Single Beam UV-Vis Spectrophotometer LUS-C10

Single Beam UV-Vis Spectrophotometer LUS-C10 is a compact, table top unit, comprising Silicon photodiode detector, Tungsten and Deuterium lamp as light source. Features 200 nm to 1000 nm wavelength range, 4.0 nm bandwidth with automatic setting of wavelength, direct input by K, B factor for quantitative measurement of standard curve. Designed with single chip microcomputer control, LCD screen to display multiple sets of data, large memory storage, it provides rich measurement methods with high performance and reliability.

  • Wavelength Range 200 to 1000 nm
    Spectral Bandwidth 4.0 nm
    Optical System Single beam
    Wavelength Accuracy ±0.2 nm
    Wavelength Repeatability 0.2 nm
    Wavelength Resolution 0.1 nm
    Photometric Display Range -4 to 4 A
    Photometric Mode T, A, C, E
    Photometric Accuracy ±0.2% τ
    Photometric Repeatability 0.2% τ
    Light Source Tungsten lamp, Deuterium lamp
    Stray Light ≤0.05% τ (220 nm NaI, 340 nm NaNO2)
    Stability 0.001 A/h @500 nm
    Noise ± 0.002 A @500 nm
    Display LCD display (128*64 dots)
    Baseline Flatness ± 0.001 A
    Detector Silicon photodiode
    Power Supply AC 220/110 V, 50/60 Hz
    Dimensions (L×W×H) 460×330×210 mm
    Net Weight 11 kg
    • Compact, table top, single beam designed UV-Vis spectrophotometer
    • Designed with silicon photodiode detector, tungsten and deuterium lamp as light source
    • Wide wavelength range of 200 nm to 1000 nm with automatic setting
    • LCD screen displays multiple sets of data
    • Maximum 10 point standard curve measurement function
    • Direct input by K, B factor for quantitative measurement of standard curve
    • Large memory space to store multiple sets of data and curve
    • Produce High performance and reliable results with user-friendly interface
  • Single Beam UV-Visible Spectrophotometer are used for analysis of band gap, optical coatings and thin films, quantitative analyses, kinetics, wavelength scanning, and DNA and Protein analysis across biological research, bio-industry, pharmaceutical analysis, pharmaceutical, teaching and research, environmental protection, food hygiene, clinical examination, health and epidemic prevention and other fields.

  • 1 cm quartz cuvette- 2 pcs
    1 cm glass cuvette- 4 pcs
    Dust cover- 1 pc
    Power line- 1 pc
    Instructional Manual- 1 pc

Related Products of Single Beam UV/Visible Spectrophotometer

Labtron Single Beam UV/Visible Spectrophotometer feature a wide range of wavelengths and multiple options for spectral bandwidth selection. They facilitate quantitative analysis and photometric measurements through intuitive interfaces. They offer flexibility with various installed light sources. Our Single Beam UV/Vis Spectrophotometer ensure high performance by incorporating automatic wavelength adjustment.

Single Beam UV/Vis Spectrophotometer LUS-A51

  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Visible Spectrophotometer LUS-A20

  • 190 ~ 1100 nmWavelength Range
  • AutomaticSetting Wavelength
  • 2 nmSpectral Bandwidth
  • ± 0.5 nmWavelength Accuracy

Single Beam UV/Visible Spectrophotometer LUS-A21

  • 190 ~ 1100 nmWavelength Range
  • AutomaticSetting Wavelength
  • 1.8 nmSpectral Bandwidth
  • ± 0.3 nmWavelength Accuracy
Single Beam UV/Visible Spectrophotometer LUS-A10
  • 190 ~ 1100 nmWavelength Range
  • 1 nmSpectral Bandwidth
  • ± 0.3 nmWavelength Accuracy
  • 0.2 nmWavelength Repeatability
Single Beam UV/Vis Spectrophotometer LUS-A50
  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Visible Spectrophotometer LUS-A30

  • 190 ~ 1100 nmWavelength Range
  • AutomaticSetting Wavelength
  • 4 nmSpectral Bandwidth
  • ± 0.5 nmWavelength Accuracy

Single Beam UV/Vis Spectrophotometer LUS-A52

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Visible Spectrophotometer LUS-A40

  • 190 ~ 1100 nmWavelength Range
  • 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nmSpectral Bandwidth
  • ± 0.3 nmWavelength Accuracy
  • 0.2 nmWavelength Repeatability
Single Beam UV/Visible Spectrophotometer LUS-A22
  • 190 ~ 1100 nmWavelength Range
  • 0.5 nm, 1 nm, 2 nm, 4 nm adjustableSpectral Bandwidth
  • ± 0.3 nmWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Single Beam UV/Visible Spectrophotometer LUS-A11
  • 190 ~ 1100 nmWavelength Range
  • 1.8 nmSpectral Bandwidth
  • ± 0.3 nmWavelength Accuracy
  • 0.2 nmWavelength Repeatability

NIR Spectrophotometer

Labtron NIR Spectrophotometer feature a high-quality PTFE reference module and polystyrene wavelength standard filter for exceptional accuracy. Their automatic reference calibration and monitoring wavelengths ensure stable and reliable measurements. They support transmission measurement mode. Their grating monochromator optical system ensures minimal stray light and noise. Our NIR Spectrophotometer features a USB port for easy data transfer and operates efficiently within a wide temperature and humidity range.

NIR Spectrophotometer LNIR-A10

  • 900 nm to 2500 nmWavelength Range
  • ≤ 0.2Wavelength Accuracy
  • ≤ 0.05Wavelength Reproducibility
  • 8 nmBandwidth

Visible Spectrophotometer

Labtron Visible Spectrophotometer feature high-resolution grating systems that cover a broad wavelength range. These instruments offer multiple modes, including transmittance, absorbance, concentration, and autocalibration. They utilize adaptable light sources and silicon photodiode detectors for precise measurements. Our visible spectrophotometers provide exceptional stability and precision, making them ideal for industrial applications and research.

Vis Spectrophotometer LVS-A11

  • 335 ~ 1000 nmWavelength Range
  • 4 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • 1 nmWavelength Repeatability
Vis Spectrophotometer LVS-B10
  • 325 ~ 1000 nmWavelength Range
  • AutomaticSetting Wavelength
  • 2 nmSpectral Bandwidth
  • ± 1.0 nmWavelength Accuracy
Vis Spectrophotometer LVS-A10
  • 330 to 1000 nmWavelength Range
  • 5 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • ≤ 1.0 nmWavelength Repeatability

Nano Spectrophotometer

Labtron Nano Spectrophotometer enables rapid analysis of small sample volumes and features a wide wavelength range for precise measurements. They ensure high repeatability in detecting micro-volume quantities of nucleic acids and other components. They include built-in computers with USB connections and user-friendly interfaces. Our Nano Spectrophotometer are Ideal for concentrated samples without the need for dilution or baseline adjustments.

Nano Spectrophotometer LNS-B11

  • 230 nm, 260 nm, 280 nmWavelength range
  • 1.0 mm, 0.2 mmPath length
  • 0.3 - 2.0 µlMinimum Sample size
  • 0.2 - 75A (10 mm equivalent absorbance)Absorbance range

Nano Spectrophotometer LNS-A10

  • 200 - 800 nmWavelength range
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)Path length
  • ± 1 nmWavelength accuracy
  • ≤ 3 nm (FWHM at Hg 546 nm)Wavelength Resolution
Nano Spectrophotometer LNS-A21
  • 200 - 850 nmWavelength range
  • 1 mm, 2 mm, 5 mm, 10 mmPath length
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution

Single Beam UV/Visible Spectrophotometer

Labtron Single Beam UV/Visible Spectrophotometer feature a wide range of wavelengths and multiple options for spectral bandwidth selection. They facilitate quantitative analysis and photometric measurements through intuitive interfaces. They offer flexibility with various installed light sources. Our Single Beam UV/Vis Spectrophotometer ensure high performance by incorporating automatic wavelength adjustment.

Single Beam UV/Vis Spectrophotometer LUS-A51
  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Vis Spectrophotometer LUS-A50

  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Vis Spectrophotometer LUS-A52

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Portable Spectrophotometer

Labtron Portable Spectrophotometer utilize traditional whiteboards in their optical systems to ensure accurate measurements. They incorporate ETC technology for precise calibration. Include automated gloss compensating technology for accurate color measurements. Their extensive storage capacity provides long-term data retention. Our Portable Spectrophotometer are equipped with a TFT touch screen, a built-in camera, and high-capacity rechargeable batteries.

Portable Spectrophotometer LSP-A30
  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • -Test angle
Portable Spectrophotometer LSP-A31
  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • 60°Test angle

Portable spectrophotometer LSP-A10

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Blue light enhanced sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere