Double Beam UV-Vis Spectrophotometer LUS-B12

Double Beam UV-Vis Spectrophotometer LUS-B12 is a compact, tabletop split double beam designed UV-Vis spectrophotometer, comprising automatic calibration and silicon photocell sensors. Features automatic 8-pool sample holder with 4 quartz cuvette, offers 190 to 1100 nm of wavelength range with C-T monochromator and 1200 L/mm holographic grating. Equipped with deuterium lamp and tungsten lamp as light source, it provides high-resolution, low stray light, and lasting stability. With LCD display, Windows based PC control software and USB interface, this spectrometer can meet the multi-level analysis application requirements of users.

  • Wavelength Range 190 to 1100 nm
    Spectral Bandwidth 1.8 nm
    Optical System Split double beam, C-T monochromator,1200 L/mm holographic grating
    Wavelength Accuracy ±0.5nm
    Wavelength Repeatability 0.2 nm
    Wavelength Resolution 0.1 nm
    Wavelength Calibration Automatic calibration after starting up
    Measuring Range 0 to 200% T, -0.301 to 4.000 Abs, -9999 to 9999C, -9999 to 9999 F
    Transmittance Accuracy ±0.3% T
    Transmittance Repeatability 0.1% T
    Light Source Tungsten lamp, Deuterium lamp
    Stray Light ≤0.05% T @ 220 nm,360 nm
    Light Switching Point 294 nm to 365 nm (adjustable)
    Display 128×64 mm Blue LCD display
    Baseline Flatness ≤±0.002 Abs (With UV-Solution software)
    Baseline Drift ≤0.001 Abs / half hour (after warm-up at 500 nm)
    Sample Holder Automatic 8-pool sample holder
    Cuvette 4 Quartz cuvette (10 mm optical path)
    Sensor Silicon photocell
    Interface USB
    PC Software Yes
    Power Supply 220V ± 10% 50 Hz, 85 VA / 110 V ± 10% 60 Hz 85 VA
    Dimensions (L×W×H) 540×445×230 mm
    Package Dimension (L×W×H) 660×560×400 mm
    Net Weight 17 kg
    Gross Weight 26 kg
    • Split double beam designed UV-Vis spectrophotometer
    • Automatic calibration and silicon photocell sensors
    • Automatic 8-pool sample holder
    • 4 quartz cuvette of 10 mm optical path
    • 190 to 1100 nm of wavelength range with C-T monochromator and 1200 L/mm holographic grating
    • Deuterium lamp and tungsten lamp as light source
    • LCD display, Windows based PC control software and USB interface
    • Provides high-resolution, low stray light, and lasting stability
  • Double Beam UV-Vis Spectrophotometer is used for photometric measurement, spectrum scan, quantitative determination, dynamics measurement, 3D map measurement, multi-wavelength test, DNA/ Protein concentration measurement etc. across factories, schools, metallurgy, agriculture, food industry, biochemistry, environment protection, petrochemical industry, medical and health and scientific research institutes or labs etc.

Related Products of Double Beam UV/Vis Spectrophotometer

Labtron Double Beam UV/Vis Spectrophotometer offer automatic wavelength adjustments with their silicon photodiode detectors. Their dual beam designs cover a broad wavelength range. They support multiple measurement methods to meet diverse analytical requirements. Our spectrophotometer ensures precise results and ease of use with auto calibration, user-friendly interfaces, and advanced optics.

Double Beam UV/Vis Spectrophotometer LUS-B31

  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Double Beam UV-Vis Spectrophotometer LUS-B13

  • 190 to 1100 nmWavelength Range
  • 1.0 nmSpectral Bandwidth
  • Double beamOptical System
  • ±0.3 nmWavelength Accuracy

Double Beam UV/Vis Spectrophotometer LUS-B32

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Double Beam UV-Vis Spectrophotometer LUS-B11
  • 190 to 1100 nmWavelength range
  • 1.8 nmSpectral bandwidth
  • Double beam; 1200 lines/mm gratingOptical system
  • ±0.1nm (D2 656.1nm), ±0.3nm @ allWavelength accuracy
Double Beam UV-Vis Spectrophotometer LUS-B40
  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4 nmSpectral bandwidth
  • ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full rangeWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Double Beam UV/Vis Spectrophotometer LUS-B30

  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Double Beam UV-Vis Spectrophotometer LUS-B10

  • 190 to 1100 nmWavelength Range
  • 1.8 nmSpectral Bandwidth
  • Double beamOptical System
  • ±0.3 nmWavelength Accuracy

Double beam UV-Visible Spectrophotometer LUS-B15

  • 190 ~ 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • 0.5 nmWavelength accuracy
  • ≤ 0.2 nmWavelength repeatability
Double Beam UV/Vis Spectrophotometer LUS-B16
  • 190 ~ 1100 nmWavelength Range
  • AutomaticSetting Wavelength
  • 0.5 / 1.0 / 2.0 / 4.0 nm adjustableSpectral Bandwidth
  • ± 0.3 nmWavelength Accuracy
Double Beam UV-Vis Spectrophotometer LUS-B20
  • 190 to 1100 nmWavelength range
  • 1.0 to 5.0 nm (adjustable)Spectral bandwidth
  • Double beam, C-T monochromator, 1600 L/mm holographic gratingOptical system
  • ±0.3 nmWavelength accuracy

Xenon Lamp Spectrophotometer

Labtron Xenon Lamp Spectrophotometer comes with a high-quality flashing Xenon lamp that requires no preheating and has a lifespan of 3 years. Their multiple work modes, including T, A, C, and E, offer exceptional flexibility for various types of measurements. They use imported silicon photodiode detectors for high sensitivity and stability. Our Xenon Lamp Spectrophotometer’s large sample chamber supports the attachment of optional accessories, enhancing adaptability.

Xenon Lamp Spectrophotometer LXLS-A13

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Xenon Lamp Spectrophotometer LXLS-A10

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
Xenon Lamp Spectrophotometer LXLS-A11
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 1 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Nano Spectrophotometer

Labtron Nano Spectrophotometer enables rapid analysis of small sample volumes and features a wide wavelength range for precise measurements. They ensure high repeatability in detecting micro-volume quantities of nucleic acids and other components. They include built-in computers with USB connections and user-friendly interfaces. Our Nano Spectrophotometer are Ideal for concentrated samples without the need for dilution or baseline adjustments.

Nano Spectrophotometer LNS-B11
  • 230 nm, 260 nm, 280 nmWavelength range
  • 1.0 mm, 0.2 mmPath length
  • 0.3 - 2.0 µlMinimum Sample size
  • 0.2 - 75A (10 mm equivalent absorbance)Absorbance range

Nano Spectrophotometer LNS-A10

  • 200 - 800 nmWavelength range
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)Path length
  • ± 1 nmWavelength accuracy
  • ≤ 3 nm (FWHM at Hg 546 nm)Wavelength Resolution

Nano Spectrophotometer LNS-A21

  • 200 - 850 nmWavelength range
  • 1 mm, 2 mm, 5 mm, 10 mmPath length
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution

Double Beam UV/Vis Spectrophotometer

Labtron Double Beam UV/Vis Spectrophotometer offer automatic wavelength adjustments with their silicon photodiode detectors. Their dual beam designs cover a broad wavelength range. They support multiple measurement methods to meet diverse analytical requirements. Our spectrophotometer ensures precise results and ease of use with auto calibration, user-friendly interfaces, and advanced optics.

Double Beam UV/Vis Spectrophotometer LUS-B30
  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Double Beam UV/Vis Spectrophotometer LUS-B32
  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Double Beam UV/Vis Spectrophotometer LUS-B31

  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Visible Spectrophotometer

Labtron Single Beam UV/Visible Spectrophotometer feature a wide range of wavelengths and multiple options for spectral bandwidth selection. They facilitate quantitative analysis and photometric measurements through intuitive interfaces. They offer flexibility with various installed light sources. Our Single Beam UV/Vis Spectrophotometer ensure high performance by incorporating automatic wavelength adjustment.

Single Beam UV/Vis Spectrophotometer LUS-A50

  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Single Beam UV/Vis Spectrophotometer LUS-A52
  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Single Beam UV/Vis Spectrophotometer LUS-A51
  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer designed for accurate elemental analysis. Each of them features integrated flame and graphite furnace atomization systems, automatic wavelength scanning, and peak searching capabilities. Safety alarms ensure secure operation. Our Atomic Absorption Spectrophotometer delivers reliable results across a wide range of wavelengths with precise optics and temperature control.

Atomic Absorption Spectrophotometer LAAS-A20

  • 180 - 900 nmWavelength range
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability

Atomic Absorption Spectrophotometer LAAS-A13

  • 190 to 900 nmWorking spectral range
  • 0.1, 0.2, 0.4, 1.0 and 2.0 nmSpectral Bandwith
  • ± 0.15 nmWavelength accuracy
  • ≤ 0.04 nmWavelength repeatability
Atomic Absorption Spectrophotometer LAAS-A11
  • 190 - 900 nmWavelength range
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nmSpectral Bandwidth
  • ≤ ± 0.5 nmWavelength accuracy
  • ≤ 0.3 nm(single direction)Wavelength repeatability