Multi purpose Pocket pH tester LPPT-B10

The multipurpose pocket pH tester LPPM-B10 comes with BNC connector, it can be connected to different pH electrode for different applications. With (-1.00) to 15.00 pH measurement range, 1 - 3 points calibration system and manual temperature compensation mode, this multi-purpose pocket pH tester can measure pH , temperature over wide range with accuracy. Its built–in system menu can customize five functional parameters as per requirement.

  • pH measurement range pH range: (-1.00) to 15.00 pH
    Shape of electrode Different electrodes can be connceted via BNC Connector
    pH measurement accuracy ± 0.01 pH
    Calibration point 1 - 3 points
    Calibration solution USA (pH 4.0/7.00/10.01)
    Operating temperature
    Temperature accuracy
    Temperature compensation range 0 °C to 100 °C , Manual
    Data hold function Manual or Automatic
    Connector BNC
    Shutdown mode
    Dimension (length × diameter) 175 × 40 mm
    Weight 100 g
    Power type 2 × 1.5 V AAA batteries
    Battery life About 200 hours
    • 1 - 3 point calibration , automatic identification of calibration buffers
    • Manual mode for temperature compensation ensures high precision measurement results
    • Auto hold function freezes stable, final readings for better viewing and recording
    • Automatic power off to reduce battery power consumption
    • Reset function automatically resumes all the setting back to factory default options
    • Alarm icon to indicate low battery
    • Built-in system menu, customizable
    • Reset function to restore settings to default mode
    • Waterproof performance to maintain integrity of the instrument
  • The multipurpose pocket pH tester can be used in water and waste water analysis, aquaculture & environmental monitoring, food & beverage industry & other indusries.

  • pH electrode
    pH buffer solutions (pH 4.01/7.00/10.01)
    Carrying case
    AAA Batteries
  • pH electrodes to measure pH of liquids and semi-solids , solvents
    pH standard buffer USA (pH 4.01/7.00/10.01), NIST (pH 4.01/6.86/9.18)

Related Products of pH Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket pH tester LPPT-A21

  • pH range: (-1.00) to 15.00 pHpH measurement range
  • Flat pH electrodeShape of electrode
  • ± 0.01 pHpH measurement accuracy
  • 1 - 3 pointsCalibration point

Pocket pH tester LPPT-A31

  • pH range: (-1.00) to 15.00 pHpH measurement range
  • Flat pH electrodeShape of electrode
  • ± 0.01 pHpH measurement accuracy
  • 1 - 3 pointsCalibration point

Pocket pH tester LPPT-A12

  • 0.0 - 14.00 pHpH measurement range
  • Long distance planar pH electrodeShape of electrode
  • ± 0.1 pHpH measurement accuracy
  • 2 pointsCalibration point
Pocket pH tester LPPT-A10
  • 0.0 - 14.00 pHpH measurement range
  • Round glass pH electrodeShape of electrode
  • ± 0.1 pHpH measurement accuracy
  • 2 pointsCalibration point
Pocket pH tester LPPT-A11
  • 0.0 - 14.00 pHpH measurement range
  • Flat pH electrodeShape of electrode
  • ± 0.1 pHpH measurement accuracy
  • 2 pointsCalibration point

Pocket pH tester LPPT-A22

  • pH range: (-1.00) to 15.00 pHpH measurement range
  • Long distance planar pH electrodeShape of electrode
  • ± 0.01 pHpH measurement accuracy
  • 1 - 3 pointsCalibration point

Pocket pH tester LPPT-A30

  • pH range: (-1.00) to 15.00 pHpH measurement range
  • Round glass pH electrodeShape of electrode
  • ± 0.01 pHpH measurement accuracy
  • 1 - 3 pointsCalibration point

Pocket pH tester LPPT-A32

  • pH range: (-1.00) to 15.00 pHpH measurement range
  • Long distance planar pH electrodeShape of electrode
  • ± 0.01 pHpH measurement accuracy
  • 1 - 3 pointsCalibration point
Pocket pH tester LPPT-A20
  • pH range: (-1.00) to 15.00 pHpH measurement range
  • Round glass pH electrodeShape of electrode
  • ± 0.01 pHpH measurement accuracy
  • 1 - 3 pointsCalibration point

Portable Dissolve Oxygen Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable Dissolved oxygen meter LPRDO-A10

  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.5 mg / LDissolved oxygen accuracy
  • 0.1 mg / LResolution
  • 1 - 2 pointsCalibration points

Portable dissolved oxygen meter LPRDO-A11

  • 0.0 - 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.2 mg / LDissolved oxygen accuracy
  • 0.01 mg / LResolution
  • 1 - 2 pointsCalibration points
Online Conductivity Controller LOCC-A10
  • 0.01 to 20.00, 200.0, 2000 µS/ cm, 20.00, 200.0 mS/ cmConductivity measurement range
  • 1 to 3 pointsConductivity calibration points
  • ±1 % F.S.Conductivity accuracy
  • 0.001/ 0.01/ 0.1/ 1Conductivity resolution
Portable Conductivity Meter LPCM-A10
  • {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 3 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}Conductivity
  • {"Temperature measuring range":"0 105 \u00b0C, 32 to 221 \u00b0F","Temperature measuring accuracy":"\u00b1 \u00b00.5 C, \u00b1 0.9 \u00b0F","Temperature calibration points":"1 point","Temperature resolution":"0.1 \u00b0C, 0.1 \u00b0F"}Temperature
  • 0 to 100 °C, 32 to 212 ° F, Manual or AutomaticTemperature compensation
  • LinearTemperature coefficient

Portable Conductivity Meter LPCM-A11

  • {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 5 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}Conductivity
  • {"TDS range":"0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)","TDS accuracy":"\u00b11 % F.S","TDS factor":"0.01 to 1.00 (Default 0.5)","TDS resolution":"0.01, 0.1, 1"}TDS
  • {"Temperature measuring range":"0 105 \u00b0C, 32 to 221 \u00b0F","Temperature measuring accuracy":"\u00b1 \u00b00.5 C, \u00b1 0.9 \u00b0F","Temperature calibration points":"1 point","Temperature resolution":"0.1 \u00b0C, 0.1 \u00b0F"}Temperature
  • 0 to 100 °C, 32 to 212 ° F, Manual or AutomaticTemperature compensation

Portable Conductivity Meter LPCM-A12

  • {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 5 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}Conductivity
  • {"Salinity range":"0.00 to 80.00 ppt, 0.00 to 42.00 psu","Salinity accuracy":"\u00b11% F.S","Salinity measurement modes":"Practical Salinity (psu) or Natural Seawater (ppt)","Salinity resolution":"0.01, 0.1, 1"}Salinity
  • {"Temperature measuring range":"0 105 \u00b0C, 32 to 221 \u00b0F","Temperature measuring accuracy":"\u00b1 \u00b00.5 C, \u00b1 0.9 \u00b0F","Temperature calibration points":"1 point","Temperature resolution":"0.1 \u00b0C, 0.1 \u00b0F"}Temperature
  • 0 to 100 °C, 32 to 212 ° F, Manual or AutomaticTemperature compensation

Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Conductivity Meter LBCM-A14
  • {"Conductivity measurement range":"0.01-20.0, 200.0, 2000 \u00b5S\/cm, 20.00, 200.0 mS\/cm","Conductivity accuracy":"\u00b11% F.S.","Conductivity resolution":"0.001, 0.01, 0.1, 1","Conductivity calibration points":"1 to 3 points","Conductivity calibration solutions":"10 \u00b5S\/cm , 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm"}Conductivity Mode
  • {"TDS measurement Range":"0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)","TDS Accuracy":"\u00b1 1 % F.S.","TDS Factor":"0.01 to 1.00 (default 0.5)","TDS Calibration points":"3 points"}TDS Mode
  • {"Temperature range":"0 to 105\u00b0C, 32 to 221\u00b0F","Temperature accuracy":"\u00b11\u00b0C","Temperature resolution":"0.1\u00b0C, 0.1\u00b0F","Temperature calibration points":"1 point","Temperature Compensation Range and Mode":"Manual or Automatic, 0 to 100\u00b0C , 32 to 212\u00b0F","Temperature coefficient":"0.0 to 10.0 % per \u00b0C"}Temperature Mode
  • K=0.1, 1, 10Cell constant
Benchtop conductivity meter LBCM-A11
  • 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cmConductivity measurement range
  • ± 1 % F.S.Conductivity accuracy
  • 0.01, 0.1, 1Conductivity resolution
  • 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cmConductivity calibration solutions

Benchtop Conductivity Meter LBCM-A13

  • 0.000 μS/cm to 3000mS/cmConductivity measurement range
  • 5.00 Ω·cm to 100.0 MΩ·cmResistivity measurement range
  • 0.000 mg/L to 1000g/LTDS measurement range
  • 0.00 to 8.00 %Salinity measurement range

BOD Meter LBOD-A10

  • 0 to 35 mg/L, 0 to 70 mg/ L, 0 to 350 mg/L, 0 to 700 mg/L (without dilution)
    0 to 4000 mg/ L (need to dilute) (subsection measurement)
    Determination range
  • Less or less than 10 %Measurement error
  • 1 to 6Sample container/ bottle quantity
  • 1000 mlSample container/ bottle Capacity