Atomic Absorption Spectrophotometer LAAS-A13

Flame Atomic Absorption Spectrophotometer LAAS-A13 is a microprocessor controlled instrument based on analysis of metal ions by flame and graphite furnace atomizer with their absorption at wavelength of 190 to 900 nm. Czerny-Turner monochromator and variance of bandwidth provides user flexibility. It is provided with deuterium hollow cathode lamp to exclude interference of molecular absorption and Titanium Burner to increase the analysis efficiency and precision of flame. Its double beam radiation sources enables good basic line stability. Graphic analysis system provides data on analysis of entire process e.g. measured value, temperature, procedures, time, etc. It has great applications in research, medicine, environmental science and other industries.

  • Working spectral range 190 to 900 nm
    Spectral Bandwith 0.1, 0.2, 0.4, 1.0 and 2.0 nm
    Wavelength accuracy ± 0.15 nm
    Wavelength repeatability ≤ 0.04 nm
    Baseline stability ≤ 0.002 Abs / 30 min
    Characteristic concentration of copper 0.02 μg / ml / 1 %
    Detection limit of copper 0.004 μg / ml
    Measurement Repeatability 0.005
    Grating 1800 lines / mm
    Inflamer All-metal titanium burner
    Atomizer Efficient glass atomizer
    Lamp stand 8 lamps automatic turret, automatic alignment
    D2 Background calibration ability 1 A ≤ 30 times correction ability
    Dimensions 700 × 550 × 450 mm
    Net weight 75 Kg
    Power supply 220 V ± 22 V AC
    Acetylene air burner 100 mm
    Ignition dynamic baseline drift ≤ 0.006 Abs / 30 min
    Characteristic viscocity ≤ 0.025 μg / ml / 1 %
    Standard deviation of the accuracy ≤ 0.5 % (Cu, absorbance > 0.8 A) (detection limit Cu ≤ 0.008 μg / ml)
    Protection system Can inevitably cut off gas if pressure is low, power cut-off, flame out and alteration of the burner
    • Integrated flame/graphite furnace atomization system, changeable with flame emission burner
    • Turret for 8 pre-aligned Hollow Cathode Lamps fitted with pre-heating, and individual pre-centred lamps
    • PID and Dual curve mode light-controlled temperature control technique ensures fast heating and analytical sensitivity
    • Fully automated wavelength scanning and peak searching
    • Advance software for complete parameter settings
    • Reliable fully automatic graphite furnace analysis
    • Alarm feature to protect fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system
    • Analysis of elements by flame absorption method and emission method
    • Strong database system which possesses more than 500 data self-storage
    • Results printed as parameter, data result and diagram
  • It is suitable to analyse trace amount of element from mixture, also in forensics and chemistry, biological science to detect toxic elements from blood and drug samples.

  • Accessories no. Name
    1 PC workstation
    2 Printer
    3 Oil free Air compressor
    4 Acetylene reducing valve
    5 Cu - Hollow cathode lamp
    6 Air filter
  • GRAPHITE FURNACE
    Maximum temperature 3000 ℃
    Temperature increasing speed ≥ 2000 ℃ / S
    Characteristic quantity (Cd) ≤ 0.5 × 10 to 12g , (Cu) ≤ 0.5 × 10 to 11g
    Accuracy (Cu) ≤3 % , (Cd) ≤ 3 %
    Dimension 550 × 450 × 300 mm
    Net weight 65 Kg
    Safety system Protection for Overload current, reduced air pressure, low cooling water flow
    Power supply 220 V ± 22 V AC, 7000 W

Related Products of Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer designed for accurate elemental analysis. Each of them features integrated flame and graphite furnace atomization systems, automatic wavelength scanning, and peak searching capabilities. Safety alarms ensure secure operation. Our Atomic Absorption Spectrophotometer delivers reliable results across a wide range of wavelengths with precise optics and temperature control.

Atomic Absorption Spectrophotometer LAAS-A22

  • 180 – 900 nmWavelength range
  • 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic settingSpectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability

Atomic Absorption Spectrophotometer LAAS-A11

  • 190 - 900 nmWavelength range
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nmSpectral Bandwidth
  • ≤ ± 0.5 nmWavelength accuracy
  • ≤ 0.3 nm(single direction)Wavelength repeatability

Atomic Absorption Spectrophotometer LAAS-A20

  • 180 - 900 nmWavelength range
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability
Flame Atomic Absorption Spectrophotometer LAAS-A12
  • 190 nm ~ 900 nmWavelength range
  • 0.1 nm, 0.2 nm, 1.0 nm, 2.0 nmSpectral bandwidth
  • ± 0.25 nmWavelength accuracy
  • 0.15 nmWavelength repeatability
Atomic Absorption Spectrophotometer LAAS-A21
  • 180 – 900 nmWavelength range
  • 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability

Xenon Lamp Spectrophotometer

Labtron Xenon Lamp Spectrophotometer comes with a high-quality flashing Xenon lamp that requires no preheating and has a lifespan of 3 years. Their multiple work modes, including T, A, C, and E, offer exceptional flexibility for various types of measurements. They use imported silicon photodiode detectors for high sensitivity and stability. Our Xenon Lamp Spectrophotometer’s large sample chamber supports the attachment of optional accessories, enhancing adaptability.

Xenon Lamp Spectrophotometer LXLS-A11

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 1 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Xenon Lamp Spectrophotometer LXLS-A10

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
Xenon Lamp Spectrophotometer LXLS-A13
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Double Beam UV/Vis Spectrophotometer

Labtron Double Beam UV/Vis Spectrophotometer offer automatic wavelength adjustments with their silicon photodiode detectors. Their dual beam designs cover a broad wavelength range. They support multiple measurement methods to meet diverse analytical requirements. Our spectrophotometer ensures precise results and ease of use with auto calibration, user-friendly interfaces, and advanced optics.

Double Beam UV/Vis Spectrophotometer LUS-B32
  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Double Beam UV/Vis Spectrophotometer LUS-B31

  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Double Beam UV/Vis Spectrophotometer LUS-B30

  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Visible Spectrophotometer

Labtron Single Beam UV/Visible Spectrophotometer feature a wide range of wavelengths and multiple options for spectral bandwidth selection. They facilitate quantitative analysis and photometric measurements through intuitive interfaces. They offer flexibility with various installed light sources. Our Single Beam UV/Vis Spectrophotometer ensure high performance by incorporating automatic wavelength adjustment.

Single Beam UV/Vis Spectrophotometer LUS-A52
  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Single Beam UV/Vis Spectrophotometer LUS-A50
  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Vis Spectrophotometer LUS-A51

  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Portable Spectrophotometer

Labtron Portable Spectrophotometer utilize traditional whiteboards in their optical systems to ensure accurate measurements. They incorporate ETC technology for precise calibration. Include automated gloss compensating technology for accurate color measurements. Their extensive storage capacity provides long-term data retention. Our Portable Spectrophotometer are equipped with a TFT touch screen, a built-in camera, and high-capacity rechargeable batteries.

Portable spectrophotometer LSP-A10

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Blue light enhanced sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
Portable Spectrophotometer LSP-A31
  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • 60°Test angle
Portable Spectrophotometer LSP-A30
  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • -Test angle

Fluorescence Spectrophotometer

Labtron Fluorescence Spectrophotometer are built with sensitive signal detection technology and advanced optical systems. They offer impressive fluorescence detection limits and exceptional signal-to-noise ratios. With a dual beam ratio excitation light monitoring system, they ensure stable fluorescence signals. Our Fluorescence Spectrophotometer have built-in optical gates, which enable effective analysis of unstable samples.

Fluorescence Spectrophotometer LFS-A11

  • 150 W Xenon LampExcitation Source
  • 200 nm to 900 nmExcitation Wavelength
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmExcitation Slit
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmEmission Slit

Fluorescence Spectrophotometer LFS-A12

  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit
Fluorescence Spectrophotometer LFS-A10
  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit