repeatability 0.2 % T
    Transmittance accuracy
    Transmittance repeatability
    Detector Silicon Photodiode
    Light Source Deuterium & Tungsten Halogen Lamp
    Stray Light ≤ 0.05 % T at 220 nm, 360 nm
    Stability 0.002 A / h at 500 nm
    Data Output Port USB
    Power Requirement AC 220 V / 50 Hz, 110 V / 60 Hz.
    Dimensions
    Noise ± 0.001 A
    Weight
    Gross Weight
    Net Weight
    Power
    Display LCD Display resolution 320 × 240 Dots LCD
    Optical System Single Beam (1200 lines / mm grating)
    Baseline Linearity
    Baseline Drift
    Baseline Flatness ± 0.001 A
    Printer Port Parallel Port
    Packing Size 860 x 660 x 465 mm
    Software
    Packing Weight 35 kg
    • Single beam spectrophotometer
    • Wavelength range 190 nm to 1100 nm
    • Wide range of bandwidth 0.5 / 1.0 /2.0 / 4.0 / 5.0 nm with PC software
    • Optical system with 1200 lines / mm grating
    • 4 cell holder available along with USB port for data storage
    • 6 inches LCD display & integrated user interface
    • Extensive range of accessories available
  • Single Beam UV/Vis Spectrophotometer is ideal for quality control, general research, pharmaceuticals, biochemical and clinical laboratory applications.

Related Products of Single Beam UV/Visible Spectrophotometer

Labtron Single Beam UV/Visible Spectrophotometer feature a wide range of wavelengths and multiple options for spectral bandwidth selection. They facilitate quantitative analysis and photometric measurements through intuitive interfaces. They offer flexibility with various installed light sources. Our Single Beam UV/Vis Spectrophotometer ensure high performance by incorporating automatic wavelength adjustment.

Single Beam UV/Visible Spectrophotometer LUS-A21

  • 190 ~ 1100 nmWavelength Range
  • AutomaticSetting Wavelength
  • 1.8 nmSpectral Bandwidth
  • ± 0.3 nmWavelength Accuracy

Single Beam UV/Visible Spectrophotometer LUS-A30

  • 190 ~ 1100 nmWavelength Range
  • AutomaticSetting Wavelength
  • 4 nmSpectral Bandwidth
  • ± 0.5 nmWavelength Accuracy

Single Beam UV/Visible Spectrophotometer LUS-A10

  • 190 ~ 1100 nmWavelength Range
  • 1 nmSpectral Bandwidth
  • ± 0.3 nmWavelength Accuracy
  • 0.2 nmWavelength Repeatability
Single Beam UV/Visible Spectrophotometer LUS-A11
  • 190 ~ 1100 nmWavelength Range
  • 1.8 nmSpectral Bandwidth
  • ± 0.3 nmWavelength Accuracy
  • 0.2 nmWavelength Repeatability
Single Beam UV-Vis Spectrophotometer LUS-C10
  • 200 to 1000 nmWavelength Range
  • 4.0 nmSpectral Bandwidth
  • Single beamOptical System
  • ±0.2 nmWavelength Accuracy

Single Beam UV/Visible Spectrophotometer LUS-A20

  • 190 ~ 1100 nmWavelength Range
  • AutomaticSetting Wavelength
  • 2 nmSpectral Bandwidth
  • ± 0.5 nmWavelength Accuracy

Single Beam UV/Visible Spectrophotometer LUS-A22

  • 190 ~ 1100 nmWavelength Range
  • 0.5 nm, 1 nm, 2 nm, 4 nm adjustableSpectral Bandwidth
  • ± 0.3 nmWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Vis Spectrophotometer LUS-A52

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Single Beam UV/Vis Spectrophotometer LUS-A51
  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Single Beam UV/Vis Spectrophotometer LUS-A50
  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer designed for accurate elemental analysis. Each of them features integrated flame and graphite furnace atomization systems, automatic wavelength scanning, and peak searching capabilities. Safety alarms ensure secure operation. Our Atomic Absorption Spectrophotometer delivers reliable results across a wide range of wavelengths with precise optics and temperature control.

Atomic Absorption Spectrophotometer LAAS-A11

  • 190 - 900 nmWavelength range
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nmSpectral Bandwidth
  • ≤ ± 0.5 nmWavelength accuracy
  • ≤ 0.3 nm(single direction)Wavelength repeatability

Atomic Absorption Spectrophotometer LAAS-A13

  • 190 to 900 nmWorking spectral range
  • 0.1, 0.2, 0.4, 1.0 and 2.0 nmSpectral Bandwith
  • ± 0.15 nmWavelength accuracy
  • ≤ 0.04 nmWavelength repeatability
Atomic Absorption Spectrophotometer LAAS-A20
  • 180 - 900 nmWavelength range
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability

Visible Spectrophotometer

Labtron Visible Spectrophotometer feature high-resolution grating systems that cover a broad wavelength range. These instruments offer multiple modes, including transmittance, absorbance, concentration, and autocalibration. They utilize adaptable light sources and silicon photodiode detectors for precise measurements. Our visible spectrophotometers provide exceptional stability and precision, making them ideal for industrial applications and research.

Vis Spectrophotometer LVS-A11
  • 335 ~ 1000 nmWavelength Range
  • 4 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • 1 nmWavelength Repeatability

Vis Spectrophotometer LVS-A10

  • 330 to 1000 nmWavelength Range
  • 5 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • ≤ 1.0 nmWavelength Repeatability

Vis Spectrophotometer LVS-B10

  • 325 ~ 1000 nmWavelength Range
  • AutomaticSetting Wavelength
  • 2 nmSpectral Bandwidth
  • ± 1.0 nmWavelength Accuracy

Nano Spectrophotometer

Labtron Nano Spectrophotometer enables rapid analysis of small sample volumes and features a wide wavelength range for precise measurements. They ensure high repeatability in detecting micro-volume quantities of nucleic acids and other components. They include built-in computers with USB connections and user-friendly interfaces. Our Nano Spectrophotometer are Ideal for concentrated samples without the need for dilution or baseline adjustments.

Nano Spectrophotometer LNS-A10
  • 200 - 800 nmWavelength range
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)Path length
  • ± 1 nmWavelength accuracy
  • ≤ 3 nm (FWHM at Hg 546 nm)Wavelength Resolution
Nano Spectrophotometer LNS-A21
  • 200 - 850 nmWavelength range
  • 1 mm, 2 mm, 5 mm, 10 mmPath length
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution

Nano Spectrophotometer LNS-B11

  • 230 nm, 260 nm, 280 nmWavelength range
  • 1.0 mm, 0.2 mmPath length
  • 0.3 - 2.0 µlMinimum Sample size
  • 0.2 - 75A (10 mm equivalent absorbance)Absorbance range

Xenon Lamp Spectrophotometer

Labtron Xenon Lamp Spectrophotometer comes with a high-quality flashing Xenon lamp that requires no preheating and has a lifespan of 3 years. Their multiple work modes, including T, A, C, and E, offer exceptional flexibility for various types of measurements. They use imported silicon photodiode detectors for high sensitivity and stability. Our Xenon Lamp Spectrophotometer’s large sample chamber supports the attachment of optional accessories, enhancing adaptability.

Xenon Lamp Spectrophotometer LXLS-A11

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 1 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
Xenon Lamp Spectrophotometer LXLS-A13
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
Xenon Lamp Spectrophotometer LXLS-A10
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Portable Spectrophotometer

Labtron Portable Spectrophotometer utilize traditional whiteboards in their optical systems to ensure accurate measurements. They incorporate ETC technology for precise calibration. Include automated gloss compensating technology for accurate color measurements. Their extensive storage capacity provides long-term data retention. Our Portable Spectrophotometer are equipped with a TFT touch screen, a built-in camera, and high-capacity rechargeable batteries.

Portable Spectrophotometer LSP-A31

  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • 60°Test angle

Portable spectrophotometer LSP-A10

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Blue light enhanced sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
Portable Spectrophotometer LSP-A30
  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • -Test angle