Atomic Absorption Spectrophotometer LAAS-A11

Atomic absorption spectrophotometer comes with Deuterium lamp for background correction, RS232 interface, Multi-linear and nonlinear curve fitting. Its double beam system automatically compensates the light source drift and wavelength drift caused by the variation of temperature and electronic circuit drift so as to reach a good basic line stability. The specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration in this atomic absorption spectrophotometer. It has multiple applications in research and development and industrial analysis.

  • Monochromator
    Wavelength range 190 - 900 nm
    Spectral Bandwidth 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
    Wavelength accuracy ≤ ± 0.5 nm
    Wavelength repeatability ≤ 0.3 nm(single direction)
    Baseline drift ± 0.004 Abs / 30 min
    Grating groove density
    Sample Volume
    The volume of sample
    Repeated Sampling Frequency
    Cleaning and waste container volume
    Absorbance Range
    The Program
    Temperature Range
    Detector
    Heating Mode
    Temperature Control Method
    Temperature Control
    Resolution < 40 %
    Lamp holder
    Lamp current adjustment range
    Lamp power supply mode
    Optical System
    Atomization Chamber
    Characteristics Volume
    Characteristic concentration (Cu) ≤ 0.04 mg / ml / 1 %
    Detection Limit
    Detection Limit (Cu) 0.008 mg/ml
    Background calibration ability Greater than 30 times
    Burner
    Nebulizer
    Precision
    Ignition Type
    Sprayer
    Room Spray
    Sample Tray
    The Smallest Lincrement
    Safety measures
    Gas Control
    Measurement
    Concentration calculation
    The Cooling Water
    The number of repeated measurements
    Print results
    Software Environment
    Operating temperature
    Working humidity
    Power supply 220 V / 3 A, 50 Hz
    Power (VAC)
    Gross Weight 160 kg
    Weight
    Dimension (L × W × H) 1220 x 770 x 730 mm
    • Double Beam system to compensate the light source drift and wavelength drift
    • Build-in computer data processing and LCD display
    • No pre-heating of Cathode lamp for a long time to analyze the sample
    • High precision of measurement
    • Multi-functional analysis mode
    • Fast analysis of sample
    • High energy optical path
    • Safe and reliable gas path system
    • Electronic circuit drift to reach a good basic line stability
  • Atomic absorption spectrophotometer is used to analyze elements in agriculture, chemical, environmental study, food, mining, and petrochemical, pharmaceutical industries.

  • A graphite furnace system
    Titanium burner—5cm
    Nitrous oxide generator
    Hydride generator
    Graphite tubes
    Acetylene regulator
    Nitrous oxide regulator Software
    Recirculating cooling water system

Related Products of Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer designed for accurate elemental analysis. Each of them features integrated flame and graphite furnace atomization systems, automatic wavelength scanning, and peak searching capabilities. Safety alarms ensure secure operation. Our Atomic Absorption Spectrophotometer delivers reliable results across a wide range of wavelengths with precise optics and temperature control.

Atomic Absorption Spectrophotometer LAAS-A22

  • 180 – 900 nmWavelength range
  • 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic settingSpectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability

Atomic Absorption Spectrophotometer LAAS-A13

  • 190 to 900 nmWorking spectral range
  • 0.1, 0.2, 0.4, 1.0 and 2.0 nmSpectral Bandwith
  • ± 0.15 nmWavelength accuracy
  • ≤ 0.04 nmWavelength repeatability

Flame Atomic Absorption Spectrophotometer LAAS-A12

  • 190 nm ~ 900 nmWavelength range
  • 0.1 nm, 0.2 nm, 1.0 nm, 2.0 nmSpectral bandwidth
  • ± 0.25 nmWavelength accuracy
  • 0.15 nmWavelength repeatability
Atomic Absorption Spectrophotometer LAAS-A21
  • 180 – 900 nmWavelength range
  • 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability
Atomic Absorption Spectrophotometer LAAS-A20
  • 180 - 900 nmWavelength range
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability

NIR Spectrophotometer

Labtron NIR Spectrophotometer feature a high-quality PTFE reference module and polystyrene wavelength standard filter for exceptional accuracy. Their automatic reference calibration and monitoring wavelengths ensure stable and reliable measurements. They support transmission measurement mode. Their grating monochromator optical system ensures minimal stray light and noise. Our NIR Spectrophotometer features a USB port for easy data transfer and operates efficiently within a wide temperature and humidity range.

NIR Spectrophotometer LNIR-A10

  • 900 nm to 2500 nmWavelength Range
  • ≤ 0.2Wavelength Accuracy
  • ≤ 0.05Wavelength Reproducibility
  • 8 nmBandwidth

Xenon Lamp Spectrophotometer

Labtron Xenon Lamp Spectrophotometer comes with a high-quality flashing Xenon lamp that requires no preheating and has a lifespan of 3 years. Their multiple work modes, including T, A, C, and E, offer exceptional flexibility for various types of measurements. They use imported silicon photodiode detectors for high sensitivity and stability. Our Xenon Lamp Spectrophotometer’s large sample chamber supports the attachment of optional accessories, enhancing adaptability.

Xenon Lamp Spectrophotometer LXLS-A13

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
Xenon Lamp Spectrophotometer LXLS-A10
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
Xenon Lamp Spectrophotometer LXLS-A11
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 1 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Double Beam UV/Vis Spectrophotometer

Labtron Double Beam UV/Vis Spectrophotometer offer automatic wavelength adjustments with their silicon photodiode detectors. Their dual beam designs cover a broad wavelength range. They support multiple measurement methods to meet diverse analytical requirements. Our spectrophotometer ensures precise results and ease of use with auto calibration, user-friendly interfaces, and advanced optics.

Double Beam UV/Vis Spectrophotometer LUS-B30

  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Double Beam UV/Vis Spectrophotometer LUS-B32

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Double Beam UV/Vis Spectrophotometer LUS-B31
  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Table Top Spectrophotometer

Labtron Table Top Spectrophotometer features ETC technology ensuring real-time calibration for precise results. They support multiple measurement apertures, including options for small, medium, and large sample sizes. They also have specialized configurations for liquids and reflective materials. Their high-capacity rechargeable batteries provide long-lasting performance. Our Table Top Spectrophotometer offer a wide range of color spaces and color difference formulas catering to diverse application needs.

Table Top Spectrophotometer LTS-A16
  • 360 nm to 780 nmWavelength Range
  • 10 nmWavelength Pitch
  • Silicon Photodiode ArraySensor
  • Concave GratingGrating Method

Table Top Spectrophotometer LTS-A15

  • 400 nm to 700 nmWavelength Range
  • 10 nmWavelength Interval
  • High sensitivity silicon photodiodeSensor
  • LEDLight Source

Table top spectrophotometer LTS-A10

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination system
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Dual light path sensor arraySensor

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer designed for accurate elemental analysis. Each of them features integrated flame and graphite furnace atomization systems, automatic wavelength scanning, and peak searching capabilities. Safety alarms ensure secure operation. Our Atomic Absorption Spectrophotometer delivers reliable results across a wide range of wavelengths with precise optics and temperature control.

Atomic Absorption Spectrophotometer LAAS-A20
  • 180 - 900 nmWavelength range
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability
Atomic Absorption Spectrophotometer LAAS-A13
  • 190 to 900 nmWorking spectral range
  • 0.1, 0.2, 0.4, 1.0 and 2.0 nmSpectral Bandwith
  • ± 0.15 nmWavelength accuracy
  • ≤ 0.04 nmWavelength repeatability

Atomic Absorption Spectrophotometer LAAS-A11

  • 190 - 900 nmWavelength range
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nmSpectral Bandwidth
  • ≤ ± 0.5 nmWavelength accuracy
  • ≤ 0.3 nm(single direction)Wavelength repeatability